Cargando…

Torrents of torment: turbulence as a mechanism of pulsatile tinnitus secondary to venous stenosis revealed by high-fidelity computational fluid dynamics

BACKGROUND: Pulsatile tinnitus (PT) is a debilitating condition that can be caused by a vascular abnormality, such as an arterial or venous lesion. Although treatment of PT-related venous lesions has been shown to successfully cure patients of the associated ‘tormenting’ rhythmical sound, much contr...

Descripción completa

Detalles Bibliográficos
Autores principales: Pereira, Vitor M, Cancelliere, Nicole Mariantonia, Najafi, Mehdi, MacDonald, Dan, Natarajan, Thangam, Radovanovic, Ivan, Krings, Timo, Rutka, John, Nicholson, Patrick, Steinman, David A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8292577/
https://www.ncbi.nlm.nih.gov/pubmed/33219149
http://dx.doi.org/10.1136/neurintsurg-2020-016636
Descripción
Sumario:BACKGROUND: Pulsatile tinnitus (PT) is a debilitating condition that can be caused by a vascular abnormality, such as an arterial or venous lesion. Although treatment of PT-related venous lesions has been shown to successfully cure patients of the associated ‘tormenting’ rhythmical sound, much controversy still exists regarding their role in the etiology of PT. METHODS: A patient presented with a history of worsening, unilateral PT. A partial venous sinus obstruction related to the large arachnoid granulation was detected on the right side, and subsequently stented at the right transverse sinus. High-fidelity computational fluid dynamics (CFD) was performed on a 3D model digitally segmented from the pre-stent venogram, with assumed pulsatile flow rates. A post-stent CFD model was also constructed from this. Data-driven sonification was performed on the CFD velocity data, blinded to the patient’s self-reported sounds. RESULTS: The patient reported that the PT was completely resolved after stenting, and has had no recurrence of the symptoms after more than 2 years. CFD simulation revealed highly disturbed, turbulent-like flow at the sigmoid sinus close to auditory structures, producing a sonified audio signal that reproduced the subjective sonance of the patient’s PT. No turbulence or sounds were evident at the stenosis, or anywhere in the post-stent model. CONCLUSIONS: For the first time, turbulence generated distal to a venous stenosis is shown to be a cause of PT. High-fidelity CFD may be useful for identifying patients with such ‘torrents’ of flow, to help guide treatment decision-making.