Cargando…

The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola

PURPOSE: The cellular topography of the human foveola, the central 1° diameter of the fovea, is strikingly non-uniform, with a steep increase of cone photoreceptor density and outer segment (OS) length toward its center. Here, we assessed to what extent the specific cellular organization of the fove...

Descripción completa

Detalles Bibliográficos
Autores principales: Domdei, Niklas, Reiniger, Jenny L., Holz, Frank G., Harmening, Wolf M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8300048/
https://www.ncbi.nlm.nih.gov/pubmed/34289495
http://dx.doi.org/10.1167/iovs.62.9.31
_version_ 1783726383396028416
author Domdei, Niklas
Reiniger, Jenny L.
Holz, Frank G.
Harmening, Wolf M.
author_facet Domdei, Niklas
Reiniger, Jenny L.
Holz, Frank G.
Harmening, Wolf M.
author_sort Domdei, Niklas
collection PubMed
description PURPOSE: The cellular topography of the human foveola, the central 1° diameter of the fovea, is strikingly non-uniform, with a steep increase of cone photoreceptor density and outer segment (OS) length toward its center. Here, we assessed to what extent the specific cellular organization of the foveola of an individual is reflected in visual sensitivity and if sensitivity peaks at the preferred retinal locus of fixation (PRL). METHODS: Increment sensitivity to small-spot, cone-targeted visual stimuli (1 × 1 arcmin, 543-nm light) was recorded psychophysically in four human participants at 17 locations concentric within a 0.2° diameter on and around the PRL with adaptive optics scanning laser ophthalmoscopy-based microstimulation. Sensitivity test spots were aligned with cell-resolved maps of cone density and cone OS length. RESULTS: Peak sensitivity was at neither the PRL nor the topographical center of the cone mosaic. Within the central 0.1° diameter, a plateau-like sensitivity profile was observed. Cone density and maximal OS length differed significantly across participants, correlating with their peak sensitivity. Based on these results, biophysical simulation allowed to develop a model of visual sensitivity in the foveola, with distance from the PRL (eccentricity), cone density, and OS length as parameters. CONCLUSIONS: Small-spot sensitivity thresholds in healthy retinas will help to establish the range of normal foveolar function in cell-targeted vision testing. Because of the high reproducibility in replicate testing, threshold variability not explained by our model is assumed to be caused by individual cone and bipolar cell weighting at the specific target locations.
format Online
Article
Text
id pubmed-8300048
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-83000482021-07-28 The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola Domdei, Niklas Reiniger, Jenny L. Holz, Frank G. Harmening, Wolf M. Invest Ophthalmol Vis Sci Visual Psychophysics and Physiological Optics PURPOSE: The cellular topography of the human foveola, the central 1° diameter of the fovea, is strikingly non-uniform, with a steep increase of cone photoreceptor density and outer segment (OS) length toward its center. Here, we assessed to what extent the specific cellular organization of the foveola of an individual is reflected in visual sensitivity and if sensitivity peaks at the preferred retinal locus of fixation (PRL). METHODS: Increment sensitivity to small-spot, cone-targeted visual stimuli (1 × 1 arcmin, 543-nm light) was recorded psychophysically in four human participants at 17 locations concentric within a 0.2° diameter on and around the PRL with adaptive optics scanning laser ophthalmoscopy-based microstimulation. Sensitivity test spots were aligned with cell-resolved maps of cone density and cone OS length. RESULTS: Peak sensitivity was at neither the PRL nor the topographical center of the cone mosaic. Within the central 0.1° diameter, a plateau-like sensitivity profile was observed. Cone density and maximal OS length differed significantly across participants, correlating with their peak sensitivity. Based on these results, biophysical simulation allowed to develop a model of visual sensitivity in the foveola, with distance from the PRL (eccentricity), cone density, and OS length as parameters. CONCLUSIONS: Small-spot sensitivity thresholds in healthy retinas will help to establish the range of normal foveolar function in cell-targeted vision testing. Because of the high reproducibility in replicate testing, threshold variability not explained by our model is assumed to be caused by individual cone and bipolar cell weighting at the specific target locations. The Association for Research in Vision and Ophthalmology 2021-07-21 /pmc/articles/PMC8300048/ /pubmed/34289495 http://dx.doi.org/10.1167/iovs.62.9.31 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Visual Psychophysics and Physiological Optics
Domdei, Niklas
Reiniger, Jenny L.
Holz, Frank G.
Harmening, Wolf M.
The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola
title The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola
title_full The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola
title_fullStr The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola
title_full_unstemmed The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola
title_short The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola
title_sort relationship between visual sensitivity and eccentricity, cone density and outer segment length in the human foveola
topic Visual Psychophysics and Physiological Optics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8300048/
https://www.ncbi.nlm.nih.gov/pubmed/34289495
http://dx.doi.org/10.1167/iovs.62.9.31
work_keys_str_mv AT domdeiniklas therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola
AT reinigerjennyl therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola
AT holzfrankg therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola
AT harmeningwolfm therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola
AT domdeiniklas relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola
AT reinigerjennyl relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola
AT holzfrankg relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola
AT harmeningwolfm relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola