Cargando…
Optimized procedures for testing plasma metanephrines in patients on hemodialysis
Diagnosis of pheochromocytomas and paragangliomas in patients receiving hemodialysis is troublesome. The aim of the study was to establish optimal conditions for blood sampling for mass spectrometric measurements of normetanephrine, metanephrine and 3-methoxytyramine in patients on hemodialysis and...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8290036/ https://www.ncbi.nlm.nih.gov/pubmed/34282182 http://dx.doi.org/10.1038/s41598-021-94104-9 |
_version_ | 1783724409552371712 |
---|---|
author | Pamporaki, Christina Prejbisz, Aleksander Małecki, Robert Pistrosch, Frank Peitzsch, Mirko Bishoff, Steffen Mueller, Petra Meyer, Iris Reimann, Doreen Hanus, Katarzyna Januszewicz, Andrzej Bornstein, Stefan R. Parmentier, Simon Kunath, Carola Lenders, Jacques W. M. Eisenhofer, Graeme Passauer, Jens |
author_facet | Pamporaki, Christina Prejbisz, Aleksander Małecki, Robert Pistrosch, Frank Peitzsch, Mirko Bishoff, Steffen Mueller, Petra Meyer, Iris Reimann, Doreen Hanus, Katarzyna Januszewicz, Andrzej Bornstein, Stefan R. Parmentier, Simon Kunath, Carola Lenders, Jacques W. M. Eisenhofer, Graeme Passauer, Jens |
author_sort | Pamporaki, Christina |
collection | PubMed |
description | Diagnosis of pheochromocytomas and paragangliomas in patients receiving hemodialysis is troublesome. The aim of the study was to establish optimal conditions for blood sampling for mass spectrometric measurements of normetanephrine, metanephrine and 3-methoxytyramine in patients on hemodialysis and specific reference intervals for plasma metanephrines under the most optimal sampling conditions. Blood was sampled before and near the end of dialysis, including different sampling sites in 170 patients on hemodialysis. Plasma normetanephrine concentrations were lower (P < 0.0001) and metanephrine concentrations higher (P < 0.0001) in shunt than in venous blood, with no differences for 3-methoxytyramine. Normetanephrine, metanephrine and 3-methoxytyramine concentrations in shunt and venous blood were lower (P < 0.0001) near the end than before hemodialysis. Upper cut-offs for normetanephrine were 34% lower when the blood was drawn from the shunt and near the end of hemodialysis compared to blood drawn before hemodialysis. This study establishes optimal sampling conditions using blood from the dialysis shunt near the end of hemodialysis with optimal reference intervals for plasma metanephrines for the diagnosis of pheochromocytomas/paragangliomas among patients on hemodialysis. |
format | Online Article Text |
id | pubmed-8290036 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-82900362021-07-21 Optimized procedures for testing plasma metanephrines in patients on hemodialysis Pamporaki, Christina Prejbisz, Aleksander Małecki, Robert Pistrosch, Frank Peitzsch, Mirko Bishoff, Steffen Mueller, Petra Meyer, Iris Reimann, Doreen Hanus, Katarzyna Januszewicz, Andrzej Bornstein, Stefan R. Parmentier, Simon Kunath, Carola Lenders, Jacques W. M. Eisenhofer, Graeme Passauer, Jens Sci Rep Article Diagnosis of pheochromocytomas and paragangliomas in patients receiving hemodialysis is troublesome. The aim of the study was to establish optimal conditions for blood sampling for mass spectrometric measurements of normetanephrine, metanephrine and 3-methoxytyramine in patients on hemodialysis and specific reference intervals for plasma metanephrines under the most optimal sampling conditions. Blood was sampled before and near the end of dialysis, including different sampling sites in 170 patients on hemodialysis. Plasma normetanephrine concentrations were lower (P < 0.0001) and metanephrine concentrations higher (P < 0.0001) in shunt than in venous blood, with no differences for 3-methoxytyramine. Normetanephrine, metanephrine and 3-methoxytyramine concentrations in shunt and venous blood were lower (P < 0.0001) near the end than before hemodialysis. Upper cut-offs for normetanephrine were 34% lower when the blood was drawn from the shunt and near the end of hemodialysis compared to blood drawn before hemodialysis. This study establishes optimal sampling conditions using blood from the dialysis shunt near the end of hemodialysis with optimal reference intervals for plasma metanephrines for the diagnosis of pheochromocytomas/paragangliomas among patients on hemodialysis. Nature Publishing Group UK 2021-07-19 /pmc/articles/PMC8290036/ /pubmed/34282182 http://dx.doi.org/10.1038/s41598-021-94104-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Pamporaki, Christina Prejbisz, Aleksander Małecki, Robert Pistrosch, Frank Peitzsch, Mirko Bishoff, Steffen Mueller, Petra Meyer, Iris Reimann, Doreen Hanus, Katarzyna Januszewicz, Andrzej Bornstein, Stefan R. Parmentier, Simon Kunath, Carola Lenders, Jacques W. M. Eisenhofer, Graeme Passauer, Jens Optimized procedures for testing plasma metanephrines in patients on hemodialysis |
title | Optimized procedures for testing plasma metanephrines in patients on hemodialysis |
title_full | Optimized procedures for testing plasma metanephrines in patients on hemodialysis |
title_fullStr | Optimized procedures for testing plasma metanephrines in patients on hemodialysis |
title_full_unstemmed | Optimized procedures for testing plasma metanephrines in patients on hemodialysis |
title_short | Optimized procedures for testing plasma metanephrines in patients on hemodialysis |
title_sort | optimized procedures for testing plasma metanephrines in patients on hemodialysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8290036/ https://www.ncbi.nlm.nih.gov/pubmed/34282182 http://dx.doi.org/10.1038/s41598-021-94104-9 |
work_keys_str_mv | AT pamporakichristina optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT prejbiszaleksander optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT małeckirobert optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT pistroschfrank optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT peitzschmirko optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT bishoffsteffen optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT muellerpetra optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT meyeriris optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT reimanndoreen optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT hanuskatarzyna optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT januszewiczandrzej optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT bornsteinstefanr optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT parmentiersimon optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT kunathcarola optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT lendersjacqueswm optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT eisenhofergraeme optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis AT passauerjens optimizedproceduresfortestingplasmametanephrinesinpatientsonhemodialysis |