Cargando…

Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk

Antimicrobial drug residues in food are strictly controlled and monitored by national laws in most territories. Tetracyclines are a major broad-spectrum antibiotic class, active against a wide range of Gram-positive and Gram-negative bacteria, and they are the leading choice for the treatment of man...

Descripción completa

Detalles Bibliográficos
Autores principales: Raykova, Magdalena R., Corrigan, Damion K., Holdsworth, Morag, Henriquez, Fiona L., Ward, Andrew C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301834/
https://www.ncbi.nlm.nih.gov/pubmed/34356702
http://dx.doi.org/10.3390/bios11070232
_version_ 1783726762861002752
author Raykova, Magdalena R.
Corrigan, Damion K.
Holdsworth, Morag
Henriquez, Fiona L.
Ward, Andrew C.
author_facet Raykova, Magdalena R.
Corrigan, Damion K.
Holdsworth, Morag
Henriquez, Fiona L.
Ward, Andrew C.
author_sort Raykova, Magdalena R.
collection PubMed
description Antimicrobial drug residues in food are strictly controlled and monitored by national laws in most territories. Tetracyclines are a major broad-spectrum antibiotic class, active against a wide range of Gram-positive and Gram-negative bacteria, and they are the leading choice for the treatment of many conditions in veterinary medicine in recent years. In dairy farms, milk from cows being treated with antibiotic drugs, such as tetracyclines, is considered unfit for human consumption. Contamination of the farm bulk tank with milk containing these residues presents a threat to confidence of supply and results in financial losses to farmers and dairy. Real-time monitoring of milk production for antimicrobial residues could reduce this risk and help to minimise the release of residues into the environment where they can cause reservoirs of antimicrobial resistance. In this article, we review the existing literature for the detection of tetracyclines in cow’s milk. Firstly, the complex nature of the milk matrix is described, and the test strategies in commercial use are outlined. Following this, emerging biosensors in the low-cost biosensors field are contrasted against each other, focusing upon electrochemical biosensors. Existing commercial tests that identify antimicrobial residues within milk are largely limited to beta-lactam detection, or non-specific detection of microbial inhibition, with tests specific to tetracycline residues less prevalent. Herein, we review a number of emerging electrochemical biosensor detection strategies for tetracyclines, which have the potential to close this gap and address the industry challenges associated with existing tests.
format Online
Article
Text
id pubmed-8301834
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83018342021-07-24 Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk Raykova, Magdalena R. Corrigan, Damion K. Holdsworth, Morag Henriquez, Fiona L. Ward, Andrew C. Biosensors (Basel) Review Antimicrobial drug residues in food are strictly controlled and monitored by national laws in most territories. Tetracyclines are a major broad-spectrum antibiotic class, active against a wide range of Gram-positive and Gram-negative bacteria, and they are the leading choice for the treatment of many conditions in veterinary medicine in recent years. In dairy farms, milk from cows being treated with antibiotic drugs, such as tetracyclines, is considered unfit for human consumption. Contamination of the farm bulk tank with milk containing these residues presents a threat to confidence of supply and results in financial losses to farmers and dairy. Real-time monitoring of milk production for antimicrobial residues could reduce this risk and help to minimise the release of residues into the environment where they can cause reservoirs of antimicrobial resistance. In this article, we review the existing literature for the detection of tetracyclines in cow’s milk. Firstly, the complex nature of the milk matrix is described, and the test strategies in commercial use are outlined. Following this, emerging biosensors in the low-cost biosensors field are contrasted against each other, focusing upon electrochemical biosensors. Existing commercial tests that identify antimicrobial residues within milk are largely limited to beta-lactam detection, or non-specific detection of microbial inhibition, with tests specific to tetracycline residues less prevalent. Herein, we review a number of emerging electrochemical biosensor detection strategies for tetracyclines, which have the potential to close this gap and address the industry challenges associated with existing tests. MDPI 2021-07-09 /pmc/articles/PMC8301834/ /pubmed/34356702 http://dx.doi.org/10.3390/bios11070232 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Raykova, Magdalena R.
Corrigan, Damion K.
Holdsworth, Morag
Henriquez, Fiona L.
Ward, Andrew C.
Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk
title Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk
title_full Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk
title_fullStr Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk
title_full_unstemmed Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk
title_short Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk
title_sort emerging electrochemical sensors for real-time detection of tetracyclines in milk
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301834/
https://www.ncbi.nlm.nih.gov/pubmed/34356702
http://dx.doi.org/10.3390/bios11070232
work_keys_str_mv AT raykovamagdalenar emergingelectrochemicalsensorsforrealtimedetectionoftetracyclinesinmilk
AT corrigandamionk emergingelectrochemicalsensorsforrealtimedetectionoftetracyclinesinmilk
AT holdsworthmorag emergingelectrochemicalsensorsforrealtimedetectionoftetracyclinesinmilk
AT henriquezfional emergingelectrochemicalsensorsforrealtimedetectionoftetracyclinesinmilk
AT wardandrewc emergingelectrochemicalsensorsforrealtimedetectionoftetracyclinesinmilk