Cargando…

Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) is recommended for type B aortic dissection and recently has even been used in selected cases of proximal (Stanford type A) aortic dissections in scenarios of prohibitive surgical risk. However, mechanical interactions between the native aorta a...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Xun, Kan, Xiaoxin, Xu, Xiao Yun, Nienaber, Christoph A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8307501/
https://www.ncbi.nlm.nih.gov/pubmed/34317961
http://dx.doi.org/10.1016/j.xjtc.2020.10.006
_version_ 1783728064517111808
author Yuan, Xun
Kan, Xiaoxin
Xu, Xiao Yun
Nienaber, Christoph A.
author_facet Yuan, Xun
Kan, Xiaoxin
Xu, Xiao Yun
Nienaber, Christoph A.
author_sort Yuan, Xun
collection PubMed
description OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) is recommended for type B aortic dissection and recently has even been used in selected cases of proximal (Stanford type A) aortic dissections in scenarios of prohibitive surgical risk. However, mechanical interactions between the native aorta and stent-graft are poorly understood, as some cases ended in failure. The aim of this study is to explore and better understand biomechanical changes after TEVAR and predict the result via virtual stenting. METHODS: A case of type A aortic dissection was considered inoperable and selected for TEVAR. The procedure failed due to stent-graft migration even with precise deployment. A novel patient-specific virtual stent-graft deployment model based on finite element method was employed to analyze TEVAR-induced changes under such conditions. Two landing positions were simulated to investigate the reason for stent-graft migration immediately after TEVAR and explore options for optimization. RESULTS: Simulation of the actual procedure revealed that the proximal bare metal stent pushed the lamella into the false lumen and led to further stent-graft migration during the launch phase. An alternative landing position has reduced the local deformation of the dissection lamella and avoided stent-graft migration. Higher maximum principal stress (>20 KPa) was found on the lamella with deployment at the actual position, while the alternative strategy would have reduced the stress to <5 KPa. CONCLUSIONS: Virtual stent-graft deployment simulation based on finite element model could be helpful to both predict outcomes of TEVAR and better plan future endovascular procedures.
format Online
Article
Text
id pubmed-8307501
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83075012021-07-26 Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection Yuan, Xun Kan, Xiaoxin Xu, Xiao Yun Nienaber, Christoph A. JTCVS Tech Adult: Aorta OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) is recommended for type B aortic dissection and recently has even been used in selected cases of proximal (Stanford type A) aortic dissections in scenarios of prohibitive surgical risk. However, mechanical interactions between the native aorta and stent-graft are poorly understood, as some cases ended in failure. The aim of this study is to explore and better understand biomechanical changes after TEVAR and predict the result via virtual stenting. METHODS: A case of type A aortic dissection was considered inoperable and selected for TEVAR. The procedure failed due to stent-graft migration even with precise deployment. A novel patient-specific virtual stent-graft deployment model based on finite element method was employed to analyze TEVAR-induced changes under such conditions. Two landing positions were simulated to investigate the reason for stent-graft migration immediately after TEVAR and explore options for optimization. RESULTS: Simulation of the actual procedure revealed that the proximal bare metal stent pushed the lamella into the false lumen and led to further stent-graft migration during the launch phase. An alternative landing position has reduced the local deformation of the dissection lamella and avoided stent-graft migration. Higher maximum principal stress (>20 KPa) was found on the lamella with deployment at the actual position, while the alternative strategy would have reduced the stress to <5 KPa. CONCLUSIONS: Virtual stent-graft deployment simulation based on finite element model could be helpful to both predict outcomes of TEVAR and better plan future endovascular procedures. Elsevier 2020-10-13 /pmc/articles/PMC8307501/ /pubmed/34317961 http://dx.doi.org/10.1016/j.xjtc.2020.10.006 Text en © 2020 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Adult: Aorta
Yuan, Xun
Kan, Xiaoxin
Xu, Xiao Yun
Nienaber, Christoph A.
Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection
title Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection
title_full Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection
title_fullStr Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection
title_full_unstemmed Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection
title_short Finite element modeling to predict procedural success of thoracic endovascular aortic repair in type A aortic dissection
title_sort finite element modeling to predict procedural success of thoracic endovascular aortic repair in type a aortic dissection
topic Adult: Aorta
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8307501/
https://www.ncbi.nlm.nih.gov/pubmed/34317961
http://dx.doi.org/10.1016/j.xjtc.2020.10.006
work_keys_str_mv AT yuanxun finiteelementmodelingtopredictproceduralsuccessofthoracicendovascularaorticrepairintypeaaorticdissection
AT kanxiaoxin finiteelementmodelingtopredictproceduralsuccessofthoracicendovascularaorticrepairintypeaaorticdissection
AT xuxiaoyun finiteelementmodelingtopredictproceduralsuccessofthoracicendovascularaorticrepairintypeaaorticdissection
AT nienaberchristopha finiteelementmodelingtopredictproceduralsuccessofthoracicendovascularaorticrepairintypeaaorticdissection