Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan
BACKGROUND: In children, stainless steel crowns (SSCs) have become an invaluable restorative option for grossly decayed primary teeth. The crowns are manufactured in different sizes with preformed anatomy which requires trimming or contouring as a necessary step to fit an individual tooth. Initially...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Jaypee Brothers Medical Publishers
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8311754/ https://www.ncbi.nlm.nih.gov/pubmed/34326583 http://dx.doi.org/10.5005/jp-journals-10005-1900 |
_version_ | 1783729022288527360 |
---|---|
author | Aishwarya, Nanjappa Nagarathna, Chikkanarasaiah Poovani, Shwetha Thumati, Prafulla |
author_facet | Aishwarya, Nanjappa Nagarathna, Chikkanarasaiah Poovani, Shwetha Thumati, Prafulla |
author_sort | Aishwarya, Nanjappa |
collection | PubMed |
description | BACKGROUND: In children, stainless steel crowns (SSCs) have become an invaluable restorative option for grossly decayed primary teeth. The crowns are manufactured in different sizes with preformed anatomy which requires trimming or contouring as a necessary step to fit an individual tooth. Initially, this may produce variation in the occlusal contact points yet may not result in pain or discomfort. Little research exists regarding bite force equilibration measurements in children after placing SSC, and its influencing factors such as age and gender. AIM AND OBJECTIVE: To evaluate and compare the measurements of bite force pre- and post-cementation of SSC using the conventional technique at maximal intercuspal position (MIP) on primary molars at different time intervals and whether age and gender influence bite force measurements. DESIGN: Bite force and occlusal contacts during occlusion were made using T-Scan III. Twenty children scheduled for treatment who needed SSCs were included. T-Scan measurements of the bite force and occlusal contacts of the maxilla and mandibular teeth were recorded and analyzed before and immediately after cementation of SSC later 4 weeks during the follow-up period. These measurements were correlated with age and gender influence. RESULTS: There was no significant result in the percentage of bite force on the crowned tooth (placement of SSC) at different time intervals. Prematurities were present in all the groups but a significant reduction was seen on the crowned tooth from baseline to 1-month follow-up (p = 0.03). Also, a statistically significant increase in the bite force was seen in >7 years of age (p = 0.006) and no statistical significance among the gender. CONCLUSION: Following the standard tooth preparation, the SSC will continue to appear clinically acceptable for many years. Our study children showed an adaptable masticatory system irrespective of age and gender during growth and development. HOW TO CITE THIS ARTICLE: Aishwarya N, Nagarathna C, Poovani S, et al. Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan. Int J Clin Pediatr Dent 2021;14(1):46–50. |
format | Online Article Text |
id | pubmed-8311754 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Jaypee Brothers Medical Publishers |
record_format | MEDLINE/PubMed |
spelling | pubmed-83117542021-07-28 Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan Aishwarya, Nanjappa Nagarathna, Chikkanarasaiah Poovani, Shwetha Thumati, Prafulla Int J Clin Pediatr Dent Research Article BACKGROUND: In children, stainless steel crowns (SSCs) have become an invaluable restorative option for grossly decayed primary teeth. The crowns are manufactured in different sizes with preformed anatomy which requires trimming or contouring as a necessary step to fit an individual tooth. Initially, this may produce variation in the occlusal contact points yet may not result in pain or discomfort. Little research exists regarding bite force equilibration measurements in children after placing SSC, and its influencing factors such as age and gender. AIM AND OBJECTIVE: To evaluate and compare the measurements of bite force pre- and post-cementation of SSC using the conventional technique at maximal intercuspal position (MIP) on primary molars at different time intervals and whether age and gender influence bite force measurements. DESIGN: Bite force and occlusal contacts during occlusion were made using T-Scan III. Twenty children scheduled for treatment who needed SSCs were included. T-Scan measurements of the bite force and occlusal contacts of the maxilla and mandibular teeth were recorded and analyzed before and immediately after cementation of SSC later 4 weeks during the follow-up period. These measurements were correlated with age and gender influence. RESULTS: There was no significant result in the percentage of bite force on the crowned tooth (placement of SSC) at different time intervals. Prematurities were present in all the groups but a significant reduction was seen on the crowned tooth from baseline to 1-month follow-up (p = 0.03). Also, a statistically significant increase in the bite force was seen in >7 years of age (p = 0.006) and no statistical significance among the gender. CONCLUSION: Following the standard tooth preparation, the SSC will continue to appear clinically acceptable for many years. Our study children showed an adaptable masticatory system irrespective of age and gender during growth and development. HOW TO CITE THIS ARTICLE: Aishwarya N, Nagarathna C, Poovani S, et al. Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan. Int J Clin Pediatr Dent 2021;14(1):46–50. Jaypee Brothers Medical Publishers 2021 /pmc/articles/PMC8311754/ /pubmed/34326583 http://dx.doi.org/10.5005/jp-journals-10005-1900 Text en Copyright © 2021; Jaypee Brothers Medical Publishers (P) Ltd. https://creativecommons.org/licenses/by-nc/4.0/© Jaypee Brothers Medical Publishers. 2021 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Aishwarya, Nanjappa Nagarathna, Chikkanarasaiah Poovani, Shwetha Thumati, Prafulla Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan |
title | Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan |
title_full | Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan |
title_fullStr | Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan |
title_full_unstemmed | Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan |
title_short | Comparison of Bite Force and the Influencing Factors Pre- and Post-cementation of Stainless Steel Crown in Children Using T-Scan |
title_sort | comparison of bite force and the influencing factors pre- and post-cementation of stainless steel crown in children using t-scan |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8311754/ https://www.ncbi.nlm.nih.gov/pubmed/34326583 http://dx.doi.org/10.5005/jp-journals-10005-1900 |
work_keys_str_mv | AT aishwaryananjappa comparisonofbiteforceandtheinfluencingfactorspreandpostcementationofstainlesssteelcrowninchildrenusingtscan AT nagarathnachikkanarasaiah comparisonofbiteforceandtheinfluencingfactorspreandpostcementationofstainlesssteelcrowninchildrenusingtscan AT poovanishwetha comparisonofbiteforceandtheinfluencingfactorspreandpostcementationofstainlesssteelcrowninchildrenusingtscan AT thumatiprafulla comparisonofbiteforceandtheinfluencingfactorspreandpostcementationofstainlesssteelcrowninchildrenusingtscan |