Cargando…
Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor
Anastomotic leakage (AL) is a common and dangerous post-operative complication following intestinal resection, causing substantial morbidity and mortality. Ischaemia in the tissue surrounding the anastomosis is a major risk-factor for AL development. Continuous tissue oxygenation monitoring during t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8303214/ https://www.ncbi.nlm.nih.gov/pubmed/34357220 http://dx.doi.org/10.3390/mi12070810 |
_version_ | 1783727033144049664 |
---|---|
author | Marland, Jamie R. K. Gray, Mark E. Argyle, David J. Underwood, Ian Murray, Alan F. Potter, Mark A. |
author_facet | Marland, Jamie R. K. Gray, Mark E. Argyle, David J. Underwood, Ian Murray, Alan F. Potter, Mark A. |
author_sort | Marland, Jamie R. K. |
collection | PubMed |
description | Anastomotic leakage (AL) is a common and dangerous post-operative complication following intestinal resection, causing substantial morbidity and mortality. Ischaemia in the tissue surrounding the anastomosis is a major risk-factor for AL development. Continuous tissue oxygenation monitoring during the post-operative recovery period would provide early and accurate early identification of AL risk. We describe the construction and testing of a miniature implantable electrochemical oxygen sensor that addresses this need. It consisted of an array of platinum microelectrodes, microfabricated on a silicon substrate, with a poly(2-hydroxyethyl methacrylate) hydrogel membrane to protect the sensor surface. The sensor was encapsulated in a biocompatible package with a wired connection to external instrumentation. It gave a sensitive and highly linear response to variations in oxygen partial pressure in vitro, although over time its sensitivity was partially decreased by protein biofouling. Using a pre-clinical in vivo pig model, acute intestinal ischaemia was robustly and accurately detected by the sensor. Graded changes in tissue oxygenation were also measurable, with relative differences detected more accurately than absolute differences. Finally, we demonstrated its suitability for continuous monitoring of tissue oxygenation at a colorectal anastomosis over a period of at least 45 h. This study provides evidence to support the development and use of implantable electrochemical oxygen sensors for post-operative monitoring of anastomosis oxygenation. |
format | Online Article Text |
id | pubmed-8303214 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83032142021-07-25 Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor Marland, Jamie R. K. Gray, Mark E. Argyle, David J. Underwood, Ian Murray, Alan F. Potter, Mark A. Micromachines (Basel) Article Anastomotic leakage (AL) is a common and dangerous post-operative complication following intestinal resection, causing substantial morbidity and mortality. Ischaemia in the tissue surrounding the anastomosis is a major risk-factor for AL development. Continuous tissue oxygenation monitoring during the post-operative recovery period would provide early and accurate early identification of AL risk. We describe the construction and testing of a miniature implantable electrochemical oxygen sensor that addresses this need. It consisted of an array of platinum microelectrodes, microfabricated on a silicon substrate, with a poly(2-hydroxyethyl methacrylate) hydrogel membrane to protect the sensor surface. The sensor was encapsulated in a biocompatible package with a wired connection to external instrumentation. It gave a sensitive and highly linear response to variations in oxygen partial pressure in vitro, although over time its sensitivity was partially decreased by protein biofouling. Using a pre-clinical in vivo pig model, acute intestinal ischaemia was robustly and accurately detected by the sensor. Graded changes in tissue oxygenation were also measurable, with relative differences detected more accurately than absolute differences. Finally, we demonstrated its suitability for continuous monitoring of tissue oxygenation at a colorectal anastomosis over a period of at least 45 h. This study provides evidence to support the development and use of implantable electrochemical oxygen sensors for post-operative monitoring of anastomosis oxygenation. MDPI 2021-07-10 /pmc/articles/PMC8303214/ /pubmed/34357220 http://dx.doi.org/10.3390/mi12070810 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Marland, Jamie R. K. Gray, Mark E. Argyle, David J. Underwood, Ian Murray, Alan F. Potter, Mark A. Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor |
title | Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor |
title_full | Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor |
title_fullStr | Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor |
title_full_unstemmed | Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor |
title_short | Post-Operative Monitoring of Intestinal Tissue Oxygenation Using an Implantable Microfabricated Oxygen Sensor |
title_sort | post-operative monitoring of intestinal tissue oxygenation using an implantable microfabricated oxygen sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8303214/ https://www.ncbi.nlm.nih.gov/pubmed/34357220 http://dx.doi.org/10.3390/mi12070810 |
work_keys_str_mv | AT marlandjamierk postoperativemonitoringofintestinaltissueoxygenationusinganimplantablemicrofabricatedoxygensensor AT graymarke postoperativemonitoringofintestinaltissueoxygenationusinganimplantablemicrofabricatedoxygensensor AT argyledavidj postoperativemonitoringofintestinaltissueoxygenationusinganimplantablemicrofabricatedoxygensensor AT underwoodian postoperativemonitoringofintestinaltissueoxygenationusinganimplantablemicrofabricatedoxygensensor AT murrayalanf postoperativemonitoringofintestinaltissueoxygenationusinganimplantablemicrofabricatedoxygensensor AT pottermarka postoperativemonitoringofintestinaltissueoxygenationusinganimplantablemicrofabricatedoxygensensor |