Cargando…
Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients
Introduction The radiotherapy of left-sided breast cancers is challenging because of neighboring critical organs, posing an increased risk of complications. Various radiation delivery techniques have been used to deliver the desired dose of radiation to the target area while keeping the doses to nea...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286429/ https://www.ncbi.nlm.nih.gov/pubmed/34285843 http://dx.doi.org/10.7759/cureus.15732 |
_version_ | 1783723728841998336 |
---|---|
author | Waheed, Asmara Butt, Sumera Ishtiaq, Ali Mansha, Muhammad Atif Mehreen, Sana Raza, Mohsin Yousaf, Muhammad |
author_facet | Waheed, Asmara Butt, Sumera Ishtiaq, Ali Mansha, Muhammad Atif Mehreen, Sana Raza, Mohsin Yousaf, Muhammad |
author_sort | Waheed, Asmara |
collection | PubMed |
description | Introduction The radiotherapy of left-sided breast cancers is challenging because of neighboring critical organs, posing an increased risk of complications. Various radiation delivery techniques have been used to deliver the desired dose of radiation to the target area while keeping the doses to nearby structures within constraints. The main aim of this study is to quantify doses delivered to the organs at risk (OARs) including heart, left lung, spinal cord, and contralateral breast, and to the planning target volume (PTV) using Field-in-Field (FIF) and Volumetric Modulated Arc Therapy (VMAT). Patients and methods A retrospective review of 15 left-sided breast cancer patients was done. All the patients underwent breast-conserving surgery and adjuvant radiation. For every patient, two different radiation treatment plans were formulated and compared for the PTV coverage and doses to OARs, including heart, ipsilateral lung, spinal cord, and contralateral breast. The radiation treatment techniques utilized for this purpose were FIF and VMAT. The homogeneity index (HI), and conformity index (CI) required for the treatment planning were also calculated. Data was analyzed using Statistical Package for the Social Sciences (IBM Corp., Armonk, USA). An Independent T-test was used for statistical analysis. Results The mean age was 41 years and the majority of them were stage II. Total nine patients were given 4005centi Gray (cGy) in 15 fractions (fr) followed by 10Gy boost, hence receiving a total dose of 5005cGy in 20fr. While remaining six patients were given a total dose 4005cGy in 15fr without any boost. All patients were hypofractionated and the dose was delivered at a rate of 267cGy per fr. The FIF technique utilized in breast cancer radiation significantly reduced the mean doses to OARs: mean heart dose (3.81cGy), ipsilateral lung dose (V16- 15cGy), mean contralateral breast dose (0.03cGy), and maximum spinal cord dose (0.18cGy); as compared to VMAT technique which delivered comparatively higher doses: mean heart dose (8.85cGy), ipsilateral lung dose (V16- 19.82cGy), mean contralateral breast dose (4.59cGy), and maximum spinal cord dose (7.14cGy). There was a significant mean difference between doses of OARs and all p-values were statistically significant (p<0.005). Moreover, the FIF technique also improves the dose distribution of PTV in terms of dose homogeneity. However, the conformity index is more enhanced with VMAT as opposed to FIF. Conclusion The FIF technique is more advantageous than the VMAT planning technique because it provides better dose distribution in terms of PTV coverage and significantly lower doses to OARs in radiotherapy to left-sided breast cancer. |
format | Online Article Text |
id | pubmed-8286429 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-82864292021-07-19 Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients Waheed, Asmara Butt, Sumera Ishtiaq, Ali Mansha, Muhammad Atif Mehreen, Sana Raza, Mohsin Yousaf, Muhammad Cureus Radiation Oncology Introduction The radiotherapy of left-sided breast cancers is challenging because of neighboring critical organs, posing an increased risk of complications. Various radiation delivery techniques have been used to deliver the desired dose of radiation to the target area while keeping the doses to nearby structures within constraints. The main aim of this study is to quantify doses delivered to the organs at risk (OARs) including heart, left lung, spinal cord, and contralateral breast, and to the planning target volume (PTV) using Field-in-Field (FIF) and Volumetric Modulated Arc Therapy (VMAT). Patients and methods A retrospective review of 15 left-sided breast cancer patients was done. All the patients underwent breast-conserving surgery and adjuvant radiation. For every patient, two different radiation treatment plans were formulated and compared for the PTV coverage and doses to OARs, including heart, ipsilateral lung, spinal cord, and contralateral breast. The radiation treatment techniques utilized for this purpose were FIF and VMAT. The homogeneity index (HI), and conformity index (CI) required for the treatment planning were also calculated. Data was analyzed using Statistical Package for the Social Sciences (IBM Corp., Armonk, USA). An Independent T-test was used for statistical analysis. Results The mean age was 41 years and the majority of them were stage II. Total nine patients were given 4005centi Gray (cGy) in 15 fractions (fr) followed by 10Gy boost, hence receiving a total dose of 5005cGy in 20fr. While remaining six patients were given a total dose 4005cGy in 15fr without any boost. All patients were hypofractionated and the dose was delivered at a rate of 267cGy per fr. The FIF technique utilized in breast cancer radiation significantly reduced the mean doses to OARs: mean heart dose (3.81cGy), ipsilateral lung dose (V16- 15cGy), mean contralateral breast dose (0.03cGy), and maximum spinal cord dose (0.18cGy); as compared to VMAT technique which delivered comparatively higher doses: mean heart dose (8.85cGy), ipsilateral lung dose (V16- 19.82cGy), mean contralateral breast dose (4.59cGy), and maximum spinal cord dose (7.14cGy). There was a significant mean difference between doses of OARs and all p-values were statistically significant (p<0.005). Moreover, the FIF technique also improves the dose distribution of PTV in terms of dose homogeneity. However, the conformity index is more enhanced with VMAT as opposed to FIF. Conclusion The FIF technique is more advantageous than the VMAT planning technique because it provides better dose distribution in terms of PTV coverage and significantly lower doses to OARs in radiotherapy to left-sided breast cancer. Cureus 2021-06-18 /pmc/articles/PMC8286429/ /pubmed/34285843 http://dx.doi.org/10.7759/cureus.15732 Text en Copyright © 2021, Waheed et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Radiation Oncology Waheed, Asmara Butt, Sumera Ishtiaq, Ali Mansha, Muhammad Atif Mehreen, Sana Raza, Mohsin Yousaf, Muhammad Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients |
title | Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients |
title_full | Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients |
title_fullStr | Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients |
title_full_unstemmed | Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients |
title_short | Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients |
title_sort | dosimetric comparison of whole breast radiotherapy using field-in-field and volumetric modulated arc therapy techniques in left-sided breast cancer patients |
topic | Radiation Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286429/ https://www.ncbi.nlm.nih.gov/pubmed/34285843 http://dx.doi.org/10.7759/cureus.15732 |
work_keys_str_mv | AT waheedasmara dosimetriccomparisonofwholebreastradiotherapyusingfieldinfieldandvolumetricmodulatedarctherapytechniquesinleftsidedbreastcancerpatients AT buttsumera dosimetriccomparisonofwholebreastradiotherapyusingfieldinfieldandvolumetricmodulatedarctherapytechniquesinleftsidedbreastcancerpatients AT ishtiaqali dosimetriccomparisonofwholebreastradiotherapyusingfieldinfieldandvolumetricmodulatedarctherapytechniquesinleftsidedbreastcancerpatients AT manshamuhammadatif dosimetriccomparisonofwholebreastradiotherapyusingfieldinfieldandvolumetricmodulatedarctherapytechniquesinleftsidedbreastcancerpatients AT mehreensana dosimetriccomparisonofwholebreastradiotherapyusingfieldinfieldandvolumetricmodulatedarctherapytechniquesinleftsidedbreastcancerpatients AT razamohsin dosimetriccomparisonofwholebreastradiotherapyusingfieldinfieldandvolumetricmodulatedarctherapytechniquesinleftsidedbreastcancerpatients AT yousafmuhammad dosimetriccomparisonofwholebreastradiotherapyusingfieldinfieldandvolumetricmodulatedarctherapytechniquesinleftsidedbreastcancerpatients |