Cargando…

Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia

The work aimed to evaluate the effectiveness of the developed distraction system based on the rod external monolateral fixation mechanisms by comparing it with the classical technique of long tubular bones distraction based on the circular multi-axial system. The study included patients with a genet...

Descripción completa

Detalles Bibliográficos
Autores principales: Dossanov, Bolatbek, Trofimchuk, Vitaliy, Lozovoy, Vassiliy, Khmyzov, Sergey, Dossanova, Assem, Zhukenov, Olzhas, Tuktiyeva, Nazym, Angelov, Aleksandr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8290032/
https://www.ncbi.nlm.nih.gov/pubmed/34282216
http://dx.doi.org/10.1038/s41598-021-94146-z
_version_ 1783724408625430528
author Dossanov, Bolatbek
Trofimchuk, Vitaliy
Lozovoy, Vassiliy
Khmyzov, Sergey
Dossanova, Assem
Zhukenov, Olzhas
Tuktiyeva, Nazym
Angelov, Aleksandr
author_facet Dossanov, Bolatbek
Trofimchuk, Vitaliy
Lozovoy, Vassiliy
Khmyzov, Sergey
Dossanova, Assem
Zhukenov, Olzhas
Tuktiyeva, Nazym
Angelov, Aleksandr
author_sort Dossanov, Bolatbek
collection PubMed
description The work aimed to evaluate the effectiveness of the developed distraction system based on the rod external monolateral fixation mechanisms by comparing it with the classical technique of long tubular bones distraction based on the circular multi-axial system. The study included patients with a genetically confirmed diagnosis of achondroplasia. The experimental group consisted of 14 patients who underwent surgical limb lengthening by the rod monolateral external fixator with a distraction system developed by the authors. The lengthening was performed on 28 segments of tubular bones. The majority of the experimental group patients achieved the lengthening value close to the planned one and the deformation correction. The fixation period was averagely 83.8 ± 3.7 days, the regenerate length was 8.5 ± 0.6 cm, and the mechanical strength of the distraction regenerate was 10.3° ± 2.18°. The rod external fixator with a control distraction system developed by the authors has small dimensions and low weight of the external supporting elements of high durability. It is reported to provide a good psychological tolerance of the treatment process and significantly outperforms the circular multi-axis system. Considering the aforementioned, the proposed apparatus can grant good orthopedic care to patients with achondroplasia.
format Online
Article
Text
id pubmed-8290032
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-82900322021-07-21 Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia Dossanov, Bolatbek Trofimchuk, Vitaliy Lozovoy, Vassiliy Khmyzov, Sergey Dossanova, Assem Zhukenov, Olzhas Tuktiyeva, Nazym Angelov, Aleksandr Sci Rep Article The work aimed to evaluate the effectiveness of the developed distraction system based on the rod external monolateral fixation mechanisms by comparing it with the classical technique of long tubular bones distraction based on the circular multi-axial system. The study included patients with a genetically confirmed diagnosis of achondroplasia. The experimental group consisted of 14 patients who underwent surgical limb lengthening by the rod monolateral external fixator with a distraction system developed by the authors. The lengthening was performed on 28 segments of tubular bones. The majority of the experimental group patients achieved the lengthening value close to the planned one and the deformation correction. The fixation period was averagely 83.8 ± 3.7 days, the regenerate length was 8.5 ± 0.6 cm, and the mechanical strength of the distraction regenerate was 10.3° ± 2.18°. The rod external fixator with a control distraction system developed by the authors has small dimensions and low weight of the external supporting elements of high durability. It is reported to provide a good psychological tolerance of the treatment process and significantly outperforms the circular multi-axis system. Considering the aforementioned, the proposed apparatus can grant good orthopedic care to patients with achondroplasia. Nature Publishing Group UK 2021-07-19 /pmc/articles/PMC8290032/ /pubmed/34282216 http://dx.doi.org/10.1038/s41598-021-94146-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Dossanov, Bolatbek
Trofimchuk, Vitaliy
Lozovoy, Vassiliy
Khmyzov, Sergey
Dossanova, Assem
Zhukenov, Olzhas
Tuktiyeva, Nazym
Angelov, Aleksandr
Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia
title Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia
title_full Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia
title_fullStr Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia
title_full_unstemmed Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia
title_short Evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia
title_sort evaluating the results of long tubular bone distraction with an advanced rod monolateral external fixator for achondroplasia
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8290032/
https://www.ncbi.nlm.nih.gov/pubmed/34282216
http://dx.doi.org/10.1038/s41598-021-94146-z
work_keys_str_mv AT dossanovbolatbek evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia
AT trofimchukvitaliy evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia
AT lozovoyvassiliy evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia
AT khmyzovsergey evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia
AT dossanovaassem evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia
AT zhukenovolzhas evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia
AT tuktiyevanazym evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia
AT angelovaleksandr evaluatingtheresultsoflongtubularbonedistractionwithanadvancedrodmonolateralexternalfixatorforachondroplasia