Cargando…
Ventricular Fibrillation Due to Aortocoronary Vein Graft Spasm During Angiography: Case Report and Literature Review
A 69-year-old man underwent coronary angiography 7 years after coronary artery bypass. Saphenous vein graft spasm was observed during contrast injection, resulting in ventricular fibrillation. Angiography 6 years later showed graft patency. Vein graft spasm after coronary artery bypass grafting is r...
Autores principales: | Arps, Kelly, Chakravartti, Jaidip, Hess, Connie N., Rao, Sunil V. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8311046/ https://www.ncbi.nlm.nih.gov/pubmed/34317543 http://dx.doi.org/10.1016/j.jaccas.2020.12.044 |
Ejemplares similares
-
Repurposing Riociguat for Treatment of Refractory Angina Resulting From Coronary Spasm
por: Martínez Pereyra, Valeria, et al.
Publicado: (2021) -
Single-Session Thrombolysis-Free Treatment of Deep Vein Thrombosis With a Novel Mechanical Thrombectomy Device
por: Raskin, Adam, et al.
Publicado: (2021) -
Percutaneous Ventricular Assist Device Fracture in the Right Ventricle and its Retrieval
por: Alhasan, Faysal, et al.
Publicado: (2022) -
Mechanical Non-ST-Segment Elevation Myocardial Infarction Secondary to Left Ventricular Outflow Tract Pseudoaneurysm: A Unique Entity
por: Kumar, Jathinder, et al.
Publicado: (2022) -
Management of Iatrogenic Coronary Artery Dissections: Failing to Prepare Is Preparing to Fail
por: Fischman, David L., et al.
Publicado: (2021)