Cargando…

Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry

Hand held dynamometers (HHDs) are the most used method to measure strength in clinical sitting. There are two methods to realize the assessment: pull and push. The purpose of the present study was to evaluate the intra- and inter-rater reliability of a new measurement modality for pull HHD and to co...

Descripción completa

Detalles Bibliográficos
Autores principales: González-Rosalén, Javier, Benítez-Martínez, Josep Carles, Medina-Mirapeix, Francesc, Cuerda-Del Pino, Alba, Cervelló, Antonio, Martín-San Agustín, Rodrigo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8303393/
https://www.ncbi.nlm.nih.gov/pubmed/34359313
http://dx.doi.org/10.3390/diagnostics11071230
_version_ 1783727076177608704
author González-Rosalén, Javier
Benítez-Martínez, Josep Carles
Medina-Mirapeix, Francesc
Cuerda-Del Pino, Alba
Cervelló, Antonio
Martín-San Agustín, Rodrigo
author_facet González-Rosalén, Javier
Benítez-Martínez, Josep Carles
Medina-Mirapeix, Francesc
Cuerda-Del Pino, Alba
Cervelló, Antonio
Martín-San Agustín, Rodrigo
author_sort González-Rosalén, Javier
collection PubMed
description Hand held dynamometers (HHDs) are the most used method to measure strength in clinical sitting. There are two methods to realize the assessment: pull and push. The purpose of the present study was to evaluate the intra- and inter-rater reliability of a new measurement modality for pull HHD and to compare the inter-rater reliability and agreement of the measurements. Forty healthy subjects were evaluated by two assessors with different body composition and manual strength. Fifteen isometric tests were performed in two sessions with a one-week interval between them. Reliability was examined using the intra-class correlation (ICC) and the standard error of measurement (SEM). Agreement between raters was examined using paired t-tests. Intra- and inter-rater reliability for the tests performed with the pull HHD showed excellent values, with ICCs ranging from 0.991 to 0.998. For tests with values higher than 200 N, push HHD showed greater differences between raters than pull HHD. Pull HHD attached to the examiner’s body is a method with excellent reliability to measure isometric strength and showed better agreement between examiners, especially for those tests that showed high levels of strength. Pull HHD is a new alternative to perform isometric tests with less rater dependence.
format Online
Article
Text
id pubmed-8303393
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83033932021-07-25 Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry González-Rosalén, Javier Benítez-Martínez, Josep Carles Medina-Mirapeix, Francesc Cuerda-Del Pino, Alba Cervelló, Antonio Martín-San Agustín, Rodrigo Diagnostics (Basel) Article Hand held dynamometers (HHDs) are the most used method to measure strength in clinical sitting. There are two methods to realize the assessment: pull and push. The purpose of the present study was to evaluate the intra- and inter-rater reliability of a new measurement modality for pull HHD and to compare the inter-rater reliability and agreement of the measurements. Forty healthy subjects were evaluated by two assessors with different body composition and manual strength. Fifteen isometric tests were performed in two sessions with a one-week interval between them. Reliability was examined using the intra-class correlation (ICC) and the standard error of measurement (SEM). Agreement between raters was examined using paired t-tests. Intra- and inter-rater reliability for the tests performed with the pull HHD showed excellent values, with ICCs ranging from 0.991 to 0.998. For tests with values higher than 200 N, push HHD showed greater differences between raters than pull HHD. Pull HHD attached to the examiner’s body is a method with excellent reliability to measure isometric strength and showed better agreement between examiners, especially for those tests that showed high levels of strength. Pull HHD is a new alternative to perform isometric tests with less rater dependence. MDPI 2021-07-08 /pmc/articles/PMC8303393/ /pubmed/34359313 http://dx.doi.org/10.3390/diagnostics11071230 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
González-Rosalén, Javier
Benítez-Martínez, Josep Carles
Medina-Mirapeix, Francesc
Cuerda-Del Pino, Alba
Cervelló, Antonio
Martín-San Agustín, Rodrigo
Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry
title Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry
title_full Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry
title_fullStr Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry
title_full_unstemmed Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry
title_short Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry
title_sort intra- and inter-rater reliability of strength measurements using a pull hand-held dynamometer fixed to the examiner’s body and comparison with push dynamometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8303393/
https://www.ncbi.nlm.nih.gov/pubmed/34359313
http://dx.doi.org/10.3390/diagnostics11071230
work_keys_str_mv AT gonzalezrosalenjavier intraandinterraterreliabilityofstrengthmeasurementsusingapullhandhelddynamometerfixedtotheexaminersbodyandcomparisonwithpushdynamometry
AT benitezmartinezjosepcarles intraandinterraterreliabilityofstrengthmeasurementsusingapullhandhelddynamometerfixedtotheexaminersbodyandcomparisonwithpushdynamometry
AT medinamirapeixfrancesc intraandinterraterreliabilityofstrengthmeasurementsusingapullhandhelddynamometerfixedtotheexaminersbodyandcomparisonwithpushdynamometry
AT cuerdadelpinoalba intraandinterraterreliabilityofstrengthmeasurementsusingapullhandhelddynamometerfixedtotheexaminersbodyandcomparisonwithpushdynamometry
AT cervelloantonio intraandinterraterreliabilityofstrengthmeasurementsusingapullhandhelddynamometerfixedtotheexaminersbodyandcomparisonwithpushdynamometry
AT martinsanagustinrodrigo intraandinterraterreliabilityofstrengthmeasurementsusingapullhandhelddynamometerfixedtotheexaminersbodyandcomparisonwithpushdynamometry