Cargando…

Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf

[Image: see text] The mining technology of gob-side entry retaining without a coal pillar is gradually becoming a mature and increasingly important mining technology. As it maintains the roadway near goaf, the air leakage should be greater than a U-type ventilation system in goaf, so it is prone to...

Descripción completa

Detalles Bibliográficos
Autores principales: Si, Junhong, Li, Lin, Cheng, Genyin, Shao, He, Wang, Yiqiao, Li, Zequan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8296586/
https://www.ncbi.nlm.nih.gov/pubmed/34308082
http://dx.doi.org/10.1021/acsomega.1c02836
_version_ 1783725672669118464
author Si, Junhong
Li, Lin
Cheng, Genyin
Shao, He
Wang, Yiqiao
Li, Zequan
author_facet Si, Junhong
Li, Lin
Cheng, Genyin
Shao, He
Wang, Yiqiao
Li, Zequan
author_sort Si, Junhong
collection PubMed
description [Image: see text] The mining technology of gob-side entry retaining without a coal pillar is gradually becoming a mature and increasingly important mining technology. As it maintains the roadway near goaf, the air leakage should be greater than a U-type ventilation system in goaf, so it is prone to cause coal spontaneous combustion problems. CO(2) is an inert gas, and it is usually used to prevent spontaneous combustion and extinguish coal fire. However, there is a lack of research on characteristics and safety of CO(2) for the mining technology of gob-side entry retaining without the coal pillar. In this paper, the indexes of influencing factors were proposed on gas, pipelines, and mining technical parameters. Using a three-dimensional physical model of coal stope, the gas migration law of CO(2), the relationship between gas injection rate and the oxidation zone area, and the safety of the CO(2) inerting technology were analyzed. The results indicate that the O(2) concentration is diluted between the working face and the injection port, especially in the air intake side. Furthermore, the CO(2) injection rate is an important parameter to the fire prevention and extinguishing technology. When the gas injection rate ranges from 240 to 720 m(3)/h, the oxidation zone area varies from 7380 to 14 760 m(2), and the gas injection rate grows exponentially with the area of the oxidation zone. Moreover, the redundant CO(2) gas flows to the retaining roadway, and it reduces the O(2) concentration, resulting in asphyxia accidents of miners. The research results are helpful to balance the relationship between inert gas injection and production safety and provide guidance for the practical application of the inert gas fire prevention technology.
format Online
Article
Text
id pubmed-8296586
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-82965862021-07-23 Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf Si, Junhong Li, Lin Cheng, Genyin Shao, He Wang, Yiqiao Li, Zequan ACS Omega [Image: see text] The mining technology of gob-side entry retaining without a coal pillar is gradually becoming a mature and increasingly important mining technology. As it maintains the roadway near goaf, the air leakage should be greater than a U-type ventilation system in goaf, so it is prone to cause coal spontaneous combustion problems. CO(2) is an inert gas, and it is usually used to prevent spontaneous combustion and extinguish coal fire. However, there is a lack of research on characteristics and safety of CO(2) for the mining technology of gob-side entry retaining without the coal pillar. In this paper, the indexes of influencing factors were proposed on gas, pipelines, and mining technical parameters. Using a three-dimensional physical model of coal stope, the gas migration law of CO(2), the relationship between gas injection rate and the oxidation zone area, and the safety of the CO(2) inerting technology were analyzed. The results indicate that the O(2) concentration is diluted between the working face and the injection port, especially in the air intake side. Furthermore, the CO(2) injection rate is an important parameter to the fire prevention and extinguishing technology. When the gas injection rate ranges from 240 to 720 m(3)/h, the oxidation zone area varies from 7380 to 14 760 m(2), and the gas injection rate grows exponentially with the area of the oxidation zone. Moreover, the redundant CO(2) gas flows to the retaining roadway, and it reduces the O(2) concentration, resulting in asphyxia accidents of miners. The research results are helpful to balance the relationship between inert gas injection and production safety and provide guidance for the practical application of the inert gas fire prevention technology. American Chemical Society 2021-07-08 /pmc/articles/PMC8296586/ /pubmed/34308082 http://dx.doi.org/10.1021/acsomega.1c02836 Text en © 2021 The Authors. Published by American Chemical Society Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Si, Junhong
Li, Lin
Cheng, Genyin
Shao, He
Wang, Yiqiao
Li, Zequan
Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf
title Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf
title_full Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf
title_fullStr Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf
title_full_unstemmed Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf
title_short Characteristics and Safety of CO(2) for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf
title_sort characteristics and safety of co(2) for the fire prevention technology with gob-side entry retaining in goaf
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8296586/
https://www.ncbi.nlm.nih.gov/pubmed/34308082
http://dx.doi.org/10.1021/acsomega.1c02836
work_keys_str_mv AT sijunhong characteristicsandsafetyofco2forthefirepreventiontechnologywithgobsideentryretainingingoaf
AT lilin characteristicsandsafetyofco2forthefirepreventiontechnologywithgobsideentryretainingingoaf
AT chenggenyin characteristicsandsafetyofco2forthefirepreventiontechnologywithgobsideentryretainingingoaf
AT shaohe characteristicsandsafetyofco2forthefirepreventiontechnologywithgobsideentryretainingingoaf
AT wangyiqiao characteristicsandsafetyofco2forthefirepreventiontechnologywithgobsideentryretainingingoaf
AT lizequan characteristicsandsafetyofco2forthefirepreventiontechnologywithgobsideentryretainingingoaf