Cargando…

Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma

PURPOSE: To evaluate the magnitude of change in optic disc, peripapillary retinal nerve fiber layer (RNFL) and macular parameters measured by swept-source optical coherence tomography (SS-OCT) in glaucomatous eyes after filtration surgery, and to determine any possible relationship between these mea...

Descripción completa

Detalles Bibliográficos
Autores principales: Vessani, Roberto, Frota, Thalyta, Shigetomi, Gabriella, Correa, Priscila, Mariottoni, Eduardo B, Tavares, Ivan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286732/
https://www.ncbi.nlm.nih.gov/pubmed/34285468
http://dx.doi.org/10.2147/OPTH.S317190
_version_ 1783723774689935360
author Vessani, Roberto
Frota, Thalyta
Shigetomi, Gabriella
Correa, Priscila
Mariottoni, Eduardo B
Tavares, Ivan
author_facet Vessani, Roberto
Frota, Thalyta
Shigetomi, Gabriella
Correa, Priscila
Mariottoni, Eduardo B
Tavares, Ivan
author_sort Vessani, Roberto
collection PubMed
description PURPOSE: To evaluate the magnitude of change in optic disc, peripapillary retinal nerve fiber layer (RNFL) and macular parameters measured by swept-source optical coherence tomography (SS-OCT) in glaucomatous eyes after filtration surgery, and to determine any possible relationship between these measurements and baseline factors. PATIENTS AND METHODS: This multicenter, prospective, consecutive observational study included patients with open-angle glaucoma who required glaucoma filtering surgery (surgical group, 29 eyes) and those with stable disease (control group, 25 eyes). Patients from the surgical group underwent measurement of optic disc, peripapillary retinal nerve fiber layer (RNFL) and macular parameters before and after surgery. RESULTS: In the surgical group, there was a significant increase in rim area and a significant decrease in the linear cup/disc ratio, vertical cup/disc ratio and cup volume 1 and 2 months postoperatively (p< 0.05). No significant change in the mean RNFL thickness and also sectorial measurements were observed from baseline to 1 and 2 months after surgery (p>0.05). Furthermore, significant increases in macular parameters were observed until 2 months after surgery (p<0.05). No significant changes were observed for all SS-OCT measurements in the control group. There was a significant correlation between the magnitude of the structural measurements change and the IOP reduction for two topographic parameters (rim area and linear cup-disc ratio) and macular average thickness 1 month and 2 months postoperatively. CONCLUSION: In open-angle glaucoma patients submitted to surgical IOP reductions, improvements in topographic and macular OCT parameters measured by SS-OCT were observed for at least 2 months.
format Online
Article
Text
id pubmed-8286732
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-82867322021-07-19 Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma Vessani, Roberto Frota, Thalyta Shigetomi, Gabriella Correa, Priscila Mariottoni, Eduardo B Tavares, Ivan Clin Ophthalmol Original Research PURPOSE: To evaluate the magnitude of change in optic disc, peripapillary retinal nerve fiber layer (RNFL) and macular parameters measured by swept-source optical coherence tomography (SS-OCT) in glaucomatous eyes after filtration surgery, and to determine any possible relationship between these measurements and baseline factors. PATIENTS AND METHODS: This multicenter, prospective, consecutive observational study included patients with open-angle glaucoma who required glaucoma filtering surgery (surgical group, 29 eyes) and those with stable disease (control group, 25 eyes). Patients from the surgical group underwent measurement of optic disc, peripapillary retinal nerve fiber layer (RNFL) and macular parameters before and after surgery. RESULTS: In the surgical group, there was a significant increase in rim area and a significant decrease in the linear cup/disc ratio, vertical cup/disc ratio and cup volume 1 and 2 months postoperatively (p< 0.05). No significant change in the mean RNFL thickness and also sectorial measurements were observed from baseline to 1 and 2 months after surgery (p>0.05). Furthermore, significant increases in macular parameters were observed until 2 months after surgery (p<0.05). No significant changes were observed for all SS-OCT measurements in the control group. There was a significant correlation between the magnitude of the structural measurements change and the IOP reduction for two topographic parameters (rim area and linear cup-disc ratio) and macular average thickness 1 month and 2 months postoperatively. CONCLUSION: In open-angle glaucoma patients submitted to surgical IOP reductions, improvements in topographic and macular OCT parameters measured by SS-OCT were observed for at least 2 months. Dove 2021-07-14 /pmc/articles/PMC8286732/ /pubmed/34285468 http://dx.doi.org/10.2147/OPTH.S317190 Text en © 2021 Vessani et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Vessani, Roberto
Frota, Thalyta
Shigetomi, Gabriella
Correa, Priscila
Mariottoni, Eduardo B
Tavares, Ivan
Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma
title Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma
title_full Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma
title_fullStr Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma
title_full_unstemmed Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma
title_short Structural Changes in the Optic Disc and Macula Detected by Swept-Source Optical Coherence Tomography After Surgical Intraocular Pressure Reduction in Patients with Open-Angle Glaucoma
title_sort structural changes in the optic disc and macula detected by swept-source optical coherence tomography after surgical intraocular pressure reduction in patients with open-angle glaucoma
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286732/
https://www.ncbi.nlm.nih.gov/pubmed/34285468
http://dx.doi.org/10.2147/OPTH.S317190
work_keys_str_mv AT vessaniroberto structuralchangesintheopticdiscandmaculadetectedbysweptsourceopticalcoherencetomographyaftersurgicalintraocularpressurereductioninpatientswithopenangleglaucoma
AT frotathalyta structuralchangesintheopticdiscandmaculadetectedbysweptsourceopticalcoherencetomographyaftersurgicalintraocularpressurereductioninpatientswithopenangleglaucoma
AT shigetomigabriella structuralchangesintheopticdiscandmaculadetectedbysweptsourceopticalcoherencetomographyaftersurgicalintraocularpressurereductioninpatientswithopenangleglaucoma
AT correapriscila structuralchangesintheopticdiscandmaculadetectedbysweptsourceopticalcoherencetomographyaftersurgicalintraocularpressurereductioninpatientswithopenangleglaucoma
AT mariottonieduardob structuralchangesintheopticdiscandmaculadetectedbysweptsourceopticalcoherencetomographyaftersurgicalintraocularpressurereductioninpatientswithopenangleglaucoma
AT tavaresivan structuralchangesintheopticdiscandmaculadetectedbysweptsourceopticalcoherencetomographyaftersurgicalintraocularpressurereductioninpatientswithopenangleglaucoma