Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading

BACKGROUND: The complications of implant-supported prostheses can be classified into mechanical and biological ones, one part of which is associated with screw loosening. This study was aimed to compare the effect of four different abutment screw torque techniques on screw loosening in single implan...

Descripción completa

Detalles Bibliográficos
Autores principales: Ebadian, Behnaz, Fathi, Amirhossein, Khodadad, Saba
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8315865/
https://www.ncbi.nlm.nih.gov/pubmed/34335769
http://dx.doi.org/10.1155/2021/3595064
_version_ 1783729788989472768
author Ebadian, Behnaz
Fathi, Amirhossein
Khodadad, Saba
author_facet Ebadian, Behnaz
Fathi, Amirhossein
Khodadad, Saba
author_sort Ebadian, Behnaz
collection PubMed
description BACKGROUND: The complications of implant-supported prostheses can be classified into mechanical and biological ones, one part of which is associated with screw loosening. This study was aimed to compare the effect of four different abutment screw torque techniques on screw loosening in single implant-supported prostheses following the application of mechanical loading. MATERIALS AND METHODS: In this experimental study, a total of 40 implants in acrylic blocks (6 × 10 × 20 mm) were mounted perpendicular to the surface. They were then randomly divided into four groups: (1) torquing once with 30 Ncm, (2) torquing three times with 30 Ncm and 5-minute intervals, (3) torquing once with 30 Ncm, opening the screw, and retorquing with 30 Ncm, and (4) torquing once with 35 Ncm. The torque values were confirmed by using a digital torque meter. Then, the samples underwent a force (2 cps, 0.453–11.793 kg) for three hours before the measurement of detorque values. The screw loosening force (torque) was then measured and recorded. The obtained data were analyzed by SPSS (version 22) software using one-way ANOVA and Tukey post hoc test at a 5% error level. RESULTS: The maximum mean detorque values of the abutment screws in single implant-supported prostheses were reported for groups 4 (27.8 ± 1.3), 1 (26.8 ± 1.3), and 3 (25.1 ± 1.3), and the minimum mean detorque value was found in group 2 (24.9 ± 1.2). Moreover, no significant difference was observed between groups 2 and 3 (p > 0.05), but a significant difference was found between groups 1 and 3 and other groups (p < 0.05). CONCLUSION: The increase in the torque value increased the torque loss. However, the detorque value in group 4 showed the least difference with the value recommended by the manufacturer (30 Ncm).
format Online
Article
Text
id pubmed-8315865
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-83158652021-07-31 Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading Ebadian, Behnaz Fathi, Amirhossein Khodadad, Saba Int J Dent Research Article BACKGROUND: The complications of implant-supported prostheses can be classified into mechanical and biological ones, one part of which is associated with screw loosening. This study was aimed to compare the effect of four different abutment screw torque techniques on screw loosening in single implant-supported prostheses following the application of mechanical loading. MATERIALS AND METHODS: In this experimental study, a total of 40 implants in acrylic blocks (6 × 10 × 20 mm) were mounted perpendicular to the surface. They were then randomly divided into four groups: (1) torquing once with 30 Ncm, (2) torquing three times with 30 Ncm and 5-minute intervals, (3) torquing once with 30 Ncm, opening the screw, and retorquing with 30 Ncm, and (4) torquing once with 35 Ncm. The torque values were confirmed by using a digital torque meter. Then, the samples underwent a force (2 cps, 0.453–11.793 kg) for three hours before the measurement of detorque values. The screw loosening force (torque) was then measured and recorded. The obtained data were analyzed by SPSS (version 22) software using one-way ANOVA and Tukey post hoc test at a 5% error level. RESULTS: The maximum mean detorque values of the abutment screws in single implant-supported prostheses were reported for groups 4 (27.8 ± 1.3), 1 (26.8 ± 1.3), and 3 (25.1 ± 1.3), and the minimum mean detorque value was found in group 2 (24.9 ± 1.2). Moreover, no significant difference was observed between groups 2 and 3 (p > 0.05), but a significant difference was found between groups 1 and 3 and other groups (p < 0.05). CONCLUSION: The increase in the torque value increased the torque loss. However, the detorque value in group 4 showed the least difference with the value recommended by the manufacturer (30 Ncm). Hindawi 2021-07-19 /pmc/articles/PMC8315865/ /pubmed/34335769 http://dx.doi.org/10.1155/2021/3595064 Text en Copyright © 2021 Behnaz Ebadian et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ebadian, Behnaz
Fathi, Amirhossein
Khodadad, Saba
Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
title Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
title_full Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
title_fullStr Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
title_full_unstemmed Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
title_short Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
title_sort comparison of the effect of four different abutment screw torques on screw loosening in single implant-supported prosthesis after the application of mechanical loading
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8315865/
https://www.ncbi.nlm.nih.gov/pubmed/34335769
http://dx.doi.org/10.1155/2021/3595064
work_keys_str_mv AT ebadianbehnaz comparisonoftheeffectoffourdifferentabutmentscrewtorquesonscrewlooseninginsingleimplantsupportedprosthesisaftertheapplicationofmechanicalloading
AT fathiamirhossein comparisonoftheeffectoffourdifferentabutmentscrewtorquesonscrewlooseninginsingleimplantsupportedprosthesisaftertheapplicationofmechanicalloading
AT khodadadsaba comparisonoftheeffectoffourdifferentabutmentscrewtorquesonscrewlooseninginsingleimplantsupportedprosthesisaftertheapplicationofmechanicalloading