The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation
PURPOSE: To assess measurement equivalence, inter- and intra-rater reliability, standard error of measurements (SEM) and false positive measurements (FPM) of four different knee arthrometers (KLT,Karl Storz; KiRA, I + ; KT-1000 MEDmetric Corp; Rolimeter, Aircast) in healthy patients. METHODS: Four d...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8298217/ https://www.ncbi.nlm.nih.gov/pubmed/33791824 http://dx.doi.org/10.1007/s00167-021-06540-9 |
_version_ | 1783726018251456512 |
---|---|
author | Runer, Armin Roberti di Sarsina, Tommaso Starke, Vasco Iltchev, Alessandra Felmet, Gernot Braun, Sepp Fink, Christian Csapo, Robert |
author_facet | Runer, Armin Roberti di Sarsina, Tommaso Starke, Vasco Iltchev, Alessandra Felmet, Gernot Braun, Sepp Fink, Christian Csapo, Robert |
author_sort | Runer, Armin |
collection | PubMed |
description | PURPOSE: To assess measurement equivalence, inter- and intra-rater reliability, standard error of measurements (SEM) and false positive measurements (FPM) of four different knee arthrometers (KLT,Karl Storz; KiRA, I + ; KT-1000 MEDmetric Corp; Rolimeter, Aircast) in healthy patients. METHODS: Four different investigators (two advanced (AR) and two beginners (BR)) examined 12 participants with healthy knees at two time points with regards to anterior tibial translation (ATT) and side-to-side difference (SSD). Test equivalence was assessed using the TOST (two-one-sided t test) procedure with ± 1 mm equivalence boundaries. Intraclass correlation coefficients (ICCs) were calculated using two-way mixed effects models. Furthermore, false positive-(SSD > 3 mm) and SEMs were assessed. RESULTS: A total of 2304 Lachman Tests were performed. Between-rater SSDs were equivalent between AR and BR raters for the Rolimeter only. Inter-rater ICC values (SSD, ATT) were graded as “poor” to “moderate” for all devices. Equivalent test–retest results were observed for all raters using the Rolimeter, KLT and KT-1000, whereas measurement consistency with KiRA was given in the advanced examiners group only. Intra-rater ICC values (Range: SSD, ATT) were graded as “poor” to “moderate” for SSD values and “moderate” to “good” for ATT. SEMs were lowest for the Rolimeter and highest for KiRA. FPM were never obtained with the Rolimeter (0%), twice (2.1%) with the KT-1000, three times (3.1%) with the KLT and 33 times (34.4%) using KiRA. CONCLUSION: There is acceptable intra-rater but poor inter-rater reliability with all tested arthrometers. Measures of knee laxity are comparable between Rolimeter, KLT and KT-1000 but higher for KiRA. Clinically, the present study shows that repeated arthrometry measurements should always be performed by the same investigators. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00167-021-06540-9. |
format | Online Article Text |
id | pubmed-8298217 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-82982172021-07-23 The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation Runer, Armin Roberti di Sarsina, Tommaso Starke, Vasco Iltchev, Alessandra Felmet, Gernot Braun, Sepp Fink, Christian Csapo, Robert Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: To assess measurement equivalence, inter- and intra-rater reliability, standard error of measurements (SEM) and false positive measurements (FPM) of four different knee arthrometers (KLT,Karl Storz; KiRA, I + ; KT-1000 MEDmetric Corp; Rolimeter, Aircast) in healthy patients. METHODS: Four different investigators (two advanced (AR) and two beginners (BR)) examined 12 participants with healthy knees at two time points with regards to anterior tibial translation (ATT) and side-to-side difference (SSD). Test equivalence was assessed using the TOST (two-one-sided t test) procedure with ± 1 mm equivalence boundaries. Intraclass correlation coefficients (ICCs) were calculated using two-way mixed effects models. Furthermore, false positive-(SSD > 3 mm) and SEMs were assessed. RESULTS: A total of 2304 Lachman Tests were performed. Between-rater SSDs were equivalent between AR and BR raters for the Rolimeter only. Inter-rater ICC values (SSD, ATT) were graded as “poor” to “moderate” for all devices. Equivalent test–retest results were observed for all raters using the Rolimeter, KLT and KT-1000, whereas measurement consistency with KiRA was given in the advanced examiners group only. Intra-rater ICC values (Range: SSD, ATT) were graded as “poor” to “moderate” for SSD values and “moderate” to “good” for ATT. SEMs were lowest for the Rolimeter and highest for KiRA. FPM were never obtained with the Rolimeter (0%), twice (2.1%) with the KT-1000, three times (3.1%) with the KLT and 33 times (34.4%) using KiRA. CONCLUSION: There is acceptable intra-rater but poor inter-rater reliability with all tested arthrometers. Measures of knee laxity are comparable between Rolimeter, KLT and KT-1000 but higher for KiRA. Clinically, the present study shows that repeated arthrometry measurements should always be performed by the same investigators. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00167-021-06540-9. Springer Berlin Heidelberg 2021-03-31 2021 /pmc/articles/PMC8298217/ /pubmed/33791824 http://dx.doi.org/10.1007/s00167-021-06540-9 Text en © The Author(s) 2021, corrected publication 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Knee Runer, Armin Roberti di Sarsina, Tommaso Starke, Vasco Iltchev, Alessandra Felmet, Gernot Braun, Sepp Fink, Christian Csapo, Robert The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation |
title | The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation |
title_full | The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation |
title_fullStr | The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation |
title_full_unstemmed | The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation |
title_short | The evaluation of Rolimeter, KLT, KiRA and KT-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation |
title_sort | evaluation of rolimeter, klt, kira and kt-1000 arthrometer in healthy individuals shows acceptable intra-rater but poor inter-rater reliability in the measurement of anterior tibial knee translation |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8298217/ https://www.ncbi.nlm.nih.gov/pubmed/33791824 http://dx.doi.org/10.1007/s00167-021-06540-9 |
work_keys_str_mv | AT runerarmin theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT robertidisarsinatommaso theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT starkevasco theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT iltchevalessandra theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT felmetgernot theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT braunsepp theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT finkchristian theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT csaporobert theevaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT runerarmin evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT robertidisarsinatommaso evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT starkevasco evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT iltchevalessandra evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT felmetgernot evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT braunsepp evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT finkchristian evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation AT csaporobert evaluationofrolimeterkltkiraandkt1000arthrometerinhealthyindividualsshowsacceptableintraraterbutpoorinterraterreliabilityinthemeasurementofanteriortibialkneetranslation |