A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty
The aim of this study was to describe a novel device for improved visualization of descemet membrane (DM) during donor preparation for descemet membrane endothelial keratoplasty (DMEK). Comparative analysis was performed using this device (group 1) versus conventional technique (group 2) between an...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8302293/ https://www.ncbi.nlm.nih.gov/pubmed/34011752 http://dx.doi.org/10.4103/ijo.IJO_2628_20 |
_version_ | 1783726858869669888 |
---|---|
author | Fogla, Rajesh |
author_facet | Fogla, Rajesh |
author_sort | Fogla, Rajesh |
collection | PubMed |
description | The aim of this study was to describe a novel device for improved visualization of descemet membrane (DM) during donor preparation for descemet membrane endothelial keratoplasty (DMEK). Comparative analysis was performed using this device (group 1) versus conventional technique (group 2) between an experienced and a trainee surgeon. A total of 20 eyes were analyzed in each group. Average time for DM peeling by experienced surgeon was 238.8 + 17.2 s in group 1 and 382.8 + 36.3 s in group 2 (P < 0.0001), and for trainee surgeon it was 519 + 30.8 s and 686.8 + 31.9 s (P < 0.0001). Retro-illumination made it easier to identify the peripheral cut edge of DM and abnormal adhesions to the underlying stroma during peeling. In group 2, DM tear occurred in 2/10 eyes with an experienced surgeon and 4/10 eyes with a trainee surgeon. Our novel device with retro-illumination allows DM peeling for donor preparation in DMEK to be performed safely with reduced risk of tissue damage. |
format | Online Article Text |
id | pubmed-8302293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-83022932021-08-02 A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty Fogla, Rajesh Indian J Ophthalmol Surgical Technique The aim of this study was to describe a novel device for improved visualization of descemet membrane (DM) during donor preparation for descemet membrane endothelial keratoplasty (DMEK). Comparative analysis was performed using this device (group 1) versus conventional technique (group 2) between an experienced and a trainee surgeon. A total of 20 eyes were analyzed in each group. Average time for DM peeling by experienced surgeon was 238.8 + 17.2 s in group 1 and 382.8 + 36.3 s in group 2 (P < 0.0001), and for trainee surgeon it was 519 + 30.8 s and 686.8 + 31.9 s (P < 0.0001). Retro-illumination made it easier to identify the peripheral cut edge of DM and abnormal adhesions to the underlying stroma during peeling. In group 2, DM tear occurred in 2/10 eyes with an experienced surgeon and 4/10 eyes with a trainee surgeon. Our novel device with retro-illumination allows DM peeling for donor preparation in DMEK to be performed safely with reduced risk of tissue damage. Wolters Kluwer - Medknow 2021-06 2021-05-21 /pmc/articles/PMC8302293/ /pubmed/34011752 http://dx.doi.org/10.4103/ijo.IJO_2628_20 Text en Copyright: © 2021 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Surgical Technique Fogla, Rajesh A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty |
title | A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty |
title_full | A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty |
title_fullStr | A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty |
title_full_unstemmed | A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty |
title_short | A novel device to visualize Descemet membrane during donor preparation for Descemet membrane endothelial keratoplasty |
title_sort | novel device to visualize descemet membrane during donor preparation for descemet membrane endothelial keratoplasty |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8302293/ https://www.ncbi.nlm.nih.gov/pubmed/34011752 http://dx.doi.org/10.4103/ijo.IJO_2628_20 |
work_keys_str_mv | AT foglarajesh anoveldevicetovisualizedescemetmembraneduringdonorpreparationfordescemetmembraneendothelialkeratoplasty AT foglarajesh noveldevicetovisualizedescemetmembraneduringdonorpreparationfordescemetmembraneendothelialkeratoplasty |