Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro

PURPOSE: The aim of the present study was to examine the retention force of monolithic zirconia copings cemented with various temporary cements on implant abutments in vitro. METHODS: Sixty exercise implants with pre-screwed implant abutments were embedded in resin. Subsequently, 60 CAD/CAM manufact...

Descripción completa

Detalles Bibliográficos
Autores principales: Dähne, Felix, Meißner, Heike, Böning, Klaus, Arnold, Christin, Gutwald, Ralf, Prause, Elisabeth
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8289925/
https://www.ncbi.nlm.nih.gov/pubmed/34282495
http://dx.doi.org/10.1186/s40729-021-00349-4
_version_ 1783724394883842048
author Dähne, Felix
Meißner, Heike
Böning, Klaus
Arnold, Christin
Gutwald, Ralf
Prause, Elisabeth
author_facet Dähne, Felix
Meißner, Heike
Böning, Klaus
Arnold, Christin
Gutwald, Ralf
Prause, Elisabeth
author_sort Dähne, Felix
collection PubMed
description PURPOSE: The aim of the present study was to examine the retention force of monolithic zirconia copings cemented with various temporary cements on implant abutments in vitro. METHODS: Sixty exercise implants with pre-screwed implant abutments were embedded in resin. Subsequently, 60 CAD/CAM manufactured zirconia copings were divided into three main groups [Harvard Implant Semi-permanent (HAV), implantlink semi Forte (IMP), Temp Bond NE (TBNE)]. The zirconia copings were cemented on the implant abutments and loaded with 35 N. Specimens were stored in distilled water (37 °C) for 24 h. Half of the test specimens of each group were subjected to a thermocycling (TC) process. Retention force was measured in a universal testing machine. Using magnifying glasses, the fracture mode was determined. Statistical analysis was performed applying the Kruskal-Wallis test, the post hoc test according to Dunn-Bonferroni and a chi-square test of independence. RESULTS: Without TC, IMP showed the highest retention of the three temporary luting agents (100.5 ± 39.14 N). The measured retention forces of IMP were higher than those of HAV (45.78 ± 15.66 N) and TBNE (61.16 ± 20.19 N). After TC, retention was reduced. IMP showed the greatest retentive strength (21.69 ± 13.61 N, three fail outs). HAV and TBNE showed pull-off forces of similar magnitude (17.38 ± 12.77 N and 16.97 ± 12.36 N, two fail outs). The fracture mode analysis showed different results regarding the tested cements before and after TC (facture type before/after TC): IMP (III+II/III), HAV (I/II) and TBNE (III/III). There were clear differences of the fracture modes regarding the examination before and after TC. CONCLUSIONS: Within the limits of this study, IMP showed the highest pull-off forces under the chosen test conditions. All three temporary luting agents showed lower retention forces after TC. Retention values in the individual cement classes were very heterogeneous. Easy cement removal in the crown lumen favours the dominance of adhesive cement fractures on the abutment and adhesive/cohesive cement fractures on the abutment with HAV appears advantageous in case of recementation of the superstructure.
format Online
Article
Text
id pubmed-8289925
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-82899252021-08-05 Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro Dähne, Felix Meißner, Heike Böning, Klaus Arnold, Christin Gutwald, Ralf Prause, Elisabeth Int J Implant Dent Research PURPOSE: The aim of the present study was to examine the retention force of monolithic zirconia copings cemented with various temporary cements on implant abutments in vitro. METHODS: Sixty exercise implants with pre-screwed implant abutments were embedded in resin. Subsequently, 60 CAD/CAM manufactured zirconia copings were divided into three main groups [Harvard Implant Semi-permanent (HAV), implantlink semi Forte (IMP), Temp Bond NE (TBNE)]. The zirconia copings were cemented on the implant abutments and loaded with 35 N. Specimens were stored in distilled water (37 °C) for 24 h. Half of the test specimens of each group were subjected to a thermocycling (TC) process. Retention force was measured in a universal testing machine. Using magnifying glasses, the fracture mode was determined. Statistical analysis was performed applying the Kruskal-Wallis test, the post hoc test according to Dunn-Bonferroni and a chi-square test of independence. RESULTS: Without TC, IMP showed the highest retention of the three temporary luting agents (100.5 ± 39.14 N). The measured retention forces of IMP were higher than those of HAV (45.78 ± 15.66 N) and TBNE (61.16 ± 20.19 N). After TC, retention was reduced. IMP showed the greatest retentive strength (21.69 ± 13.61 N, three fail outs). HAV and TBNE showed pull-off forces of similar magnitude (17.38 ± 12.77 N and 16.97 ± 12.36 N, two fail outs). The fracture mode analysis showed different results regarding the tested cements before and after TC (facture type before/after TC): IMP (III+II/III), HAV (I/II) and TBNE (III/III). There were clear differences of the fracture modes regarding the examination before and after TC. CONCLUSIONS: Within the limits of this study, IMP showed the highest pull-off forces under the chosen test conditions. All three temporary luting agents showed lower retention forces after TC. Retention values in the individual cement classes were very heterogeneous. Easy cement removal in the crown lumen favours the dominance of adhesive cement fractures on the abutment and adhesive/cohesive cement fractures on the abutment with HAV appears advantageous in case of recementation of the superstructure. Springer Berlin Heidelberg 2021-07-20 /pmc/articles/PMC8289925/ /pubmed/34282495 http://dx.doi.org/10.1186/s40729-021-00349-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Dähne, Felix
Meißner, Heike
Böning, Klaus
Arnold, Christin
Gutwald, Ralf
Prause, Elisabeth
Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
title Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
title_full Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
title_fullStr Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
title_full_unstemmed Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
title_short Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
title_sort retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8289925/
https://www.ncbi.nlm.nih.gov/pubmed/34282495
http://dx.doi.org/10.1186/s40729-021-00349-4
work_keys_str_mv AT dahnefelix retentionofdifferenttemporarycementstestedonzirconiacrownsandtitaniumabutmentsinvitro
AT meißnerheike retentionofdifferenttemporarycementstestedonzirconiacrownsandtitaniumabutmentsinvitro
AT boningklaus retentionofdifferenttemporarycementstestedonzirconiacrownsandtitaniumabutmentsinvitro
AT arnoldchristin retentionofdifferenttemporarycementstestedonzirconiacrownsandtitaniumabutmentsinvitro
AT gutwaldralf retentionofdifferenttemporarycementstestedonzirconiacrownsandtitaniumabutmentsinvitro
AT prauseelisabeth retentionofdifferenttemporarycementstestedonzirconiacrownsandtitaniumabutmentsinvitro