Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use

(1) Background: In this study, we introduce a manufacturable 32-channel cochlear electrode array. In contrast to conventional cochlear electrode arrays manufactured by manual processes that consist of electrode-wire welding, the placement of each electrode, and silicone molding over wired structures...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Soowon, Ha, Yoonhee, Choi, Gwangjin, Hyun, Junewoo, Kim, Sangwoo, Oh, Seung-Ha, Min, Kyou-Sik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8304779/
https://www.ncbi.nlm.nih.gov/pubmed/34209329
http://dx.doi.org/10.3390/mi12070778
_version_ 1783727417049743360
author Shin, Soowon
Ha, Yoonhee
Choi, Gwangjin
Hyun, Junewoo
Kim, Sangwoo
Oh, Seung-Ha
Min, Kyou-Sik
author_facet Shin, Soowon
Ha, Yoonhee
Choi, Gwangjin
Hyun, Junewoo
Kim, Sangwoo
Oh, Seung-Ha
Min, Kyou-Sik
author_sort Shin, Soowon
collection PubMed
description (1) Background: In this study, we introduce a manufacturable 32-channel cochlear electrode array. In contrast to conventional cochlear electrode arrays manufactured by manual processes that consist of electrode-wire welding, the placement of each electrode, and silicone molding over wired structures, the proposed cochlear electrode array is manufactured by semi-automated laser micro-structuring and a mass-produced layer-by-layer silicone deposition scheme similar to the semiconductor fabrication process. (2) Methods: The proposed 32-channel electrode array has 32 electrode contacts with a length of 24 mm and 0.75 mm spacing between contacts. The width of the electrode array is 0.45 mm at its apex and 0.8 mm at its base, and it has a three-layered arrangement consisting of a 32-channel electrode layer and two 16-lead wire layers. To assess its feasibility, we conducted an electrochemical evaluation, stiffness measurements, and insertion force measurements. (3) Results: The electrochemical impedance and charge storage capacity are 3.11 ± 0.89 kOhm at 1 kHz and 5.09 mC/cm [Formula: see text] , respectively. The V/H ratio, which indicates how large the vertical stiffness is compared to the horizontal stiffness, is 1.26. The insertion force is 17.4 mN at 8 mm from the round window, and the maximum extraction force is 61.4 mN. (4) Conclusions: The results of the preliminary feasibility assessment of the proposed 32-channel cochlear electrode array are presented. After further assessments are performed, a 32-channel cochlear implant system consisting of the proposed 32-channel electrode array, 32-channel neural stimulation and recording IC, titanium-based hermetic package, and sound processor with wireless power and signal transmission coil will be completed.
format Online
Article
Text
id pubmed-8304779
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83047792021-07-25 Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use Shin, Soowon Ha, Yoonhee Choi, Gwangjin Hyun, Junewoo Kim, Sangwoo Oh, Seung-Ha Min, Kyou-Sik Micromachines (Basel) Article (1) Background: In this study, we introduce a manufacturable 32-channel cochlear electrode array. In contrast to conventional cochlear electrode arrays manufactured by manual processes that consist of electrode-wire welding, the placement of each electrode, and silicone molding over wired structures, the proposed cochlear electrode array is manufactured by semi-automated laser micro-structuring and a mass-produced layer-by-layer silicone deposition scheme similar to the semiconductor fabrication process. (2) Methods: The proposed 32-channel electrode array has 32 electrode contacts with a length of 24 mm and 0.75 mm spacing between contacts. The width of the electrode array is 0.45 mm at its apex and 0.8 mm at its base, and it has a three-layered arrangement consisting of a 32-channel electrode layer and two 16-lead wire layers. To assess its feasibility, we conducted an electrochemical evaluation, stiffness measurements, and insertion force measurements. (3) Results: The electrochemical impedance and charge storage capacity are 3.11 ± 0.89 kOhm at 1 kHz and 5.09 mC/cm [Formula: see text] , respectively. The V/H ratio, which indicates how large the vertical stiffness is compared to the horizontal stiffness, is 1.26. The insertion force is 17.4 mN at 8 mm from the round window, and the maximum extraction force is 61.4 mN. (4) Conclusions: The results of the preliminary feasibility assessment of the proposed 32-channel cochlear electrode array are presented. After further assessments are performed, a 32-channel cochlear implant system consisting of the proposed 32-channel electrode array, 32-channel neural stimulation and recording IC, titanium-based hermetic package, and sound processor with wireless power and signal transmission coil will be completed. MDPI 2021-06-30 /pmc/articles/PMC8304779/ /pubmed/34209329 http://dx.doi.org/10.3390/mi12070778 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shin, Soowon
Ha, Yoonhee
Choi, Gwangjin
Hyun, Junewoo
Kim, Sangwoo
Oh, Seung-Ha
Min, Kyou-Sik
Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use
title Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use
title_full Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use
title_fullStr Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use
title_full_unstemmed Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use
title_short Manufacturable 32-Channel Cochlear Electrode Array and Preliminary Assessment of Its Feasibility for Clinical Use
title_sort manufacturable 32-channel cochlear electrode array and preliminary assessment of its feasibility for clinical use
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8304779/
https://www.ncbi.nlm.nih.gov/pubmed/34209329
http://dx.doi.org/10.3390/mi12070778
work_keys_str_mv AT shinsoowon manufacturable32channelcochlearelectrodearrayandpreliminaryassessmentofitsfeasibilityforclinicaluse
AT hayoonhee manufacturable32channelcochlearelectrodearrayandpreliminaryassessmentofitsfeasibilityforclinicaluse
AT choigwangjin manufacturable32channelcochlearelectrodearrayandpreliminaryassessmentofitsfeasibilityforclinicaluse
AT hyunjunewoo manufacturable32channelcochlearelectrodearrayandpreliminaryassessmentofitsfeasibilityforclinicaluse
AT kimsangwoo manufacturable32channelcochlearelectrodearrayandpreliminaryassessmentofitsfeasibilityforclinicaluse
AT ohseungha manufacturable32channelcochlearelectrodearrayandpreliminaryassessmentofitsfeasibilityforclinicaluse
AT minkyousik manufacturable32channelcochlearelectrodearrayandpreliminaryassessmentofitsfeasibilityforclinicaluse