Cargando…
Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors
Robust conductive hydrogels are in great demand for the practical applications of smart soft robots, epidermal electronics, and human–machine interactions. We successfully prepared nanoparticles enhanced polyacrylamide/hydroxypropyl guar gum/acryloyl-grafted chitosan quaternary ammonium salt/calcium...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8308457/ https://www.ncbi.nlm.nih.gov/pubmed/34361240 http://dx.doi.org/10.3390/nano11071854 |
_version_ | 1783728285748822016 |
---|---|
author | Xu, Xiuru He, Chubin Luo, Feng Wang, Hao Peng, Zhengchun |
author_facet | Xu, Xiuru He, Chubin Luo, Feng Wang, Hao Peng, Zhengchun |
author_sort | Xu, Xiuru |
collection | PubMed |
description | Robust conductive hydrogels are in great demand for the practical applications of smart soft robots, epidermal electronics, and human–machine interactions. We successfully prepared nanoparticles enhanced polyacrylamide/hydroxypropyl guar gum/acryloyl-grafted chitosan quaternary ammonium salt/calcium ions/SiO(2) nanoparticles (PHC/Ca(2+)/SiO(2) NPs) conductive hydrogels. Owing to the stable chemical and physical hybrid crosslinking networks and reversible non-covalent interactions, the PHC/Ca(2+)/SiO(2) NPs conductive hydrogel showed good conductivity (~3.39 S/m), excellent toughness (6.71 MJ/m(3)), high stretchability (2256%), fast self-recovery (80% within 10 s, and 100% within 30 s), and good fatigue resistance. The maximum gauge factor as high as 66.99 was obtained, with a wide detectable strain range (from 0.25% to 500% strain), the fast response (25.00 ms) and recovery time (86.12 ms), excellent negligible response hysteresis, and good response stability. The applications of monitoring the human’s body movements were demonstrated, such as wrist bending and pulse tracking. |
format | Online Article Text |
id | pubmed-8308457 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83084572021-07-25 Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors Xu, Xiuru He, Chubin Luo, Feng Wang, Hao Peng, Zhengchun Nanomaterials (Basel) Article Robust conductive hydrogels are in great demand for the practical applications of smart soft robots, epidermal electronics, and human–machine interactions. We successfully prepared nanoparticles enhanced polyacrylamide/hydroxypropyl guar gum/acryloyl-grafted chitosan quaternary ammonium salt/calcium ions/SiO(2) nanoparticles (PHC/Ca(2+)/SiO(2) NPs) conductive hydrogels. Owing to the stable chemical and physical hybrid crosslinking networks and reversible non-covalent interactions, the PHC/Ca(2+)/SiO(2) NPs conductive hydrogel showed good conductivity (~3.39 S/m), excellent toughness (6.71 MJ/m(3)), high stretchability (2256%), fast self-recovery (80% within 10 s, and 100% within 30 s), and good fatigue resistance. The maximum gauge factor as high as 66.99 was obtained, with a wide detectable strain range (from 0.25% to 500% strain), the fast response (25.00 ms) and recovery time (86.12 ms), excellent negligible response hysteresis, and good response stability. The applications of monitoring the human’s body movements were demonstrated, such as wrist bending and pulse tracking. MDPI 2021-07-19 /pmc/articles/PMC8308457/ /pubmed/34361240 http://dx.doi.org/10.3390/nano11071854 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xu, Xiuru He, Chubin Luo, Feng Wang, Hao Peng, Zhengchun Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors |
title | Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors |
title_full | Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors |
title_fullStr | Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors |
title_full_unstemmed | Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors |
title_short | Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors |
title_sort | robust conductive hydrogels with ultrafast self-recovery and nearly zero response hysteresis for epidermal sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8308457/ https://www.ncbi.nlm.nih.gov/pubmed/34361240 http://dx.doi.org/10.3390/nano11071854 |
work_keys_str_mv | AT xuxiuru robustconductivehydrogelswithultrafastselfrecoveryandnearlyzeroresponsehysteresisforepidermalsensors AT hechubin robustconductivehydrogelswithultrafastselfrecoveryandnearlyzeroresponsehysteresisforepidermalsensors AT luofeng robustconductivehydrogelswithultrafastselfrecoveryandnearlyzeroresponsehysteresisforepidermalsensors AT wanghao robustconductivehydrogelswithultrafastselfrecoveryandnearlyzeroresponsehysteresisforepidermalsensors AT pengzhengchun robustconductivehydrogelswithultrafastselfrecoveryandnearlyzeroresponsehysteresisforepidermalsensors |