Cargando…
Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation
PURPOSE: Although the imaging of luminescence emitted in water during irradiation of protons and carbon ions is a useful method for range and dose estimations, the intensity of the images is relatively low due to the low photon production of the luminescence phenomenon. Therefore, a relatively long...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8292686/ https://www.ncbi.nlm.nih.gov/pubmed/34124832 http://dx.doi.org/10.1002/acm2.13309 |
_version_ | 1783724874179543040 |
---|---|
author | Yamamoto, Seiichi Yabe, Takuya Akagi, Takashi |
author_facet | Yamamoto, Seiichi Yabe, Takuya Akagi, Takashi |
author_sort | Yamamoto, Seiichi |
collection | PubMed |
description | PURPOSE: Although the imaging of luminescence emitted in water during irradiation of protons and carbon ions is a useful method for range and dose estimations, the intensity of the images is relatively low due to the low photon production of the luminescence phenomenon. Therefore, a relatively long time is required for the imaging. Since a fluorescent dye, fluorescein, may increase the intensity of the optical signal, we measured the luminescence images of water with different concentrations of fluorescein during irradiation of protons and carbon ions and compared the results with those by measurements with water. METHODS: A cooled charge‐coupled device (CCD) camera was used for imaging a water phantom with different concentrations of fluorescein from 0.0063 to 0.025 mg/cm(3), in addition to a water phantom without fluorescein during irradiation of 150‐MeV protons and 241.5‐MeV/n carbon ions. RESULTS: For both protons and carbon ions, the intensity of the luminescence images increased as the concentration of fluorescein increased. With a fluorescein concentration of 0.025 mg/cm(3), the intensities increased to more than 10 times those of water for both protons and carbon ions. Although the shape of the depth profiles of luminescence images of water with fluorescein appeared similar to that of water for protons, those for carbon ions were different from those of water due to the increase in the Cherenkov light component at shallow depths by the decrease in the angular dependencies of the Cherenkov light. CONCLUSION: We confirmed the increase in intensity of the luminescence of water by adding fluorescein for particle ions. With a small amount of Cherenkov light contamination in the images, such as protons, the relative distributions of the luminescence images with fluorescein were similar to that of water and will be used for range or dose determination in a short time. |
format | Online Article Text |
id | pubmed-8292686 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-82926862021-07-22 Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation Yamamoto, Seiichi Yabe, Takuya Akagi, Takashi J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Although the imaging of luminescence emitted in water during irradiation of protons and carbon ions is a useful method for range and dose estimations, the intensity of the images is relatively low due to the low photon production of the luminescence phenomenon. Therefore, a relatively long time is required for the imaging. Since a fluorescent dye, fluorescein, may increase the intensity of the optical signal, we measured the luminescence images of water with different concentrations of fluorescein during irradiation of protons and carbon ions and compared the results with those by measurements with water. METHODS: A cooled charge‐coupled device (CCD) camera was used for imaging a water phantom with different concentrations of fluorescein from 0.0063 to 0.025 mg/cm(3), in addition to a water phantom without fluorescein during irradiation of 150‐MeV protons and 241.5‐MeV/n carbon ions. RESULTS: For both protons and carbon ions, the intensity of the luminescence images increased as the concentration of fluorescein increased. With a fluorescein concentration of 0.025 mg/cm(3), the intensities increased to more than 10 times those of water for both protons and carbon ions. Although the shape of the depth profiles of luminescence images of water with fluorescein appeared similar to that of water for protons, those for carbon ions were different from those of water due to the increase in the Cherenkov light component at shallow depths by the decrease in the angular dependencies of the Cherenkov light. CONCLUSION: We confirmed the increase in intensity of the luminescence of water by adding fluorescein for particle ions. With a small amount of Cherenkov light contamination in the images, such as protons, the relative distributions of the luminescence images with fluorescein were similar to that of water and will be used for range or dose determination in a short time. John Wiley and Sons Inc. 2021-06-14 /pmc/articles/PMC8292686/ /pubmed/34124832 http://dx.doi.org/10.1002/acm2.13309 Text en © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Yamamoto, Seiichi Yabe, Takuya Akagi, Takashi Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation |
title | Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation |
title_full | Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation |
title_fullStr | Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation |
title_full_unstemmed | Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation |
title_short | Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation |
title_sort | increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8292686/ https://www.ncbi.nlm.nih.gov/pubmed/34124832 http://dx.doi.org/10.1002/acm2.13309 |
work_keys_str_mv | AT yamamotoseiichi increaseintheintensityofanopticalsignalwithfluoresceinduringprotonandcarbonionirradiation AT yabetakuya increaseintheintensityofanopticalsignalwithfluoresceinduringprotonandcarbonionirradiation AT akagitakashi increaseintheintensityofanopticalsignalwithfluoresceinduringprotonandcarbonionirradiation |