Cargando…
Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study
The method for the determination of primaquine (PQ) and 5,6-orthoquinone primaquine (5,6-PQ), the representative marker for PQ active metabolites, via CYP2D6 in human plasma and urine has been validated. All samples were extracted using acetonitrile for protein precipitation and analyzed using the u...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8304466/ https://www.ncbi.nlm.nih.gov/pubmed/34299634 http://dx.doi.org/10.3390/molecules26144357 |
_version_ | 1783727342746599424 |
---|---|
author | Pookmanee, Waritda Thongthip, Siriwan Tankanitlert, Jeeranut Mungthin, Mathirut Sukasem, Chonlaphat Wittayalertpanya, Supeecha |
author_facet | Pookmanee, Waritda Thongthip, Siriwan Tankanitlert, Jeeranut Mungthin, Mathirut Sukasem, Chonlaphat Wittayalertpanya, Supeecha |
author_sort | Pookmanee, Waritda |
collection | PubMed |
description | The method for the determination of primaquine (PQ) and 5,6-orthoquinone primaquine (5,6-PQ), the representative marker for PQ active metabolites, via CYP2D6 in human plasma and urine has been validated. All samples were extracted using acetonitrile for protein precipitation and analyzed using the ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) system. Chromatography separation was carried out using a Hypersil GOLD(TM) aQ C(18) column (100 × 2.1 mm, particle size 1.9 μm) with a C(18) guard column (4 × 3 mm) flowed with an isocratic mode of methanol, water, and acetonitrile in an optimal ratio at 0.4 mL/min. The retention times of 5,6-PQ and PQ in plasma and urine were 0.8 and 1.6 min, respectively. The method was validated according to the guideline. The linearity of the analytes was in the range of 25–1500 ng/mL. The matrix effect of PQ and 5,6-PQ ranged from 100% to 116% and from 87% to 104% for plasma, and from 87% to 89% and from 86% to 87% for urine, respectively. The recovery of PQ and 5,6-PQ ranged from 78% to 95% and form 80% to 98% for plasma, and from 102% to from 112% to 97% to 109% for urine, respectively. The accuracy and precision of PQ and 5,6-PQ in plasma and urine were within the acceptance criteria. The samples should be kept in the freezer (−80 °C) and analyzed within 7 days due to the metabolite stability. This validated UHPLC-MS/MS method was beneficial for a pharmacokinetic study in subjects receiving PQ. |
format | Online Article Text |
id | pubmed-8304466 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83044662021-07-25 Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study Pookmanee, Waritda Thongthip, Siriwan Tankanitlert, Jeeranut Mungthin, Mathirut Sukasem, Chonlaphat Wittayalertpanya, Supeecha Molecules Article The method for the determination of primaquine (PQ) and 5,6-orthoquinone primaquine (5,6-PQ), the representative marker for PQ active metabolites, via CYP2D6 in human plasma and urine has been validated. All samples were extracted using acetonitrile for protein precipitation and analyzed using the ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) system. Chromatography separation was carried out using a Hypersil GOLD(TM) aQ C(18) column (100 × 2.1 mm, particle size 1.9 μm) with a C(18) guard column (4 × 3 mm) flowed with an isocratic mode of methanol, water, and acetonitrile in an optimal ratio at 0.4 mL/min. The retention times of 5,6-PQ and PQ in plasma and urine were 0.8 and 1.6 min, respectively. The method was validated according to the guideline. The linearity of the analytes was in the range of 25–1500 ng/mL. The matrix effect of PQ and 5,6-PQ ranged from 100% to 116% and from 87% to 104% for plasma, and from 87% to 89% and from 86% to 87% for urine, respectively. The recovery of PQ and 5,6-PQ ranged from 78% to 95% and form 80% to 98% for plasma, and from 102% to from 112% to 97% to 109% for urine, respectively. The accuracy and precision of PQ and 5,6-PQ in plasma and urine were within the acceptance criteria. The samples should be kept in the freezer (−80 °C) and analyzed within 7 days due to the metabolite stability. This validated UHPLC-MS/MS method was beneficial for a pharmacokinetic study in subjects receiving PQ. MDPI 2021-07-19 /pmc/articles/PMC8304466/ /pubmed/34299634 http://dx.doi.org/10.3390/molecules26144357 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Pookmanee, Waritda Thongthip, Siriwan Tankanitlert, Jeeranut Mungthin, Mathirut Sukasem, Chonlaphat Wittayalertpanya, Supeecha Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study |
title | Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study |
title_full | Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study |
title_fullStr | Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study |
title_full_unstemmed | Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study |
title_short | Simplified and Rapid Determination of Primaquine and 5,6-Orthoquinone Primaquine by UHPLC-MS/MS: Its Application to a Pharmacokinetic Study |
title_sort | simplified and rapid determination of primaquine and 5,6-orthoquinone primaquine by uhplc-ms/ms: its application to a pharmacokinetic study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8304466/ https://www.ncbi.nlm.nih.gov/pubmed/34299634 http://dx.doi.org/10.3390/molecules26144357 |
work_keys_str_mv | AT pookmaneewaritda simplifiedandrapiddeterminationofprimaquineand56orthoquinoneprimaquinebyuhplcmsmsitsapplicationtoapharmacokineticstudy AT thongthipsiriwan simplifiedandrapiddeterminationofprimaquineand56orthoquinoneprimaquinebyuhplcmsmsitsapplicationtoapharmacokineticstudy AT tankanitlertjeeranut simplifiedandrapiddeterminationofprimaquineand56orthoquinoneprimaquinebyuhplcmsmsitsapplicationtoapharmacokineticstudy AT mungthinmathirut simplifiedandrapiddeterminationofprimaquineand56orthoquinoneprimaquinebyuhplcmsmsitsapplicationtoapharmacokineticstudy AT sukasemchonlaphat simplifiedandrapiddeterminationofprimaquineand56orthoquinoneprimaquinebyuhplcmsmsitsapplicationtoapharmacokineticstudy AT wittayalertpanyasupeecha simplifiedandrapiddeterminationofprimaquineand56orthoquinoneprimaquinebyuhplcmsmsitsapplicationtoapharmacokineticstudy |