Cargando…

Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance

OBJECTIVE: To explore the quantitative adjustment of ablation index (AI) under different baseline impedance to achieve similar lesion dimensions. METHODS: (1) Keeping the AIs relatively constant, the lesion dimensions in different baseline impedances were studied. (2) According to Joule's law,...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Zheng, Li, Sainan, Zhang, Qi, Wang, Chenyuan, Jin, Zhen, Fu, Ming, Zhang, Shuai, Liang, Ming, Wang, Zulu, Han, Yaling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8289601/
https://www.ncbi.nlm.nih.gov/pubmed/34336272
http://dx.doi.org/10.1155/2021/5574125
_version_ 1783724322399977472
author Cai, Zheng
Li, Sainan
Zhang, Qi
Wang, Chenyuan
Jin, Zhen
Fu, Ming
Zhang, Shuai
Liang, Ming
Wang, Zulu
Han, Yaling
author_facet Cai, Zheng
Li, Sainan
Zhang, Qi
Wang, Chenyuan
Jin, Zhen
Fu, Ming
Zhang, Shuai
Liang, Ming
Wang, Zulu
Han, Yaling
author_sort Cai, Zheng
collection PubMed
description OBJECTIVE: To explore the quantitative adjustment of ablation index (AI) under different baseline impedance to achieve similar lesion dimensions. METHODS: (1) Keeping the AIs relatively constant, the lesion dimensions in different baseline impedances were studied. (2) According to Joule's law, Q = I(2)RT, keeping the current (I) unchanged, the powers corresponding to different baseline impedances can be obtained. Under different baseline impedances and corresponding powers, the swine hearts were ablated for 30 s in simulated human circumstances. The baseline impedances, the lesion dimensions, and AIs were recorded. And the derivation of empirical formula was achieved according to the AIs and baseline impedance values in similar lesions dimension. (3) Basic AI and baseline impedance (AI(0)/R(0)) were set as 400/120 Ω in the common AI groups and 550/120 Ω in the high AI groups, AI values in different baseline impedances were calculated using the empirical formula, and the corresponding lesion dimensions were measured to verify this formula. RESULTS: (1) Higher baseline impedances were related to smaller lesion dimensions at similar AIs. (2) The lesion dimensions were roughly the same after modulating the baseline impedance and power to keep the electric current relatively constant. The relationship between AI and R fitted with experimental data is AI = 1.9933R + 203.61 (r = 0.9649), and the formula derived is ΔAI = (AI(0) − 203)/R(0) × ΔR. (3) Under the guidance of the empirical formula, there was no significant difference in lesion dimensions between the standard group and the formula guiding groups when AI(0) = 400, but there was a shrinking tendence when AI > 700. CONCLUSION: The lesion depths are negatively correlated with baseline impedance at a certain AI. The relationship between baseline impedance and AI is “ΔAI = (AI(0) − 203)/R(0) × ΔR”. It is verified that when the AI is not too high, the empirical formula can be used to guide the quantitative adjustment of AIs at different baseline impedance, and the lesion depths achieved are roughly the same.
format Online
Article
Text
id pubmed-8289601
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-82896012021-07-31 Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance Cai, Zheng Li, Sainan Zhang, Qi Wang, Chenyuan Jin, Zhen Fu, Ming Zhang, Shuai Liang, Ming Wang, Zulu Han, Yaling Cardiol Res Pract Research Article OBJECTIVE: To explore the quantitative adjustment of ablation index (AI) under different baseline impedance to achieve similar lesion dimensions. METHODS: (1) Keeping the AIs relatively constant, the lesion dimensions in different baseline impedances were studied. (2) According to Joule's law, Q = I(2)RT, keeping the current (I) unchanged, the powers corresponding to different baseline impedances can be obtained. Under different baseline impedances and corresponding powers, the swine hearts were ablated for 30 s in simulated human circumstances. The baseline impedances, the lesion dimensions, and AIs were recorded. And the derivation of empirical formula was achieved according to the AIs and baseline impedance values in similar lesions dimension. (3) Basic AI and baseline impedance (AI(0)/R(0)) were set as 400/120 Ω in the common AI groups and 550/120 Ω in the high AI groups, AI values in different baseline impedances were calculated using the empirical formula, and the corresponding lesion dimensions were measured to verify this formula. RESULTS: (1) Higher baseline impedances were related to smaller lesion dimensions at similar AIs. (2) The lesion dimensions were roughly the same after modulating the baseline impedance and power to keep the electric current relatively constant. The relationship between AI and R fitted with experimental data is AI = 1.9933R + 203.61 (r = 0.9649), and the formula derived is ΔAI = (AI(0) − 203)/R(0) × ΔR. (3) Under the guidance of the empirical formula, there was no significant difference in lesion dimensions between the standard group and the formula guiding groups when AI(0) = 400, but there was a shrinking tendence when AI > 700. CONCLUSION: The lesion depths are negatively correlated with baseline impedance at a certain AI. The relationship between baseline impedance and AI is “ΔAI = (AI(0) − 203)/R(0) × ΔR”. It is verified that when the AI is not too high, the empirical formula can be used to guide the quantitative adjustment of AIs at different baseline impedance, and the lesion depths achieved are roughly the same. Hindawi 2021-07-12 /pmc/articles/PMC8289601/ /pubmed/34336272 http://dx.doi.org/10.1155/2021/5574125 Text en Copyright © 2021 Zheng Cai et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Cai, Zheng
Li, Sainan
Zhang, Qi
Wang, Chenyuan
Jin, Zhen
Fu, Ming
Zhang, Shuai
Liang, Ming
Wang, Zulu
Han, Yaling
Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance
title Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance
title_full Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance
title_fullStr Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance
title_full_unstemmed Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance
title_short Derivation and Verification of the Relationship between Ablation Index and Baseline Impedance
title_sort derivation and verification of the relationship between ablation index and baseline impedance
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8289601/
https://www.ncbi.nlm.nih.gov/pubmed/34336272
http://dx.doi.org/10.1155/2021/5574125
work_keys_str_mv AT caizheng derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT lisainan derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT zhangqi derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT wangchenyuan derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT jinzhen derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT fuming derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT zhangshuai derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT liangming derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT wangzulu derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance
AT hanyaling derivationandverificationoftherelationshipbetweenablationindexandbaselineimpedance