Cargando…
Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance
OBJECTIVE: To explore the quantitative adjustment of ablation index (AI) under different baseline impedance to achieve similar lesion dimensions. METHODS: (1) Keeping the AIs relatively constant, the lesion dimensions in different baseline impedances were studied. (2) According to Joule's law,...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8289601/ https://www.ncbi.nlm.nih.gov/pubmed/34336272 http://dx.doi.org/10.1155/2021/5574125 |
_version_ | 1783724322399977472 |
---|---|
author | Cai, Zheng Li, Sainan Zhang, Qi Wang, Chenyuan Jin, Zhen Fu, Ming Zhang, Shuai Liang, Ming Wang, Zulu Han, Yaling |
author_facet | Cai, Zheng Li, Sainan Zhang, Qi Wang, Chenyuan Jin, Zhen Fu, Ming Zhang, Shuai Liang, Ming Wang, Zulu Han, Yaling |
author_sort | Cai, Zheng |
collection | PubMed |
description | OBJECTIVE: To explore the quantitative adjustment of ablation index (AI) under different baseline impedance to achieve similar lesion dimensions. METHODS: (1) Keeping the AIs relatively constant, the lesion dimensions in different baseline impedances were studied. (2) According to Joule's law, Q = I(2)RT, keeping the current (I) unchanged, the powers corresponding to different baseline impedances can be obtained. Under different baseline impedances and corresponding powers, the swine hearts were ablated for 30 s in simulated human circumstances. The baseline impedances, the lesion dimensions, and AIs were recorded. And the derivation of empirical formula was achieved according to the AIs and baseline impedance values in similar lesions dimension. (3) Basic AI and baseline impedance (AI(0)/R(0)) were set as 400/120 Ω in the common AI groups and 550/120 Ω in the high AI groups, AI values in different baseline impedances were calculated using the empirical formula, and the corresponding lesion dimensions were measured to verify this formula. RESULTS: (1) Higher baseline impedances were related to smaller lesion dimensions at similar AIs. (2) The lesion dimensions were roughly the same after modulating the baseline impedance and power to keep the electric current relatively constant. The relationship between AI and R fitted with experimental data is AI = 1.9933R + 203.61 (r = 0.9649), and the formula derived is ΔAI = (AI(0) − 203)/R(0) × ΔR. (3) Under the guidance of the empirical formula, there was no significant difference in lesion dimensions between the standard group and the formula guiding groups when AI(0) = 400, but there was a shrinking tendence when AI > 700. CONCLUSION: The lesion depths are negatively correlated with baseline impedance at a certain AI. The relationship between baseline impedance and AI is “ΔAI = (AI(0) − 203)/R(0) × ΔR”. It is verified that when the AI is not too high, the empirical formula can be used to guide the quantitative adjustment of AIs at different baseline impedance, and the lesion depths achieved are roughly the same. |
format | Online Article Text |
id | pubmed-8289601 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-82896012021-07-31 Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance Cai, Zheng Li, Sainan Zhang, Qi Wang, Chenyuan Jin, Zhen Fu, Ming Zhang, Shuai Liang, Ming Wang, Zulu Han, Yaling Cardiol Res Pract Research Article OBJECTIVE: To explore the quantitative adjustment of ablation index (AI) under different baseline impedance to achieve similar lesion dimensions. METHODS: (1) Keeping the AIs relatively constant, the lesion dimensions in different baseline impedances were studied. (2) According to Joule's law, Q = I(2)RT, keeping the current (I) unchanged, the powers corresponding to different baseline impedances can be obtained. Under different baseline impedances and corresponding powers, the swine hearts were ablated for 30 s in simulated human circumstances. The baseline impedances, the lesion dimensions, and AIs were recorded. And the derivation of empirical formula was achieved according to the AIs and baseline impedance values in similar lesions dimension. (3) Basic AI and baseline impedance (AI(0)/R(0)) were set as 400/120 Ω in the common AI groups and 550/120 Ω in the high AI groups, AI values in different baseline impedances were calculated using the empirical formula, and the corresponding lesion dimensions were measured to verify this formula. RESULTS: (1) Higher baseline impedances were related to smaller lesion dimensions at similar AIs. (2) The lesion dimensions were roughly the same after modulating the baseline impedance and power to keep the electric current relatively constant. The relationship between AI and R fitted with experimental data is AI = 1.9933R + 203.61 (r = 0.9649), and the formula derived is ΔAI = (AI(0) − 203)/R(0) × ΔR. (3) Under the guidance of the empirical formula, there was no significant difference in lesion dimensions between the standard group and the formula guiding groups when AI(0) = 400, but there was a shrinking tendence when AI > 700. CONCLUSION: The lesion depths are negatively correlated with baseline impedance at a certain AI. The relationship between baseline impedance and AI is “ΔAI = (AI(0) − 203)/R(0) × ΔR”. It is verified that when the AI is not too high, the empirical formula can be used to guide the quantitative adjustment of AIs at different baseline impedance, and the lesion depths achieved are roughly the same. Hindawi 2021-07-12 /pmc/articles/PMC8289601/ /pubmed/34336272 http://dx.doi.org/10.1155/2021/5574125 Text en Copyright © 2021 Zheng Cai et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Cai, Zheng Li, Sainan Zhang, Qi Wang, Chenyuan Jin, Zhen Fu, Ming Zhang, Shuai Liang, Ming Wang, Zulu Han, Yaling Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance |
title | Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance |
title_full | Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance |
title_fullStr | Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance |
title_full_unstemmed | Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance |
title_short | Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance |
title_sort | derivation and verification of the relationship between ablation index and baseline impedance |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8289601/ https://www.ncbi.nlm.nih.gov/pubmed/34336272 http://dx.doi.org/10.1155/2021/5574125 |
work_keys_str_mv | AT caizheng derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT lisainan derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT zhangqi derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT wangchenyuan derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT jinzhen derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT fuming derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT zhangshuai derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT liangming derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT wangzulu derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance AT hanyaling derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance |