Cargando…

Wearable Intracranial Pressure Monitoring Sensor for Infants

Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To dat...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Baoyue, Huang, Ziyi, Song, Huixue, Kim, Hyun Soo, Park, Jaewon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301997/
https://www.ncbi.nlm.nih.gov/pubmed/34210050
http://dx.doi.org/10.3390/bios11070213
_version_ 1783726801611128832
author Zhang, Baoyue
Huang, Ziyi
Song, Huixue
Kim, Hyun Soo
Park, Jaewon
author_facet Zhang, Baoyue
Huang, Ziyi
Song, Huixue
Kim, Hyun Soo
Park, Jaewon
author_sort Zhang, Baoyue
collection PubMed
description Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R(2) > 0.9990) with the applied pressures.
format Online
Article
Text
id pubmed-8301997
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83019972021-07-24 Wearable Intracranial Pressure Monitoring Sensor for Infants Zhang, Baoyue Huang, Ziyi Song, Huixue Kim, Hyun Soo Park, Jaewon Biosensors (Basel) Article Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R(2) > 0.9990) with the applied pressures. MDPI 2021-06-29 /pmc/articles/PMC8301997/ /pubmed/34210050 http://dx.doi.org/10.3390/bios11070213 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Baoyue
Huang, Ziyi
Song, Huixue
Kim, Hyun Soo
Park, Jaewon
Wearable Intracranial Pressure Monitoring Sensor for Infants
title Wearable Intracranial Pressure Monitoring Sensor for Infants
title_full Wearable Intracranial Pressure Monitoring Sensor for Infants
title_fullStr Wearable Intracranial Pressure Monitoring Sensor for Infants
title_full_unstemmed Wearable Intracranial Pressure Monitoring Sensor for Infants
title_short Wearable Intracranial Pressure Monitoring Sensor for Infants
title_sort wearable intracranial pressure monitoring sensor for infants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301997/
https://www.ncbi.nlm.nih.gov/pubmed/34210050
http://dx.doi.org/10.3390/bios11070213
work_keys_str_mv AT zhangbaoyue wearableintracranialpressuremonitoringsensorforinfants
AT huangziyi wearableintracranialpressuremonitoringsensorforinfants
AT songhuixue wearableintracranialpressuremonitoringsensorforinfants
AT kimhyunsoo wearableintracranialpressuremonitoringsensorforinfants
AT parkjaewon wearableintracranialpressuremonitoringsensorforinfants