Cargando…

Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests

This work analyzes the difference in stiffness in a steel laboratory structure using clamped joints or bolted joints and analyzes if the stiffness varies in the same way when the frame is subjected to external dynamic loads that bring the joint materials to their yield strength. To make this compari...

Descripción completa

Detalles Bibliográficos
Autores principales: Cabaleiro, Manuel, Moutinho, Carlos, González-Gaya, Cristina, Caetano, Elsa, Rosales-Prieto, Victor Fco.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8309884/
https://www.ncbi.nlm.nih.gov/pubmed/34300523
http://dx.doi.org/10.3390/s21144778
_version_ 1783728628082671616
author Cabaleiro, Manuel
Moutinho, Carlos
González-Gaya, Cristina
Caetano, Elsa
Rosales-Prieto, Victor Fco.
author_facet Cabaleiro, Manuel
Moutinho, Carlos
González-Gaya, Cristina
Caetano, Elsa
Rosales-Prieto, Victor Fco.
author_sort Cabaleiro, Manuel
collection PubMed
description This work analyzes the difference in stiffness in a steel laboratory structure using clamped joints or bolted joints and analyzes if the stiffness varies in the same way when the frame is subjected to external dynamic loads that bring the joint materials to their yield strength. To make this comparison, the differences between clamp joint and bolted joint were evaluated using a novel methodology based on the analysis of the structure’s natural frequencies from accelerometers. To perform this comparison, several laboratory tests were carried out on a frame made by clamped joints and the same frame made by bolted joints, using a set of tests on a medium-scale shake table for this purpose. The results achieved have verified the methodology used as adequate.
format Online
Article
Text
id pubmed-8309884
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83098842021-07-25 Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests Cabaleiro, Manuel Moutinho, Carlos González-Gaya, Cristina Caetano, Elsa Rosales-Prieto, Victor Fco. Sensors (Basel) Article This work analyzes the difference in stiffness in a steel laboratory structure using clamped joints or bolted joints and analyzes if the stiffness varies in the same way when the frame is subjected to external dynamic loads that bring the joint materials to their yield strength. To make this comparison, the differences between clamp joint and bolted joint were evaluated using a novel methodology based on the analysis of the structure’s natural frequencies from accelerometers. To perform this comparison, several laboratory tests were carried out on a frame made by clamped joints and the same frame made by bolted joints, using a set of tests on a medium-scale shake table for this purpose. The results achieved have verified the methodology used as adequate. MDPI 2021-07-13 /pmc/articles/PMC8309884/ /pubmed/34300523 http://dx.doi.org/10.3390/s21144778 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cabaleiro, Manuel
Moutinho, Carlos
González-Gaya, Cristina
Caetano, Elsa
Rosales-Prieto, Victor Fco.
Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests
title Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests
title_full Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests
title_fullStr Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests
title_full_unstemmed Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests
title_short Analysis of Stiffness of Clamped Joints versus Bolted Joints in Steel Structures by Means of Accelerometers and Shaking Table Tests
title_sort analysis of stiffness of clamped joints versus bolted joints in steel structures by means of accelerometers and shaking table tests
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8309884/
https://www.ncbi.nlm.nih.gov/pubmed/34300523
http://dx.doi.org/10.3390/s21144778
work_keys_str_mv AT cabaleiromanuel analysisofstiffnessofclampedjointsversusboltedjointsinsteelstructuresbymeansofaccelerometersandshakingtabletests
AT moutinhocarlos analysisofstiffnessofclampedjointsversusboltedjointsinsteelstructuresbymeansofaccelerometersandshakingtabletests
AT gonzalezgayacristina analysisofstiffnessofclampedjointsversusboltedjointsinsteelstructuresbymeansofaccelerometersandshakingtabletests
AT caetanoelsa analysisofstiffnessofclampedjointsversusboltedjointsinsteelstructuresbymeansofaccelerometersandshakingtabletests
AT rosalesprietovictorfco analysisofstiffnessofclampedjointsversusboltedjointsinsteelstructuresbymeansofaccelerometersandshakingtabletests