Cargando…

Kinematic gait characteristics of straight line walk in clinically sound dairy cows

The aim of this study is to describe the kinematic gait characteristics of straight line walk in clinically sound dairy cows using body mounted Inertial Measurement Units (IMUs) at multiple anatomical locations. The temporal parameters used are speed and non-speed normalized stance duration, bipedal...

Descripción completa

Detalles Bibliográficos
Autores principales: Tijssen, M., Serra Braganςa, F. M., Ask, K., Rhodin, M., Andersen, P. H., Telezhenko, E., Bergsten, C., Nielen, M., Hernlund, E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8294546/
https://www.ncbi.nlm.nih.gov/pubmed/34288912
http://dx.doi.org/10.1371/journal.pone.0253479
_version_ 1783725257987719168
author Tijssen, M.
Serra Braganςa, F. M.
Ask, K.
Rhodin, M.
Andersen, P. H.
Telezhenko, E.
Bergsten, C.
Nielen, M.
Hernlund, E.
author_facet Tijssen, M.
Serra Braganςa, F. M.
Ask, K.
Rhodin, M.
Andersen, P. H.
Telezhenko, E.
Bergsten, C.
Nielen, M.
Hernlund, E.
author_sort Tijssen, M.
collection PubMed
description The aim of this study is to describe the kinematic gait characteristics of straight line walk in clinically sound dairy cows using body mounted Inertial Measurement Units (IMUs) at multiple anatomical locations. The temporal parameters used are speed and non-speed normalized stance duration, bipedal and tripedal support durations, maximal protraction and retraction angles of the distal limbs and vertical displacement curves of the upper body. Gait analysis was performed by letting 17 dairy cows walk in a straight line at their own chosen pace while equipped with IMU sensors on tubera sacrale, left and right tuber coxae (LTC and RTC), back, withers, head, neck and all four lower limbs. Data intervals with stride by stride regularity were selected based on video data. For temporal parameters, the median was calculated and 95% confidence intervals (CI) were estimated based on linear mixed model (LMM) analysis, while for limb and vertical displacement curves, the median and most typical curves were calculated. The temporal parameters and distal limb angles showed consistent results with low variance and LMM analysis showed non-overlapping CI for all temporal parameters. The distal limb angle curves showed a larger and steeper retraction angle range for the distal front limbs compared with the hind limbs. The vertical displacement curves of the sacrum, withers, LTC and RTC showed a consistent sinusoidal pattern while the head, back and collar curves were less consistent and showed more variation between and within cows. This kinematic description might allow to objectively differentiate between normal and lame gait in the future and determine the best anatomical location for sensor attachment for lameness detection purposes.
format Online
Article
Text
id pubmed-8294546
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-82945462021-07-31 Kinematic gait characteristics of straight line walk in clinically sound dairy cows Tijssen, M. Serra Braganςa, F. M. Ask, K. Rhodin, M. Andersen, P. H. Telezhenko, E. Bergsten, C. Nielen, M. Hernlund, E. PLoS One Research Article The aim of this study is to describe the kinematic gait characteristics of straight line walk in clinically sound dairy cows using body mounted Inertial Measurement Units (IMUs) at multiple anatomical locations. The temporal parameters used are speed and non-speed normalized stance duration, bipedal and tripedal support durations, maximal protraction and retraction angles of the distal limbs and vertical displacement curves of the upper body. Gait analysis was performed by letting 17 dairy cows walk in a straight line at their own chosen pace while equipped with IMU sensors on tubera sacrale, left and right tuber coxae (LTC and RTC), back, withers, head, neck and all four lower limbs. Data intervals with stride by stride regularity were selected based on video data. For temporal parameters, the median was calculated and 95% confidence intervals (CI) were estimated based on linear mixed model (LMM) analysis, while for limb and vertical displacement curves, the median and most typical curves were calculated. The temporal parameters and distal limb angles showed consistent results with low variance and LMM analysis showed non-overlapping CI for all temporal parameters. The distal limb angle curves showed a larger and steeper retraction angle range for the distal front limbs compared with the hind limbs. The vertical displacement curves of the sacrum, withers, LTC and RTC showed a consistent sinusoidal pattern while the head, back and collar curves were less consistent and showed more variation between and within cows. This kinematic description might allow to objectively differentiate between normal and lame gait in the future and determine the best anatomical location for sensor attachment for lameness detection purposes. Public Library of Science 2021-07-21 /pmc/articles/PMC8294546/ /pubmed/34288912 http://dx.doi.org/10.1371/journal.pone.0253479 Text en © 2021 Tijssen et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tijssen, M.
Serra Braganςa, F. M.
Ask, K.
Rhodin, M.
Andersen, P. H.
Telezhenko, E.
Bergsten, C.
Nielen, M.
Hernlund, E.
Kinematic gait characteristics of straight line walk in clinically sound dairy cows
title Kinematic gait characteristics of straight line walk in clinically sound dairy cows
title_full Kinematic gait characteristics of straight line walk in clinically sound dairy cows
title_fullStr Kinematic gait characteristics of straight line walk in clinically sound dairy cows
title_full_unstemmed Kinematic gait characteristics of straight line walk in clinically sound dairy cows
title_short Kinematic gait characteristics of straight line walk in clinically sound dairy cows
title_sort kinematic gait characteristics of straight line walk in clinically sound dairy cows
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8294546/
https://www.ncbi.nlm.nih.gov/pubmed/34288912
http://dx.doi.org/10.1371/journal.pone.0253479
work_keys_str_mv AT tijssenm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT serrabragansafm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT askk kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT rhodinm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT andersenph kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT telezhenkoe kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT bergstenc kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT nielenm kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows
AT hernlunde kinematicgaitcharacteristicsofstraightlinewalkinclinicallysounddairycows