Cargando…
Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR
BACKGROUND: Previous studies have stated that hyperventilation often occurs in cardiopulmonary resuscitation (CPR) mainly due to excessive ventilation frequencies, especially when a manual valve bag is used. Transport ventilators may provide mandatory ventilation with predetermined tidal volumes and...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8316711/ https://www.ncbi.nlm.nih.gov/pubmed/34321068 http://dx.doi.org/10.1186/s13049-021-00921-2 |
_version_ | 1783729919134531584 |
---|---|
author | Orlob, Simon Wittig, Johannes Hobisch, Christoph Auinger, Daniel Honnef, Gabriel Fellinger, Tobias Ristl, Robin Schindler, Otmar Metnitz, Philipp Feigl, Georg Prause, Gerhard |
author_facet | Orlob, Simon Wittig, Johannes Hobisch, Christoph Auinger, Daniel Honnef, Gabriel Fellinger, Tobias Ristl, Robin Schindler, Otmar Metnitz, Philipp Feigl, Georg Prause, Gerhard |
author_sort | Orlob, Simon |
collection | PubMed |
description | BACKGROUND: Previous studies have stated that hyperventilation often occurs in cardiopulmonary resuscitation (CPR) mainly due to excessive ventilation frequencies, especially when a manual valve bag is used. Transport ventilators may provide mandatory ventilation with predetermined tidal volumes and without the risk of hyperventilation. Nonetheless, interactions between chest compressions and ventilations are likely to occur. We investigated whether transport ventilators can provide adequate alveolar ventilation during continuous chest compression in adult CPR. METHODS: A three-period crossover study with three common transport ventilators in a cadaver model of CPR was carried out. The three ventilators ‘MEDUMAT Standard²’, ‘Oxylog 3000 plus’, and ‘Monnal T60’ represent three different interventions, providing volume-controlled continuous mandatory ventilation (VC-CMV) via an endotracheal tube with a tidal volume of 6 mL/kg predicted body weight. Proximal airflow was measured, and the net tidal volume was derived for each respiratory cycle. The deviation from the predetermined tidal volume was calculated and analysed. Several mixed linear models were calculated with the cadaver as a random factor and ventilator, height, sex, crossover period and incremental number of each ventilation within the period as covariates to evaluate differences between ventilators. RESULTS: Overall median deviation of net tidal volume from predetermined tidal volume was − 21.2 % (IQR: 19.6, range: [− 87.9 %; 25.8 %]) corresponding to a tidal volume of 4.75 mL/kg predicted body weight (IQR: 1.2, range: [0.7; 7.6]). In a mixed linear model, the ventilator model, the crossover period, and the cadaver’s height were significant factors for decreased tidal volume. The estimated effects of tidal volume deviation for each ventilator were − 14.5 % [95 %-CI: −22.5; −6.5] (p = 0.0004) for ‘Monnal T60’, − 30.6 % [95 %-CI: −38.6; −22.6] (p < 0.0001) for ‘Oxylog 3000 plus’ and − 31.0 % [95 %-CI: −38.9; −23.0] (p < 0.0001) for ‘MEDUMAT Standard²’. CONCLUSIONS: All investigated transport ventilators were able to provide alveolar ventilation even though chest compressions considerably decreased tidal volumes. Our results support the concept of using ventilators to avoid excessive ventilatory rates in CPR. This experimental study suggests that healthcare professionals should carefully monitor actual tidal volumes to recognise the occurrence of hypoventilation during continuous chest compressions. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13049-021-00921-2. |
format | Online Article Text |
id | pubmed-8316711 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-83167112021-07-28 Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR Orlob, Simon Wittig, Johannes Hobisch, Christoph Auinger, Daniel Honnef, Gabriel Fellinger, Tobias Ristl, Robin Schindler, Otmar Metnitz, Philipp Feigl, Georg Prause, Gerhard Scand J Trauma Resusc Emerg Med Original Research BACKGROUND: Previous studies have stated that hyperventilation often occurs in cardiopulmonary resuscitation (CPR) mainly due to excessive ventilation frequencies, especially when a manual valve bag is used. Transport ventilators may provide mandatory ventilation with predetermined tidal volumes and without the risk of hyperventilation. Nonetheless, interactions between chest compressions and ventilations are likely to occur. We investigated whether transport ventilators can provide adequate alveolar ventilation during continuous chest compression in adult CPR. METHODS: A three-period crossover study with three common transport ventilators in a cadaver model of CPR was carried out. The three ventilators ‘MEDUMAT Standard²’, ‘Oxylog 3000 plus’, and ‘Monnal T60’ represent three different interventions, providing volume-controlled continuous mandatory ventilation (VC-CMV) via an endotracheal tube with a tidal volume of 6 mL/kg predicted body weight. Proximal airflow was measured, and the net tidal volume was derived for each respiratory cycle. The deviation from the predetermined tidal volume was calculated and analysed. Several mixed linear models were calculated with the cadaver as a random factor and ventilator, height, sex, crossover period and incremental number of each ventilation within the period as covariates to evaluate differences between ventilators. RESULTS: Overall median deviation of net tidal volume from predetermined tidal volume was − 21.2 % (IQR: 19.6, range: [− 87.9 %; 25.8 %]) corresponding to a tidal volume of 4.75 mL/kg predicted body weight (IQR: 1.2, range: [0.7; 7.6]). In a mixed linear model, the ventilator model, the crossover period, and the cadaver’s height were significant factors for decreased tidal volume. The estimated effects of tidal volume deviation for each ventilator were − 14.5 % [95 %-CI: −22.5; −6.5] (p = 0.0004) for ‘Monnal T60’, − 30.6 % [95 %-CI: −38.6; −22.6] (p < 0.0001) for ‘Oxylog 3000 plus’ and − 31.0 % [95 %-CI: −38.9; −23.0] (p < 0.0001) for ‘MEDUMAT Standard²’. CONCLUSIONS: All investigated transport ventilators were able to provide alveolar ventilation even though chest compressions considerably decreased tidal volumes. Our results support the concept of using ventilators to avoid excessive ventilatory rates in CPR. This experimental study suggests that healthcare professionals should carefully monitor actual tidal volumes to recognise the occurrence of hypoventilation during continuous chest compressions. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13049-021-00921-2. BioMed Central 2021-07-28 /pmc/articles/PMC8316711/ /pubmed/34321068 http://dx.doi.org/10.1186/s13049-021-00921-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Original Research Orlob, Simon Wittig, Johannes Hobisch, Christoph Auinger, Daniel Honnef, Gabriel Fellinger, Tobias Ristl, Robin Schindler, Otmar Metnitz, Philipp Feigl, Georg Prause, Gerhard Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR |
title | Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR |
title_full | Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR |
title_fullStr | Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR |
title_full_unstemmed | Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR |
title_short | Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR |
title_sort | reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of cpr |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8316711/ https://www.ncbi.nlm.nih.gov/pubmed/34321068 http://dx.doi.org/10.1186/s13049-021-00921-2 |
work_keys_str_mv | AT orlobsimon reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT wittigjohannes reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT hobischchristoph reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT auingerdaniel reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT honnefgabriel reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT fellingertobias reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT ristlrobin reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT schindlerotmar reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT metnitzphilipp reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT feiglgeorg reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr AT prausegerhard reliabilityofmechanicalventilationduringcontinuouschestcompressionsacrossoverstudyoftransportventilatorsinahumancadavermodelofcpr |