Cargando…

Q-Switched 1064/532 nm Laser with Nanosecond Pulse in Tattoo Treatment: A Double-Center Retrospective Study

Tattoo removal is a well-established procedure in dermatology. Lasers represent the gold standard in the management of this condition nowadays. In this study, we report our experience on the use of a Q-switched nanosecond source. A total of 52 patients were consecutively enrolled in performing tatto...

Descripción completa

Detalles Bibliográficos
Autores principales: Cannarozzo, Giovanni, Nisticò, Steven Paul, Zappia, Elena, Del Duca, Ester, Provenzano, Eugenio, Patruno, Cataldo, Negosanti, Francesca, Sannino, Mario, Bennardo, Luigi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8304052/
https://www.ncbi.nlm.nih.gov/pubmed/34357071
http://dx.doi.org/10.3390/life11070699
Descripción
Sumario:Tattoo removal is a well-established procedure in dermatology. Lasers represent the gold standard in the management of this condition nowadays. In this study, we report our experience on the use of a Q-switched nanosecond source. A total of 52 patients were consecutively enrolled in performing tattoo removal at Magna Graecia University of Catanzaro and Tor Vergata University of Rome. Black and blue tattoos were treated with a 1064 nm laser, with a pulse duration of 6 ns and a fluence up to 10 J/cm(2), while colored tattoos were treated with sessions of 532 nm laser, with a pulse duration of 6 ns and a fluence up to 5 J/cm(2). Up to nine treatments with a minimum interval of 8 weeks between each session were performed. A six-month follow-up visit assessed patient satisfaction (Visual Analogue Scale). Overall clinical result was assessed with a clinical evaluation by two blinded dermatologists using a 5-point scale, comparing pictures before treatment and at follow up. A total of 52 patients were included and analyzed: 30 females (57.7%) and 22 males (42.3%). Mean age was 43.7 ± 12.7 years. According to Fitzpatrick’s skin classification, 16 individuals (30.8%) were type II, 15 (28.8%) were type III, and 21 (40.4%) were type IV. Most of the treated tattoos were carried out by professionals. The mean number of sessions required to obtain a result was 4.6 ± 2.5, and the final tattoo removal rate was 60% or higher, with 51.9% of the patients reporting highest satisfaction scores Q-Switched 1064/532 nm laser may be considered today as the gold-standard treatment for tattoo removal. Our results confirm literature findings of the safety and effectiveness of these devices.