Cargando…

Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater

Monitoring and quantification of active pharmaceutical ingredients (APIs) in the environment constitute important and challenging tasks, as they are directly associated with human health. Three commonly used proton pump inhibitors (PPIs), namely, omeprazole sodium (OMP), pantoprazole sodium (PNT), a...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdel-Gawad, Sherif A., Arab, Hany H., Alabbas, Alhumaidi B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8306645/
https://www.ncbi.nlm.nih.gov/pubmed/34299632
http://dx.doi.org/10.3390/molecules26144358
_version_ 1783727860250312704
author Abdel-Gawad, Sherif A.
Arab, Hany H.
Alabbas, Alhumaidi B.
author_facet Abdel-Gawad, Sherif A.
Arab, Hany H.
Alabbas, Alhumaidi B.
author_sort Abdel-Gawad, Sherif A.
collection PubMed
description Monitoring and quantification of active pharmaceutical ingredients (APIs) in the environment constitute important and challenging tasks, as they are directly associated with human health. Three commonly used proton pump inhibitors (PPIs), namely, omeprazole sodium (OMP), pantoprazole sodium (PNT), and lansoprazole sodium (LNZ) are well separated and quantified using ultra-performance liquid chromatography (UPLC) in pharmaceutical industrial wastewater. The separation of the studied drugs was performed on a stationary phase with a Waters(TM) column (100 × 2.1 mm, 1.7 µm). The mobile phase was composed of methanol:0.05 M potassium dihydrogen phosphate buffer (adjusted to pH 7.5 using NaOH) (50:50, v/v). The elution process was done in gradient mode by changing the relative proportions of the mobile phase components with time to get an optimum separation pattern. The flow rate of the developing system was adjusted to 0.8 mL/minute. Detection of the separated drugs was performed at 230 nm. The studied drugs were quantified in the concentration range of 10–200 ng/mL for all drugs. The cited method was fully validated according to the international conference on harmonization (ICH-Q2B) guidelines, then it was applied successfully for quantification of the studied PPIs in real wastewater samples after their solid phase extraction (SPE).
format Online
Article
Text
id pubmed-8306645
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83066452021-07-25 Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater Abdel-Gawad, Sherif A. Arab, Hany H. Alabbas, Alhumaidi B. Molecules Article Monitoring and quantification of active pharmaceutical ingredients (APIs) in the environment constitute important and challenging tasks, as they are directly associated with human health. Three commonly used proton pump inhibitors (PPIs), namely, omeprazole sodium (OMP), pantoprazole sodium (PNT), and lansoprazole sodium (LNZ) are well separated and quantified using ultra-performance liquid chromatography (UPLC) in pharmaceutical industrial wastewater. The separation of the studied drugs was performed on a stationary phase with a Waters(TM) column (100 × 2.1 mm, 1.7 µm). The mobile phase was composed of methanol:0.05 M potassium dihydrogen phosphate buffer (adjusted to pH 7.5 using NaOH) (50:50, v/v). The elution process was done in gradient mode by changing the relative proportions of the mobile phase components with time to get an optimum separation pattern. The flow rate of the developing system was adjusted to 0.8 mL/minute. Detection of the separated drugs was performed at 230 nm. The studied drugs were quantified in the concentration range of 10–200 ng/mL for all drugs. The cited method was fully validated according to the international conference on harmonization (ICH-Q2B) guidelines, then it was applied successfully for quantification of the studied PPIs in real wastewater samples after their solid phase extraction (SPE). MDPI 2021-07-19 /pmc/articles/PMC8306645/ /pubmed/34299632 http://dx.doi.org/10.3390/molecules26144358 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abdel-Gawad, Sherif A.
Arab, Hany H.
Alabbas, Alhumaidi B.
Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater
title Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater
title_full Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater
title_fullStr Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater
title_full_unstemmed Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater
title_short Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater
title_sort validated simultaneous gradient ultra-performance liquid chromatographic quantification of some proton pump inhibitor drug residues in saudi pharmaceutical industrial wastewater
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8306645/
https://www.ncbi.nlm.nih.gov/pubmed/34299632
http://dx.doi.org/10.3390/molecules26144358
work_keys_str_mv AT abdelgawadsherifa validatedsimultaneousgradientultraperformanceliquidchromatographicquantificationofsomeprotonpumpinhibitordrugresiduesinsaudipharmaceuticalindustrialwastewater
AT arabhanyh validatedsimultaneousgradientultraperformanceliquidchromatographicquantificationofsomeprotonpumpinhibitordrugresiduesinsaudipharmaceuticalindustrialwastewater
AT alabbasalhumaidib validatedsimultaneousgradientultraperformanceliquidchromatographicquantificationofsomeprotonpumpinhibitordrugresiduesinsaudipharmaceuticalindustrialwastewater