Cargando…

Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics

Many pharmaceutics are aqueous dispersions of small or large molecules, often self-assembled in complexes from a few to hundreds of molecules. In many cases, the dispersing liquid is non-aqueous. Many pharmaceutical preparations are very viscous. The efficacy of those dispersions is in many cases a...

Descripción completa

Detalles Bibliográficos
Autores principales: Koifman, Na’ama, Talmon, Yeshayahu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8308931/
https://www.ncbi.nlm.nih.gov/pubmed/34371706
http://dx.doi.org/10.3390/pharmaceutics13071015
_version_ 1783728401028218880
author Koifman, Na’ama
Talmon, Yeshayahu
author_facet Koifman, Na’ama
Talmon, Yeshayahu
author_sort Koifman, Na’ama
collection PubMed
description Many pharmaceutics are aqueous dispersions of small or large molecules, often self-assembled in complexes from a few to hundreds of molecules. In many cases, the dispersing liquid is non-aqueous. Many pharmaceutical preparations are very viscous. The efficacy of those dispersions is in many cases a function of the nanostructure of those complexes or aggregates. To study the nanostructure of those systems, one needs electron microscopy, the only way to obtain nanostructural information by recording direct images whose interpretation is not model-dependent. However, these methodologies are complicated by the need to make liquid systems compatible with high vacuum in electron microscopes. There are also issues related to the interaction of the electron beam with the specimen such as micrograph contrast, electron beam radiation damage, and artifacts associated with specimen preparation. In this article, which is focused on the state of the art of imaging self-assembled complexes, we briefly describe cryogenic temperature transmission electron microscopy (cryo-TEM) and cryogenic temperature scanning electron microcopy (cryo-SEM). We present the principles of these methodologies, give examples of their applications as analytical tools for pharmaceutics, and list their limitations and ways to avoid pitfalls in their application.
format Online
Article
Text
id pubmed-8308931
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83089312021-07-25 Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics Koifman, Na’ama Talmon, Yeshayahu Pharmaceutics Review Many pharmaceutics are aqueous dispersions of small or large molecules, often self-assembled in complexes from a few to hundreds of molecules. In many cases, the dispersing liquid is non-aqueous. Many pharmaceutical preparations are very viscous. The efficacy of those dispersions is in many cases a function of the nanostructure of those complexes or aggregates. To study the nanostructure of those systems, one needs electron microscopy, the only way to obtain nanostructural information by recording direct images whose interpretation is not model-dependent. However, these methodologies are complicated by the need to make liquid systems compatible with high vacuum in electron microscopes. There are also issues related to the interaction of the electron beam with the specimen such as micrograph contrast, electron beam radiation damage, and artifacts associated with specimen preparation. In this article, which is focused on the state of the art of imaging self-assembled complexes, we briefly describe cryogenic temperature transmission electron microscopy (cryo-TEM) and cryogenic temperature scanning electron microcopy (cryo-SEM). We present the principles of these methodologies, give examples of their applications as analytical tools for pharmaceutics, and list their limitations and ways to avoid pitfalls in their application. MDPI 2021-07-02 /pmc/articles/PMC8308931/ /pubmed/34371706 http://dx.doi.org/10.3390/pharmaceutics13071015 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Koifman, Na’ama
Talmon, Yeshayahu
Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics
title Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics
title_full Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics
title_fullStr Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics
title_full_unstemmed Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics
title_short Cryogenic Electron Microscopy Methodologies as Analytical Tools for the Study of Self-Assembled Pharmaceutics
title_sort cryogenic electron microscopy methodologies as analytical tools for the study of self-assembled pharmaceutics
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8308931/
https://www.ncbi.nlm.nih.gov/pubmed/34371706
http://dx.doi.org/10.3390/pharmaceutics13071015
work_keys_str_mv AT koifmannaama cryogenicelectronmicroscopymethodologiesasanalyticaltoolsforthestudyofselfassembledpharmaceutics
AT talmonyeshayahu cryogenicelectronmicroscopymethodologiesasanalyticaltoolsforthestudyofselfassembledpharmaceutics