Cargando…
Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction
PURPOSE: To assess the ability of the Pentacam in predicting the corneal power after hyperopic small-incision lenticule extraction (SMILE). METHODS: Twenty-five eyes of 22 patients underwent hyperopic SMILE were prospectively followed. All patients finished at least 6 months visit. Cornea power was...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8293571/ https://www.ncbi.nlm.nih.gov/pubmed/34284749 http://dx.doi.org/10.1186/s12886-021-02043-w |
_version_ | 1783725069406568448 |
---|---|
author | Fu, Dan Shang, Jianmin Zhang, Xiaoyu Niu, Lingling Han, Tian Zhou, Xingtao |
author_facet | Fu, Dan Shang, Jianmin Zhang, Xiaoyu Niu, Lingling Han, Tian Zhou, Xingtao |
author_sort | Fu, Dan |
collection | PubMed |
description | PURPOSE: To assess the ability of the Pentacam in predicting the corneal power after hyperopic small-incision lenticule extraction (SMILE). METHODS: Twenty-five eyes of 22 patients underwent hyperopic SMILE were prospectively followed. All patients finished at least 6 months visit. Cornea power was obtained by Pentacam HR, in the format of mean keratometry (Km), equivalent keratometry (EKR) and total cornea refractive power (TCRP). Calculation of TCRP were centered on either the corneal apex or the pupil center within a ring or zone, giving a total of four different subtypes naming AR、AZ、PR、PZ. Clinical history method (CHM) was regarded as a gold standard and was compared with other cornea power parameters. RESULTS: Center difference had no impact on the TCRP values (PR vs AR and PZ vs AZ, P > 0.05). Compared with CHM, no difference was found in Km, EKR 4.0 mm, EKR 4.5 mm, PR 3.0 mm, PR 4.0 mm, AR 3.0 mm and AR 4.0 mm. PR 4.0 mm showed the least difference with CHM (− 0.14 ± 1.03D, P > 0.05). The 95% limit of agreement (LOA) of the TCRPs and CHM was not close. The top two were PR 3.0 mm and PR 4.0 mm, LOA of which were − 2.20 to 1.84 D and − 2.18 to 1.68 D respectively. Central cornea thickness was correlated with error (TCRP – CHM) of PR 4.0 mm (r = 0.58, P = 0.003). CONCLUSIONS: The Pentacam topographer is an alternative method of measuring corneal power in eyes after hyperopic SMILE. The optimal options seem to be the TCRP (PR 4.0 mm). The agreement needs more verifications. |
format | Online Article Text |
id | pubmed-8293571 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-82935712021-07-21 Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction Fu, Dan Shang, Jianmin Zhang, Xiaoyu Niu, Lingling Han, Tian Zhou, Xingtao BMC Ophthalmol Research PURPOSE: To assess the ability of the Pentacam in predicting the corneal power after hyperopic small-incision lenticule extraction (SMILE). METHODS: Twenty-five eyes of 22 patients underwent hyperopic SMILE were prospectively followed. All patients finished at least 6 months visit. Cornea power was obtained by Pentacam HR, in the format of mean keratometry (Km), equivalent keratometry (EKR) and total cornea refractive power (TCRP). Calculation of TCRP were centered on either the corneal apex or the pupil center within a ring or zone, giving a total of four different subtypes naming AR、AZ、PR、PZ. Clinical history method (CHM) was regarded as a gold standard and was compared with other cornea power parameters. RESULTS: Center difference had no impact on the TCRP values (PR vs AR and PZ vs AZ, P > 0.05). Compared with CHM, no difference was found in Km, EKR 4.0 mm, EKR 4.5 mm, PR 3.0 mm, PR 4.0 mm, AR 3.0 mm and AR 4.0 mm. PR 4.0 mm showed the least difference with CHM (− 0.14 ± 1.03D, P > 0.05). The 95% limit of agreement (LOA) of the TCRPs and CHM was not close. The top two were PR 3.0 mm and PR 4.0 mm, LOA of which were − 2.20 to 1.84 D and − 2.18 to 1.68 D respectively. Central cornea thickness was correlated with error (TCRP – CHM) of PR 4.0 mm (r = 0.58, P = 0.003). CONCLUSIONS: The Pentacam topographer is an alternative method of measuring corneal power in eyes after hyperopic SMILE. The optimal options seem to be the TCRP (PR 4.0 mm). The agreement needs more verifications. BioMed Central 2021-07-20 /pmc/articles/PMC8293571/ /pubmed/34284749 http://dx.doi.org/10.1186/s12886-021-02043-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Fu, Dan Shang, Jianmin Zhang, Xiaoyu Niu, Lingling Han, Tian Zhou, Xingtao Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction |
title | Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction |
title_full | Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction |
title_fullStr | Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction |
title_full_unstemmed | Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction |
title_short | Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction |
title_sort | scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8293571/ https://www.ncbi.nlm.nih.gov/pubmed/34284749 http://dx.doi.org/10.1186/s12886-021-02043-w |
work_keys_str_mv | AT fudan scheimpfluganalysisofcornealpowerchangesafterhyperopicsmallincisionlenticuleextraction AT shangjianmin scheimpfluganalysisofcornealpowerchangesafterhyperopicsmallincisionlenticuleextraction AT zhangxiaoyu scheimpfluganalysisofcornealpowerchangesafterhyperopicsmallincisionlenticuleextraction AT niulingling scheimpfluganalysisofcornealpowerchangesafterhyperopicsmallincisionlenticuleextraction AT hantian scheimpfluganalysisofcornealpowerchangesafterhyperopicsmallincisionlenticuleextraction AT zhouxingtao scheimpfluganalysisofcornealpowerchangesafterhyperopicsmallincisionlenticuleextraction |