Preemptive Alcohol Septal Ablation Prior to Valve-in-Valve Transcatheter Mitral Valve Replacement With Bioprosthetic Balloon Fracture
A 78-year-old woman with bioprosthetic mitral valve degeneration at high risk for reoperation was referred for transcatheter mitral valve replacement. We describe the use of a preemptive alcohol septal ablation pre-procedurally to minimize the risk of acute left ventricular outflow tract obstruction...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8311042/ https://www.ncbi.nlm.nih.gov/pubmed/34317538 http://dx.doi.org/10.1016/j.jaccas.2020.12.021 |
Sumario: | A 78-year-old woman with bioprosthetic mitral valve degeneration at high risk for reoperation was referred for transcatheter mitral valve replacement. We describe the use of a preemptive alcohol septal ablation pre-procedurally to minimize the risk of acute left ventricular outflow tract obstruction given the anticipated need for a bioprosthetic valve fracture. (Level of Difficulty: Advanced.) |
---|