Cargando…
Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances
Manufacturing of Fränkel's functional regulator 3 (FR3) is complicated and requires extensive knowledge from the dental technician. To determine whether FR3s produced by CAD/CAM techniques (CAD-FR3) meet similar mechanical properties like conventional FR3s (Con-FR3), for each of 10 patient case...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8290040/ https://www.ncbi.nlm.nih.gov/pubmed/34282228 http://dx.doi.org/10.1038/s41598-021-94237-x |
_version_ | 1783724410573684736 |
---|---|
author | Roser, Christoph Hodecker, Lutz D. Koebel, Chris Lux, Christopher J. Ruckes, Dorothee Rues, Stefan Zenthöfer, Andreas |
author_facet | Roser, Christoph Hodecker, Lutz D. Koebel, Chris Lux, Christopher J. Ruckes, Dorothee Rues, Stefan Zenthöfer, Andreas |
author_sort | Roser, Christoph |
collection | PubMed |
description | Manufacturing of Fränkel's functional regulator 3 (FR3) is complicated and requires extensive knowledge from the dental technician. To determine whether FR3s produced by CAD/CAM techniques (CAD-FR3) meet similar mechanical properties like conventional FR3s (Con-FR3), for each of 10 patient cases, three CAD-FR3 designs (palatal connector cross-section 3 × 3 mm, 4 × 1 mm or 5 × 2 mm) and one Con-FR3 were subjected to cyclic loading and subsequent fracture testing in a universal testing device. Transversal load capacity (F(max(FR3))) and stiffness were compared among the different CAD-FR3 designs and Con-FR3s using Friedman and Wilcoxon tests with a significance level of α = 0.05. All CAD-FR3 designs had significantly higher mean F(max(FR3)) (p ≤ 0.007) and stiffness (p ≤ 0.005) than the Con-FR3s. The CAD-FR3(3×3) had the highest mean F(max(FR3)) (98.2 ± 26.2 N) and stiffness (37.1 ± 15.5 N/mm), closely followed by the CAD-FR3(5×2) (F(max(FR3)): 90.3 ± 24.7 N; stiffness: 30.0 ± 12.3 N/mm). Among the CAD appliances, CAD-FR3(4×1) had the lowest values (p ≤ 0.007 for all pairwise tests) with F(max(FR3)) of 45.8 ± 17.9 N and stiffness of 12.5 ± 7.3 N/mm. CAD-FR3s have superior mechanical properties in comparison to Con-FR3s if certain design parameters are followed. Further clinical investigations have to examine if they can serve as an alternative in practice. |
format | Online Article Text |
id | pubmed-8290040 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-82900402021-07-21 Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances Roser, Christoph Hodecker, Lutz D. Koebel, Chris Lux, Christopher J. Ruckes, Dorothee Rues, Stefan Zenthöfer, Andreas Sci Rep Article Manufacturing of Fränkel's functional regulator 3 (FR3) is complicated and requires extensive knowledge from the dental technician. To determine whether FR3s produced by CAD/CAM techniques (CAD-FR3) meet similar mechanical properties like conventional FR3s (Con-FR3), for each of 10 patient cases, three CAD-FR3 designs (palatal connector cross-section 3 × 3 mm, 4 × 1 mm or 5 × 2 mm) and one Con-FR3 were subjected to cyclic loading and subsequent fracture testing in a universal testing device. Transversal load capacity (F(max(FR3))) and stiffness were compared among the different CAD-FR3 designs and Con-FR3s using Friedman and Wilcoxon tests with a significance level of α = 0.05. All CAD-FR3 designs had significantly higher mean F(max(FR3)) (p ≤ 0.007) and stiffness (p ≤ 0.005) than the Con-FR3s. The CAD-FR3(3×3) had the highest mean F(max(FR3)) (98.2 ± 26.2 N) and stiffness (37.1 ± 15.5 N/mm), closely followed by the CAD-FR3(5×2) (F(max(FR3)): 90.3 ± 24.7 N; stiffness: 30.0 ± 12.3 N/mm). Among the CAD appliances, CAD-FR3(4×1) had the lowest values (p ≤ 0.007 for all pairwise tests) with F(max(FR3)) of 45.8 ± 17.9 N and stiffness of 12.5 ± 7.3 N/mm. CAD-FR3s have superior mechanical properties in comparison to Con-FR3s if certain design parameters are followed. Further clinical investigations have to examine if they can serve as an alternative in practice. Nature Publishing Group UK 2021-07-19 /pmc/articles/PMC8290040/ /pubmed/34282228 http://dx.doi.org/10.1038/s41598-021-94237-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Roser, Christoph Hodecker, Lutz D. Koebel, Chris Lux, Christopher J. Ruckes, Dorothee Rues, Stefan Zenthöfer, Andreas Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
title | Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
title_full | Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
title_fullStr | Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
title_full_unstemmed | Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
title_short | Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
title_sort | mechanical properties of cad/cam-fabricated in comparison to conventionally fabricated functional regulator 3 appliances |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8290040/ https://www.ncbi.nlm.nih.gov/pubmed/34282228 http://dx.doi.org/10.1038/s41598-021-94237-x |
work_keys_str_mv | AT roserchristoph mechanicalpropertiesofcadcamfabricatedincomparisontoconventionallyfabricatedfunctionalregulator3appliances AT hodeckerlutzd mechanicalpropertiesofcadcamfabricatedincomparisontoconventionallyfabricatedfunctionalregulator3appliances AT koebelchris mechanicalpropertiesofcadcamfabricatedincomparisontoconventionallyfabricatedfunctionalregulator3appliances AT luxchristopherj mechanicalpropertiesofcadcamfabricatedincomparisontoconventionallyfabricatedfunctionalregulator3appliances AT ruckesdorothee mechanicalpropertiesofcadcamfabricatedincomparisontoconventionallyfabricatedfunctionalregulator3appliances AT ruesstefan mechanicalpropertiesofcadcamfabricatedincomparisontoconventionallyfabricatedfunctionalregulator3appliances AT zenthoferandreas mechanicalpropertiesofcadcamfabricatedincomparisontoconventionallyfabricatedfunctionalregulator3appliances |