Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function

Biological barriers are essential for the maintenance of organ homeostasis and their dysfunction is responsible for many prevalent diseases. Advanced in vitro models of biological barriers have been developed through the combination of 3D cell culture techniques and organ-on-chip (OoC) technology. H...

Descripción completa

Detalles Bibliográficos
Autores principales: Zoio, Patrícia, Lopes-Ventura, Sara, Oliva, Abel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8305171/
https://www.ncbi.nlm.nih.gov/pubmed/34357226
http://dx.doi.org/10.3390/mi12070816
_version_ 1783727510405513216
author Zoio, Patrícia
Lopes-Ventura, Sara
Oliva, Abel
author_facet Zoio, Patrícia
Lopes-Ventura, Sara
Oliva, Abel
author_sort Zoio, Patrícia
collection PubMed
description Biological barriers are essential for the maintenance of organ homeostasis and their dysfunction is responsible for many prevalent diseases. Advanced in vitro models of biological barriers have been developed through the combination of 3D cell culture techniques and organ-on-chip (OoC) technology. However, real-time monitoring of tissue function inside the OoC devices has been challenging, with most approaches relying on off-chip analysis and imaging techniques. In this study, we designed and fabricated a low-cost barrier-on-chip (BoC) device with integrated electrodes for the development and real-time monitoring of biological barriers. The integrated electrodes were used to measure transepithelial electrical resistance (TEER) during tissue culture, thereby quantitatively evaluating tissue barrier function. A finite element analysis was performed to study the sensitivity of the integrated electrodes and to compare them with conventional systems. As proof-of-concept, a full-thickness human skin model (FTSm) was grown on the developed BoC, and TEER was measured on-chip during the culture. After 14 days of culture, the barrier tissue was challenged with a benchmark irritant and its impact was evaluated on-chip through TEER measurements. The developed BoC with an integrated sensing capability represents a promising tool for real-time assessment of barrier function in the context of drug testing and disease modelling.
format Online
Article
Text
id pubmed-8305171
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83051712021-07-25 Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function Zoio, Patrícia Lopes-Ventura, Sara Oliva, Abel Micromachines (Basel) Article Biological barriers are essential for the maintenance of organ homeostasis and their dysfunction is responsible for many prevalent diseases. Advanced in vitro models of biological barriers have been developed through the combination of 3D cell culture techniques and organ-on-chip (OoC) technology. However, real-time monitoring of tissue function inside the OoC devices has been challenging, with most approaches relying on off-chip analysis and imaging techniques. In this study, we designed and fabricated a low-cost barrier-on-chip (BoC) device with integrated electrodes for the development and real-time monitoring of biological barriers. The integrated electrodes were used to measure transepithelial electrical resistance (TEER) during tissue culture, thereby quantitatively evaluating tissue barrier function. A finite element analysis was performed to study the sensitivity of the integrated electrodes and to compare them with conventional systems. As proof-of-concept, a full-thickness human skin model (FTSm) was grown on the developed BoC, and TEER was measured on-chip during the culture. After 14 days of culture, the barrier tissue was challenged with a benchmark irritant and its impact was evaluated on-chip through TEER measurements. The developed BoC with an integrated sensing capability represents a promising tool for real-time assessment of barrier function in the context of drug testing and disease modelling. MDPI 2021-07-12 /pmc/articles/PMC8305171/ /pubmed/34357226 http://dx.doi.org/10.3390/mi12070816 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zoio, Patrícia
Lopes-Ventura, Sara
Oliva, Abel
Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function
title Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function
title_full Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function
title_fullStr Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function
title_full_unstemmed Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function
title_short Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function
title_sort barrier-on-a-chip with a modular architecture and integrated sensors for real-time measurement of biological barrier function
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8305171/
https://www.ncbi.nlm.nih.gov/pubmed/34357226
http://dx.doi.org/10.3390/mi12070816
work_keys_str_mv AT zoiopatricia barrieronachipwithamodulararchitectureandintegratedsensorsforrealtimemeasurementofbiologicalbarrierfunction
AT lopesventurasara barrieronachipwithamodulararchitectureandintegratedsensorsforrealtimemeasurementofbiologicalbarrierfunction
AT olivaabel barrieronachipwithamodulararchitectureandintegratedsensorsforrealtimemeasurementofbiologicalbarrierfunction