Cargando…
The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola
PURPOSE: The cellular topography of the human foveola, the central 1° diameter of the fovea, is strikingly non-uniform, with a steep increase of cone photoreceptor density and outer segment (OS) length toward its center. Here, we assessed to what extent the specific cellular organization of the fove...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8300048/ https://www.ncbi.nlm.nih.gov/pubmed/34289495 http://dx.doi.org/10.1167/iovs.62.9.31 |
_version_ | 1783726383396028416 |
---|---|
author | Domdei, Niklas Reiniger, Jenny L. Holz, Frank G. Harmening, Wolf M. |
author_facet | Domdei, Niklas Reiniger, Jenny L. Holz, Frank G. Harmening, Wolf M. |
author_sort | Domdei, Niklas |
collection | PubMed |
description | PURPOSE: The cellular topography of the human foveola, the central 1° diameter of the fovea, is strikingly non-uniform, with a steep increase of cone photoreceptor density and outer segment (OS) length toward its center. Here, we assessed to what extent the specific cellular organization of the foveola of an individual is reflected in visual sensitivity and if sensitivity peaks at the preferred retinal locus of fixation (PRL). METHODS: Increment sensitivity to small-spot, cone-targeted visual stimuli (1 × 1 arcmin, 543-nm light) was recorded psychophysically in four human participants at 17 locations concentric within a 0.2° diameter on and around the PRL with adaptive optics scanning laser ophthalmoscopy-based microstimulation. Sensitivity test spots were aligned with cell-resolved maps of cone density and cone OS length. RESULTS: Peak sensitivity was at neither the PRL nor the topographical center of the cone mosaic. Within the central 0.1° diameter, a plateau-like sensitivity profile was observed. Cone density and maximal OS length differed significantly across participants, correlating with their peak sensitivity. Based on these results, biophysical simulation allowed to develop a model of visual sensitivity in the foveola, with distance from the PRL (eccentricity), cone density, and OS length as parameters. CONCLUSIONS: Small-spot sensitivity thresholds in healthy retinas will help to establish the range of normal foveolar function in cell-targeted vision testing. Because of the high reproducibility in replicate testing, threshold variability not explained by our model is assumed to be caused by individual cone and bipolar cell weighting at the specific target locations. |
format | Online Article Text |
id | pubmed-8300048 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-83000482021-07-28 The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola Domdei, Niklas Reiniger, Jenny L. Holz, Frank G. Harmening, Wolf M. Invest Ophthalmol Vis Sci Visual Psychophysics and Physiological Optics PURPOSE: The cellular topography of the human foveola, the central 1° diameter of the fovea, is strikingly non-uniform, with a steep increase of cone photoreceptor density and outer segment (OS) length toward its center. Here, we assessed to what extent the specific cellular organization of the foveola of an individual is reflected in visual sensitivity and if sensitivity peaks at the preferred retinal locus of fixation (PRL). METHODS: Increment sensitivity to small-spot, cone-targeted visual stimuli (1 × 1 arcmin, 543-nm light) was recorded psychophysically in four human participants at 17 locations concentric within a 0.2° diameter on and around the PRL with adaptive optics scanning laser ophthalmoscopy-based microstimulation. Sensitivity test spots were aligned with cell-resolved maps of cone density and cone OS length. RESULTS: Peak sensitivity was at neither the PRL nor the topographical center of the cone mosaic. Within the central 0.1° diameter, a plateau-like sensitivity profile was observed. Cone density and maximal OS length differed significantly across participants, correlating with their peak sensitivity. Based on these results, biophysical simulation allowed to develop a model of visual sensitivity in the foveola, with distance from the PRL (eccentricity), cone density, and OS length as parameters. CONCLUSIONS: Small-spot sensitivity thresholds in healthy retinas will help to establish the range of normal foveolar function in cell-targeted vision testing. Because of the high reproducibility in replicate testing, threshold variability not explained by our model is assumed to be caused by individual cone and bipolar cell weighting at the specific target locations. The Association for Research in Vision and Ophthalmology 2021-07-21 /pmc/articles/PMC8300048/ /pubmed/34289495 http://dx.doi.org/10.1167/iovs.62.9.31 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Visual Psychophysics and Physiological Optics Domdei, Niklas Reiniger, Jenny L. Holz, Frank G. Harmening, Wolf M. The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola |
title | The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola |
title_full | The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola |
title_fullStr | The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola |
title_full_unstemmed | The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola |
title_short | The Relationship Between Visual Sensitivity and Eccentricity, Cone Density and Outer Segment Length in the Human Foveola |
title_sort | relationship between visual sensitivity and eccentricity, cone density and outer segment length in the human foveola |
topic | Visual Psychophysics and Physiological Optics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8300048/ https://www.ncbi.nlm.nih.gov/pubmed/34289495 http://dx.doi.org/10.1167/iovs.62.9.31 |
work_keys_str_mv | AT domdeiniklas therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola AT reinigerjennyl therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola AT holzfrankg therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola AT harmeningwolfm therelationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola AT domdeiniklas relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola AT reinigerjennyl relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola AT holzfrankg relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola AT harmeningwolfm relationshipbetweenvisualsensitivityandeccentricityconedensityandoutersegmentlengthinthehumanfoveola |