Cargando…
Bailout From Sinus Jailing: In-Series TAVR-in-TAVR to Avoid Coronary Flow Obstruction
Redo transcatheter aortic valve replacement (TAVR) may pose the risk of coronary flow obstruction. We report 2 cases of severe TAVR regurgitation due to different physiopathological mechanisms in which TAVR-in-TAVR could be at high risk for sinus sequestration. Both cases were successfully treated b...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8302790/ https://www.ncbi.nlm.nih.gov/pubmed/34317602 http://dx.doi.org/10.1016/j.jaccas.2021.02.022 |
Sumario: | Redo transcatheter aortic valve replacement (TAVR) may pose the risk of coronary flow obstruction. We report 2 cases of severe TAVR regurgitation due to different physiopathological mechanisms in which TAVR-in-TAVR could be at high risk for sinus sequestration. Both cases were successfully treated by in-series implantation of a second transcatheter heart valve, thus avoiding sinus sequestration. (Level of Difficulty: Intermediate.) |
---|