Cargando…
Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series
BACKGROUND: Intra-articular fractures are associated with posttraumatic arthritis if inappropriately treated. Exact reduction of the joint congruency is the main factor to avoid the development of arthrosis. Aim of this study was to evaluate feasibility of computer-assisted surgical planning and 3D-...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8295140/ https://www.ncbi.nlm.nih.gov/pubmed/33715063 http://dx.doi.org/10.1007/s00402-021-03856-6 |
_version_ | 1783725380353392640 |
---|---|
author | Casari, F. A. Roner, S. Fürnstahl, P. Nagy, L. Schweizer, A. |
author_facet | Casari, F. A. Roner, S. Fürnstahl, P. Nagy, L. Schweizer, A. |
author_sort | Casari, F. A. |
collection | PubMed |
description | BACKGROUND: Intra-articular fractures are associated with posttraumatic arthritis if inappropriately treated. Exact reduction of the joint congruency is the main factor to avoid the development of arthrosis. Aim of this study was to evaluate feasibility of computer-assisted surgical planning and 3D-printed patient-specific instrumentation (PSI) for treatment of distal intraarticular radius fractures. METHOD: 7 Patients who suffered a distal intraarticular radius fracture were enrolled in this prospective case series. Preoperative CT-scan was recorded, whereupon a 3D model was computed for surgical planning and design of PSI for surgical navigation. Postoperative accuracy and joint congruency were assessed. Patients were followed-up 3, 6 and 12 months postoperatively. RESULTS: Mean follow-up was 16 months. Over all range of motion was restored and flexion, extension and pronation showed significant recovery, p < 0.05. Biggest intraarticular joint step-off and gap reduced from average 2.49 (± 1.04) to 0.8 mm (± 0.44), p < 0.05 and 6.12 mm (± 1.04) to 2.21 mm (± 1.16), p < 0.05. Average grip strength restored (3–16 months) from 20.33 kg (± 7.12) to 39.3 kg (± 19.55) p < 0.05, 100% of the healthy contralateral side. 3D-accuracy for guided fragments was 2.07 mm (± 0.64) and 8.59° (± 2.9) and 2.33 mm (± 0.69) and 12.86° (± 7.13), p > 0.05 for fragments reduced with ligamentotaxis. CONCLUSION: Computer-assisted and PSI navigated intraarticular radius fracture treatment is feasible, safe and accurate. The benefits of this method, however, do not outstand the additional effort. LEVEL OF EVIDENCE: IV. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00402-021-03856-6. |
format | Online Article Text |
id | pubmed-8295140 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-82951402021-07-23 Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series Casari, F. A. Roner, S. Fürnstahl, P. Nagy, L. Schweizer, A. Arch Orthop Trauma Surg Handsurgery BACKGROUND: Intra-articular fractures are associated with posttraumatic arthritis if inappropriately treated. Exact reduction of the joint congruency is the main factor to avoid the development of arthrosis. Aim of this study was to evaluate feasibility of computer-assisted surgical planning and 3D-printed patient-specific instrumentation (PSI) for treatment of distal intraarticular radius fractures. METHOD: 7 Patients who suffered a distal intraarticular radius fracture were enrolled in this prospective case series. Preoperative CT-scan was recorded, whereupon a 3D model was computed for surgical planning and design of PSI for surgical navigation. Postoperative accuracy and joint congruency were assessed. Patients were followed-up 3, 6 and 12 months postoperatively. RESULTS: Mean follow-up was 16 months. Over all range of motion was restored and flexion, extension and pronation showed significant recovery, p < 0.05. Biggest intraarticular joint step-off and gap reduced from average 2.49 (± 1.04) to 0.8 mm (± 0.44), p < 0.05 and 6.12 mm (± 1.04) to 2.21 mm (± 1.16), p < 0.05. Average grip strength restored (3–16 months) from 20.33 kg (± 7.12) to 39.3 kg (± 19.55) p < 0.05, 100% of the healthy contralateral side. 3D-accuracy for guided fragments was 2.07 mm (± 0.64) and 8.59° (± 2.9) and 2.33 mm (± 0.69) and 12.86° (± 7.13), p > 0.05 for fragments reduced with ligamentotaxis. CONCLUSION: Computer-assisted and PSI navigated intraarticular radius fracture treatment is feasible, safe and accurate. The benefits of this method, however, do not outstand the additional effort. LEVEL OF EVIDENCE: IV. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00402-021-03856-6. Springer Berlin Heidelberg 2021-03-14 2021 /pmc/articles/PMC8295140/ /pubmed/33715063 http://dx.doi.org/10.1007/s00402-021-03856-6 Text en © The Author(s) 2021, corrected publication 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Handsurgery Casari, F. A. Roner, S. Fürnstahl, P. Nagy, L. Schweizer, A. Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series |
title | Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series |
title_full | Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series |
title_fullStr | Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series |
title_full_unstemmed | Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series |
title_short | Computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series |
title_sort | computer-assisted open reduction internal fixation of intraarticular radius fractures navigated with patient-specific instrumentation, a prospective case series |
topic | Handsurgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8295140/ https://www.ncbi.nlm.nih.gov/pubmed/33715063 http://dx.doi.org/10.1007/s00402-021-03856-6 |
work_keys_str_mv | AT casarifa computerassistedopenreductioninternalfixationofintraarticularradiusfracturesnavigatedwithpatientspecificinstrumentationaprospectivecaseseries AT roners computerassistedopenreductioninternalfixationofintraarticularradiusfracturesnavigatedwithpatientspecificinstrumentationaprospectivecaseseries AT furnstahlp computerassistedopenreductioninternalfixationofintraarticularradiusfracturesnavigatedwithpatientspecificinstrumentationaprospectivecaseseries AT nagyl computerassistedopenreductioninternalfixationofintraarticularradiusfracturesnavigatedwithpatientspecificinstrumentationaprospectivecaseseries AT schweizera computerassistedopenreductioninternalfixationofintraarticularradiusfracturesnavigatedwithpatientspecificinstrumentationaprospectivecaseseries |