Cargando…

Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial

BACKGROUND: Endotracheal tube (ETT) with a tapered-shaped cuff had an improved sealing effect when compared to ETTs with a conventional cylindrical-shaped cuff. Positional change and neck movement typically displace an ETT and change the intracuff pressure. The aim of the current study was to compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Ji-Hoon, Lee, Hyo-Jin, Lee, Sou Hyun, Kim, Ji Seob
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8294867/
https://www.ncbi.nlm.nih.gov/pubmed/34398020
http://dx.doi.org/10.1097/MD.0000000000026633
_version_ 1783725317688393728
author Park, Ji-Hoon
Lee, Hyo-Jin
Lee, Sou Hyun
Kim, Ji Seob
author_facet Park, Ji-Hoon
Lee, Hyo-Jin
Lee, Sou Hyun
Kim, Ji Seob
author_sort Park, Ji-Hoon
collection PubMed
description BACKGROUND: Endotracheal tube (ETT) with a tapered-shaped cuff had an improved sealing effect when compared to ETTs with a conventional cylindrical-shaped cuff. Positional change and neck movement typically displace an ETT and change the intracuff pressure. The aim of the current study was to compare the ETT cuff pressure in the TaperGuard ETT vs the conventional ETT after a change from the supine, neutral position to the extension of the neck and semi-Fowler position for thyroid surgery. METHODS: This prospective, randomized clinical trial included 50 patients undergoing thyroidectomy. Patients were randomly allocated into one of the 2 groups: tracheal intubation with the TaperGuard ETT or with a conventional ETT. The ETT cuff was inflated with air and the ETT cuff pressure was set initially at 20 cmH(2)O using a calibrated cuff manometer. ETT cuff pressure and distance from carina to ETT tip were measured at supine and semi-Fowler positions with neck extension. RESULTS: After the position change, the ETT tip migrated cephalad and cuff pressure increased in the majority of cases. ETT cuff pressure was significantly higher in the TaperGuard group than the conventional group (28.0 ± 6.6 cmH(2)O and 22.8 ± 4.5 cmH(2)O, respectively, P = .001). The degree of cephalad displacement of the ETT tip was comparable between the 2 groups (19.4 ± 6.31 mm in TaperGuard group and 21.9 ± 6.9 mm in conventional group, P = .12). CONCLUSIONS: After the position change from supine to hyperextension of the neck, the ETT cuff pressure was higher in the TaperGuard ETT than in the conventional ETT, although the extent of displacement of the ETT was comparable between the 2 groups.
format Online
Article
Text
id pubmed-8294867
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-82948672021-07-24 Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial Park, Ji-Hoon Lee, Hyo-Jin Lee, Sou Hyun Kim, Ji Seob Medicine (Baltimore) 3300 BACKGROUND: Endotracheal tube (ETT) with a tapered-shaped cuff had an improved sealing effect when compared to ETTs with a conventional cylindrical-shaped cuff. Positional change and neck movement typically displace an ETT and change the intracuff pressure. The aim of the current study was to compare the ETT cuff pressure in the TaperGuard ETT vs the conventional ETT after a change from the supine, neutral position to the extension of the neck and semi-Fowler position for thyroid surgery. METHODS: This prospective, randomized clinical trial included 50 patients undergoing thyroidectomy. Patients were randomly allocated into one of the 2 groups: tracheal intubation with the TaperGuard ETT or with a conventional ETT. The ETT cuff was inflated with air and the ETT cuff pressure was set initially at 20 cmH(2)O using a calibrated cuff manometer. ETT cuff pressure and distance from carina to ETT tip were measured at supine and semi-Fowler positions with neck extension. RESULTS: After the position change, the ETT tip migrated cephalad and cuff pressure increased in the majority of cases. ETT cuff pressure was significantly higher in the TaperGuard group than the conventional group (28.0 ± 6.6 cmH(2)O and 22.8 ± 4.5 cmH(2)O, respectively, P = .001). The degree of cephalad displacement of the ETT tip was comparable between the 2 groups (19.4 ± 6.31 mm in TaperGuard group and 21.9 ± 6.9 mm in conventional group, P = .12). CONCLUSIONS: After the position change from supine to hyperextension of the neck, the ETT cuff pressure was higher in the TaperGuard ETT than in the conventional ETT, although the extent of displacement of the ETT was comparable between the 2 groups. Lippincott Williams & Wilkins 2021-07-23 /pmc/articles/PMC8294867/ /pubmed/34398020 http://dx.doi.org/10.1097/MD.0000000000026633 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle 3300
Park, Ji-Hoon
Lee, Hyo-Jin
Lee, Sou Hyun
Kim, Ji Seob
Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial
title Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial
title_full Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial
title_fullStr Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial
title_full_unstemmed Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial
title_short Changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: A randomized clinical trial
title_sort changes in tapered endotracheal tube cuff pressure after changing position to hyperextension of neck: a randomized clinical trial
topic 3300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8294867/
https://www.ncbi.nlm.nih.gov/pubmed/34398020
http://dx.doi.org/10.1097/MD.0000000000026633
work_keys_str_mv AT parkjihoon changesintaperedendotrachealtubecuffpressureafterchangingpositiontohyperextensionofneckarandomizedclinicaltrial
AT leehyojin changesintaperedendotrachealtubecuffpressureafterchangingpositiontohyperextensionofneckarandomizedclinicaltrial
AT leesouhyun changesintaperedendotrachealtubecuffpressureafterchangingpositiontohyperextensionofneckarandomizedclinicaltrial
AT kimjiseob changesintaperedendotrachealtubecuffpressureafterchangingpositiontohyperextensionofneckarandomizedclinicaltrial