Cargando…
Wearable Intracranial Pressure Monitoring Sensor for Infants
Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To dat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301997/ https://www.ncbi.nlm.nih.gov/pubmed/34210050 http://dx.doi.org/10.3390/bios11070213 |
_version_ | 1783726801611128832 |
---|---|
author | Zhang, Baoyue Huang, Ziyi Song, Huixue Kim, Hyun Soo Park, Jaewon |
author_facet | Zhang, Baoyue Huang, Ziyi Song, Huixue Kim, Hyun Soo Park, Jaewon |
author_sort | Zhang, Baoyue |
collection | PubMed |
description | Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R(2) > 0.9990) with the applied pressures. |
format | Online Article Text |
id | pubmed-8301997 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83019972021-07-24 Wearable Intracranial Pressure Monitoring Sensor for Infants Zhang, Baoyue Huang, Ziyi Song, Huixue Kim, Hyun Soo Park, Jaewon Biosensors (Basel) Article Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R(2) > 0.9990) with the applied pressures. MDPI 2021-06-29 /pmc/articles/PMC8301997/ /pubmed/34210050 http://dx.doi.org/10.3390/bios11070213 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, Baoyue Huang, Ziyi Song, Huixue Kim, Hyun Soo Park, Jaewon Wearable Intracranial Pressure Monitoring Sensor for Infants |
title | Wearable Intracranial Pressure Monitoring Sensor for Infants |
title_full | Wearable Intracranial Pressure Monitoring Sensor for Infants |
title_fullStr | Wearable Intracranial Pressure Monitoring Sensor for Infants |
title_full_unstemmed | Wearable Intracranial Pressure Monitoring Sensor for Infants |
title_short | Wearable Intracranial Pressure Monitoring Sensor for Infants |
title_sort | wearable intracranial pressure monitoring sensor for infants |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8301997/ https://www.ncbi.nlm.nih.gov/pubmed/34210050 http://dx.doi.org/10.3390/bios11070213 |
work_keys_str_mv | AT zhangbaoyue wearableintracranialpressuremonitoringsensorforinfants AT huangziyi wearableintracranialpressuremonitoringsensorforinfants AT songhuixue wearableintracranialpressuremonitoringsensorforinfants AT kimhyunsoo wearableintracranialpressuremonitoringsensorforinfants AT parkjaewon wearableintracranialpressuremonitoringsensorforinfants |