Cargando…

Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate

Phosphate and aluminate electrolytes were used to prepare plasma electrolytic oxidation (PEO) coatings on 6061 aluminum alloy. The surface and cross-section microstructure, element distribution, and phase composition of the PEO coatings were characterized by SEM, EDS, XPS, and XRD. The friction and...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Zhenjun, Xu, Hui, Liu, Siqin, Qi, Yuming, Liang, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8303336/
https://www.ncbi.nlm.nih.gov/pubmed/34300956
http://dx.doi.org/10.3390/ma14144037
_version_ 1783727062338502656
author Peng, Zhenjun
Xu, Hui
Liu, Siqin
Qi, Yuming
Liang, Jun
author_facet Peng, Zhenjun
Xu, Hui
Liu, Siqin
Qi, Yuming
Liang, Jun
author_sort Peng, Zhenjun
collection PubMed
description Phosphate and aluminate electrolytes were used to prepare plasma electrolytic oxidation (PEO) coatings on 6061 aluminum alloy. The surface and cross-section microstructure, element distribution, and phase composition of the PEO coatings were characterized by SEM, EDS, XPS, and XRD. The friction and wear properties were evaluated by pin-on-disk sliding tests under dry conditions. The corrosion resistance of PEO coatings was investigated by electrochemical corrosion and salt spray tests in acidic environments. It was found that the PEO coatings prepared from both phosphate and aluminate electrolytes were mainly composed of α-Al(2)O(3) and γ-Al(2)O(3). The results demonstrate that a bi-layer coating is formed in the phosphate electrolyte, and a single-layered dense alumina coating with a hardness of 1300 HV is realizable in the aluminate electrolyte. The aluminate PEO coating had a lower wear rate than the phosphate PEO coating. However, the phosphate PEO coating showed a better corrosion resistance in acidic environment, which is mainly attributed to the presence of an amorphous P element at the substrate/coating interface.
format Online
Article
Text
id pubmed-8303336
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83033362021-07-25 Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate Peng, Zhenjun Xu, Hui Liu, Siqin Qi, Yuming Liang, Jun Materials (Basel) Article Phosphate and aluminate electrolytes were used to prepare plasma electrolytic oxidation (PEO) coatings on 6061 aluminum alloy. The surface and cross-section microstructure, element distribution, and phase composition of the PEO coatings were characterized by SEM, EDS, XPS, and XRD. The friction and wear properties were evaluated by pin-on-disk sliding tests under dry conditions. The corrosion resistance of PEO coatings was investigated by electrochemical corrosion and salt spray tests in acidic environments. It was found that the PEO coatings prepared from both phosphate and aluminate electrolytes were mainly composed of α-Al(2)O(3) and γ-Al(2)O(3). The results demonstrate that a bi-layer coating is formed in the phosphate electrolyte, and a single-layered dense alumina coating with a hardness of 1300 HV is realizable in the aluminate electrolyte. The aluminate PEO coating had a lower wear rate than the phosphate PEO coating. However, the phosphate PEO coating showed a better corrosion resistance in acidic environment, which is mainly attributed to the presence of an amorphous P element at the substrate/coating interface. MDPI 2021-07-19 /pmc/articles/PMC8303336/ /pubmed/34300956 http://dx.doi.org/10.3390/ma14144037 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Peng, Zhenjun
Xu, Hui
Liu, Siqin
Qi, Yuming
Liang, Jun
Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate
title Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate
title_full Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate
title_fullStr Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate
title_full_unstemmed Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate
title_short Wear and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on 6061 Al Alloy in Electrolytes with Aluminate and Phosphate
title_sort wear and corrosion resistance of plasma electrolytic oxidation coatings on 6061 al alloy in electrolytes with aluminate and phosphate
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8303336/
https://www.ncbi.nlm.nih.gov/pubmed/34300956
http://dx.doi.org/10.3390/ma14144037
work_keys_str_mv AT pengzhenjun wearandcorrosionresistanceofplasmaelectrolyticoxidationcoatingson6061alalloyinelectrolyteswithaluminateandphosphate
AT xuhui wearandcorrosionresistanceofplasmaelectrolyticoxidationcoatingson6061alalloyinelectrolyteswithaluminateandphosphate
AT liusiqin wearandcorrosionresistanceofplasmaelectrolyticoxidationcoatingson6061alalloyinelectrolyteswithaluminateandphosphate
AT qiyuming wearandcorrosionresistanceofplasmaelectrolyticoxidationcoatingson6061alalloyinelectrolyteswithaluminateandphosphate
AT liangjun wearandcorrosionresistanceofplasmaelectrolyticoxidationcoatingson6061alalloyinelectrolyteswithaluminateandphosphate