Cargando…

Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy

SIMPLE SUMMARY: In the Puna region of Argentina, llama fibre production has enormous social, economic and environmental potential, but is still in its early stages of development. For this reason, classification and quality analysis systems used today are still deficient. Near infrared reflectance s...

Descripción completa

Detalles Bibliográficos
Autores principales: Amorena, José Ignacio, Álvarez, Dolores María Eugenia, Fernández-Ahumada, Elvira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8300122/
https://www.ncbi.nlm.nih.gov/pubmed/34359126
http://dx.doi.org/10.3390/ani11071998
_version_ 1783726400329482240
author Amorena, José Ignacio
Álvarez, Dolores María Eugenia
Fernández-Ahumada, Elvira
author_facet Amorena, José Ignacio
Álvarez, Dolores María Eugenia
Fernández-Ahumada, Elvira
author_sort Amorena, José Ignacio
collection PubMed
description SIMPLE SUMMARY: In the Puna region of Argentina, llama fibre production has enormous social, economic and environmental potential, but is still in its early stages of development. For this reason, classification and quality analysis systems used today are still deficient. Near infrared reflectance spectroscopy is a technological resource used in the agroindustry for quality analysis of organic compounds. In this work we studied the feasibility of this technology to evaluate the mean fibre diameter, which is one of the most important quality parameters in the textile industry. Despite some limitations, which are mainly related to fibre heterogeneity, the results obtained were encouraging as spectroscopy could be used in screening programmes as a sustainable, fast and low-cost method to improve fibre quality validation. ABSTRACT: Llama fibre has the potential to become the most valuable textile resource in the Puna region of Argentina. In this study near infrared reflectance spectroscopy was evaluated to predict the mean fibre diameter in llama fleeces. Analyses between sets of carded and non-carded samples in combination with spectral preprocessing techniques were carried out and a total of 169 spectral signatures of llama samples in Vis and NIR ranges (400–2500 nm) were obtained. Spectral preprocessing consisted in wavelength selection (Vis–NIR, NIR and discrete ranges) and multiplicative and derivative pretreatments; spectra without pretreatments were also included, while modified partial least squares (M-PLS) regression was used to develop prediction models. Predictability was evaluated through R(2): standard cross validation error (SECV), external validation error (SEV) and residual predictive value (RPD). A total of 54 calibration models were developed in which the best model (R(2) = 0.67; SECV = 1.965; SEV = 2.235 and RPD = 1.91) was obtained in the Vis–NIR range applying the first derivative pretreatment. ANOVA analysis showed differences between carded and non-carded sets and the models obtained could be used in screening programs and contribute to valorisation of llama fibre and sustainable development of textile industry in the Puna territory of Catamarca. The data presented in this paper are a contribution to enhance the scarce information on this subject.
format Online
Article
Text
id pubmed-8300122
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83001222021-07-24 Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy Amorena, José Ignacio Álvarez, Dolores María Eugenia Fernández-Ahumada, Elvira Animals (Basel) Article SIMPLE SUMMARY: In the Puna region of Argentina, llama fibre production has enormous social, economic and environmental potential, but is still in its early stages of development. For this reason, classification and quality analysis systems used today are still deficient. Near infrared reflectance spectroscopy is a technological resource used in the agroindustry for quality analysis of organic compounds. In this work we studied the feasibility of this technology to evaluate the mean fibre diameter, which is one of the most important quality parameters in the textile industry. Despite some limitations, which are mainly related to fibre heterogeneity, the results obtained were encouraging as spectroscopy could be used in screening programmes as a sustainable, fast and low-cost method to improve fibre quality validation. ABSTRACT: Llama fibre has the potential to become the most valuable textile resource in the Puna region of Argentina. In this study near infrared reflectance spectroscopy was evaluated to predict the mean fibre diameter in llama fleeces. Analyses between sets of carded and non-carded samples in combination with spectral preprocessing techniques were carried out and a total of 169 spectral signatures of llama samples in Vis and NIR ranges (400–2500 nm) were obtained. Spectral preprocessing consisted in wavelength selection (Vis–NIR, NIR and discrete ranges) and multiplicative and derivative pretreatments; spectra without pretreatments were also included, while modified partial least squares (M-PLS) regression was used to develop prediction models. Predictability was evaluated through R(2): standard cross validation error (SECV), external validation error (SEV) and residual predictive value (RPD). A total of 54 calibration models were developed in which the best model (R(2) = 0.67; SECV = 1.965; SEV = 2.235 and RPD = 1.91) was obtained in the Vis–NIR range applying the first derivative pretreatment. ANOVA analysis showed differences between carded and non-carded sets and the models obtained could be used in screening programs and contribute to valorisation of llama fibre and sustainable development of textile industry in the Puna territory of Catamarca. The data presented in this paper are a contribution to enhance the scarce information on this subject. MDPI 2021-07-04 /pmc/articles/PMC8300122/ /pubmed/34359126 http://dx.doi.org/10.3390/ani11071998 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Amorena, José Ignacio
Álvarez, Dolores María Eugenia
Fernández-Ahumada, Elvira
Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy
title Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy
title_full Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy
title_fullStr Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy
title_full_unstemmed Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy
title_short Development of Calibration Models to Predict Mean Fibre Diameter in Llama (Lama glama) Fleeces with Near Infrared Spectroscopy
title_sort development of calibration models to predict mean fibre diameter in llama (lama glama) fleeces with near infrared spectroscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8300122/
https://www.ncbi.nlm.nih.gov/pubmed/34359126
http://dx.doi.org/10.3390/ani11071998
work_keys_str_mv AT amorenajoseignacio developmentofcalibrationmodelstopredictmeanfibrediameterinllamalamaglamafleeceswithnearinfraredspectroscopy
AT alvarezdoloresmariaeugenia developmentofcalibrationmodelstopredictmeanfibrediameterinllamalamaglamafleeceswithnearinfraredspectroscopy
AT fernandezahumadaelvira developmentofcalibrationmodelstopredictmeanfibrediameterinllamalamaglamafleeceswithnearinfraredspectroscopy