Cargando…
The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test
Composite materials are increasingly used to strengthen existing structures or new load-bearing elements, also made of timber. In this paper, the effect of the number of layers of Carbon Fiber Reinforced Polymer (CFRP) on the load-bearing capacity and stiffness of Glued Laminated Timber beams was de...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8304382/ https://www.ncbi.nlm.nih.gov/pubmed/34300938 http://dx.doi.org/10.3390/ma14144019 |
_version_ | 1783727321481478144 |
---|---|
author | Śliwa-Wieczorek, Klaudia Ostrowski, Krzysztof Adam Jaskowska-Lemańska, Justyna Karolak, Anna |
author_facet | Śliwa-Wieczorek, Klaudia Ostrowski, Krzysztof Adam Jaskowska-Lemańska, Justyna Karolak, Anna |
author_sort | Śliwa-Wieczorek, Klaudia |
collection | PubMed |
description | Composite materials are increasingly used to strengthen existing structures or new load-bearing elements, also made of timber. In this paper, the effect of the number of layers of Carbon Fiber Reinforced Polymer (CFRP) on the load-bearing capacity and stiffness of Glued Laminated Timber beams was determined. Experimental research was performed on 32 elements—a series of eight unreinforced beams, and three series of eight reinforced beams: with one, three and five layers of laminate each. The beams with a cross-section of 38 mm × 80 mm and a length of 750 mm were subjected to the four-point bending test according to standard procedure. For each series, destructive force, deflection, mode of failure, and equivalent stiffness were determined. In addition, for the selected samples, X-ray computed tomography was performed before and after their destruction to define the quality of the interface between wood and composite. The results of the conducted tests and analyses showed that there was no clear relationship between the number of reinforcement layers and the load-bearing capacity of the beams and their stiffness. Unreinforced beams failed due to tension, while reinforced CFRP beams failed due to shear. Despite this, a higher energy of failure of composite-reinforced elements was demonstrated in relation to the reference beams. |
format | Online Article Text |
id | pubmed-8304382 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83043822021-07-25 The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test Śliwa-Wieczorek, Klaudia Ostrowski, Krzysztof Adam Jaskowska-Lemańska, Justyna Karolak, Anna Materials (Basel) Article Composite materials are increasingly used to strengthen existing structures or new load-bearing elements, also made of timber. In this paper, the effect of the number of layers of Carbon Fiber Reinforced Polymer (CFRP) on the load-bearing capacity and stiffness of Glued Laminated Timber beams was determined. Experimental research was performed on 32 elements—a series of eight unreinforced beams, and three series of eight reinforced beams: with one, three and five layers of laminate each. The beams with a cross-section of 38 mm × 80 mm and a length of 750 mm were subjected to the four-point bending test according to standard procedure. For each series, destructive force, deflection, mode of failure, and equivalent stiffness were determined. In addition, for the selected samples, X-ray computed tomography was performed before and after their destruction to define the quality of the interface between wood and composite. The results of the conducted tests and analyses showed that there was no clear relationship between the number of reinforcement layers and the load-bearing capacity of the beams and their stiffness. Unreinforced beams failed due to tension, while reinforced CFRP beams failed due to shear. Despite this, a higher energy of failure of composite-reinforced elements was demonstrated in relation to the reference beams. MDPI 2021-07-18 /pmc/articles/PMC8304382/ /pubmed/34300938 http://dx.doi.org/10.3390/ma14144019 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Śliwa-Wieczorek, Klaudia Ostrowski, Krzysztof Adam Jaskowska-Lemańska, Justyna Karolak, Anna The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test |
title | The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test |
title_full | The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test |
title_fullStr | The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test |
title_full_unstemmed | The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test |
title_short | The Influence of CFRP Sheets on the Load-Bearing Capacity of the Glued Laminated Timber Beams under Bending Test |
title_sort | influence of cfrp sheets on the load-bearing capacity of the glued laminated timber beams under bending test |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8304382/ https://www.ncbi.nlm.nih.gov/pubmed/34300938 http://dx.doi.org/10.3390/ma14144019 |
work_keys_str_mv | AT sliwawieczorekklaudia theinfluenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest AT ostrowskikrzysztofadam theinfluenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest AT jaskowskalemanskajustyna theinfluenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest AT karolakanna theinfluenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest AT sliwawieczorekklaudia influenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest AT ostrowskikrzysztofadam influenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest AT jaskowskalemanskajustyna influenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest AT karolakanna influenceofcfrpsheetsontheloadbearingcapacityofthegluedlaminatedtimberbeamsunderbendingtest |