Cargando…
Kinematic gait characteristics of straight line walk in clinically sound dairy cows
The aim of this study is to describe the kinematic gait characteristics of straight line walk in clinically sound dairy cows using body mounted Inertial Measurement Units (IMUs) at multiple anatomical locations. The temporal parameters used are speed and non-speed normalized stance duration, bipedal...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8294546/ https://www.ncbi.nlm.nih.gov/pubmed/34288912 http://dx.doi.org/10.1371/journal.pone.0253479 |
_version_ | 1783725257987719168 |
---|---|
author | Tijssen, M. Serra Braganςa, F. M. Ask, K. Rhodin, M. Andersen, P. H. Telezhenko, E. Bergsten, C. Nielen, M. Hernlund, E. |
author_facet | Tijssen, M. Serra Braganςa, F. M. Ask, K. Rhodin, M. Andersen, P. H. Telezhenko, E. Bergsten, C. Nielen, M. Hernlund, E. |
author_sort | Tijssen, M. |
collection | PubMed |
description | The aim of this study is to describe the kinematic gait characteristics of straight line walk in clinically sound dairy cows using body mounted Inertial Measurement Units (IMUs) at multiple anatomical locations. The temporal parameters used are speed and non-speed normalized stance duration, bipedal and tripedal support durations, maximal protraction and retraction angles of the distal limbs and vertical displacement curves of the upper body. Gait analysis was performed by letting 17 dairy cows walk in a straight line at their own chosen pace while equipped with IMU sensors on tubera sacrale, left and right tuber coxae (LTC and RTC), back, withers, head, neck and all four lower limbs. Data intervals with stride by stride regularity were selected based on video data. For temporal parameters, the median was calculated and 95% confidence intervals (CI) were estimated based on linear mixed model (LMM) analysis, while for limb and vertical displacement curves, the median and most typical curves were calculated. The temporal parameters and distal limb angles showed consistent results with low variance and LMM analysis showed non-overlapping CI for all temporal parameters. The distal limb angle curves showed a larger and steeper retraction angle range for the distal front limbs compared with the hind limbs. The vertical displacement curves of the sacrum, withers, LTC and RTC showed a consistent sinusoidal pattern while the head, back and collar curves were less consistent and showed more variation between and within cows. This kinematic description might allow to objectively differentiate between normal and lame gait in the future and determine the best anatomical location for sensor attachment for lameness detection purposes. |
format | Online Article Text |
id | pubmed-8294546 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-82945462021-07-31 Kinematic gait characteristics of straight line walk in clinically sound dairy cows Tijssen, M. Serra Braganςa, F. M. Ask, K. Rhodin, M. Andersen, P. H. Telezhenko, E. Bergsten, C. Nielen, M. Hernlund, E. PLoS One Research Article The aim of this study is to describe the kinematic gait characteristics of straight line walk in clinically sound dairy cows using body mounted Inertial Measurement Units (IMUs) at multiple anatomical locations. The temporal parameters used are speed and non-speed normalized stance duration, bipedal and tripedal support durations, maximal protraction and retraction angles of the distal limbs and vertical displacement curves of the upper body. Gait analysis was performed by letting 17 dairy cows walk in a straight line at their own chosen pace while equipped with IMU sensors on tubera sacrale, left and right tuber coxae (LTC and RTC), back, withers, head, neck and all four lower limbs. Data intervals with stride by stride regularity were selected based on video data. For temporal parameters, the median was calculated and 95% confidence intervals (CI) were estimated based on linear mixed model (LMM) analysis, while for limb and vertical displacement curves, the median and most typical curves were calculated. The temporal parameters and distal limb angles showed consistent results with low variance and LMM analysis showed non-overlapping CI for all temporal parameters. The distal limb angle curves showed a larger and steeper retraction angle range for the distal front limbs compared with the hind limbs. The vertical displacement curves of the sacrum, withers, LTC and RTC showed a consistent sinusoidal pattern while the head, back and collar curves were less consistent and showed more variation between and within cows. This kinematic description might allow to objectively differentiate between normal and lame gait in the future and determine the best anatomical location for sensor attachment for lameness detection purposes. Public Library of Science 2021-07-21 /pmc/articles/PMC8294546/ /pubmed/34288912 http://dx.doi.org/10.1371/journal.pone.0253479 Text en © 2021 Tijssen et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Tijssen, M. Serra Braganςa, F. M. Ask, K. Rhodin, M. Andersen, P. H. Telezhenko, E. Bergsten, C. Nielen, M. Hernlund, E. Kinematic gait characteristics of straight line walk in clinically sound dairy cows |
title | Kinematic gait characteristics of straight line walk in clinically sound dairy cows |
title_full | Kinematic gait characteristics of straight line walk in clinically sound dairy cows |
title_fullStr | Kinematic gait characteristics of straight line walk in clinically sound dairy cows |
title_full_unstemmed | Kinematic gait characteristics of straight line walk in clinically sound dairy cows |
title_short | Kinematic gait characteristics of straight line walk in clinically sound dairy cows |
title_sort | kinematic gait characteristics of straight line walk in clinically sound dairy cows |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8294546/ https://www.ncbi.nlm.nih.gov/pubmed/34288912 http://dx.doi.org/10.1371/journal.pone.0253479 |
work_keys_str_mv | AT tijssenm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT serrabragansafm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT askk kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT rhodinm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT andersenph kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT telezhenkoe kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT bergstenc kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT nielenm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows AT hernlunde kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows |