Transcatheter Caval Valve Implantation of the Tricento Valve for Tricuspid Regurgitation Using Advanced Intraprocedural Imaging
A 75-year-old patient with previous mitral and tricuspid reconstruction experienced severe tricuspid regurgitation. On the basis of a prohibitive surgical risk, an interventional heterotopic tricuspid valve implantation was planned. Implantation was performed using fusion-imaging, which facilitated...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8288622/ https://www.ncbi.nlm.nih.gov/pubmed/34316918 http://dx.doi.org/10.1016/j.jaccas.2019.11.020 |
Sumario: | A 75-year-old patient with previous mitral and tricuspid reconstruction experienced severe tricuspid regurgitation. On the basis of a prohibitive surgical risk, an interventional heterotopic tricuspid valve implantation was planned. Implantation was performed using fusion-imaging, which facilitated intraprocedural navigation. At 6-month follow-up, the patient presented in improved condition with reduced symptoms. (Level of Difficulty: Advanced.) |
---|