Cargando…

Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging

Aim: This study aimed to evaluate the effect of polymerization with either a monowave (MW) or a polywave (PW) light-curing unit (LCU) on the degree of conversion (DC) and marginal adaptation following thermomechanical aging of an ormocer bulk-fill resin composite (RC) (Admira fusion X-tra Bulk Fill...

Descripción completa

Detalles Bibliográficos
Autores principales: Contreras, Sheila Celia Mondragón, Jurema, Ana Luiza Barbosa, Claudino, Evaniele Santos, Bresciani, Eduardo, Caneppele, Taciana Marco Ferraz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8317947/
https://www.ncbi.nlm.nih.gov/pubmed/34368776
http://dx.doi.org/10.1080/26415275.2021.1937181
_version_ 1783730154098393088
author Contreras, Sheila Celia Mondragón
Jurema, Ana Luiza Barbosa
Claudino, Evaniele Santos
Bresciani, Eduardo
Caneppele, Taciana Marco Ferraz
author_facet Contreras, Sheila Celia Mondragón
Jurema, Ana Luiza Barbosa
Claudino, Evaniele Santos
Bresciani, Eduardo
Caneppele, Taciana Marco Ferraz
author_sort Contreras, Sheila Celia Mondragón
collection PubMed
description Aim: This study aimed to evaluate the effect of polymerization with either a monowave (MW) or a polywave (PW) light-curing unit (LCU) on the degree of conversion (DC) and marginal adaptation following thermomechanical aging of an ormocer bulk-fill resin composite (RC) (Admira fusion X-tra Bulk Fill – AB), a methacrylate-based bulk-fill RC (Tetric N-Ceram Bulk Fill – TB) and a conventional RC (Tetric N-Ceram – TC). Methods: DC was assessed in five samples of each RC using Fourier transform infrared spectroscopy. For determination of marginal adaptation, standard preparations were made in 60 bovine incisors, divided into three groups, according to the RC. The bulk-fill RC was inserted in a single increment of 4 mm. In contrast, the conventional RC was inserted in three increments. Marginal gap was evaluated after thermomechanical aging. Data were analyzed using a two-way analysis of variance (ANOVA) and Tukey’s tests for multiple comparisons (α = 0.05). Results: The two-way ANOVA showed a significant effect (p<.05) of the RC factor but not of the LCU factor. The Tukey test showed that TB had the significantly lowest DC followed by TC, and with AB having the significantly highest DC. For the marginal adaptation, a significant effect was found for the LCU factor and the for the interaction RC × LCU (p<.05). Groups light-cured with PW showed significantly wider marginal gaps than MW. TC presented wider marginal gaps (17.36 µm) when cured with PW than when cured with MW (13.05 µm). The two bulk-fill RC resulted in similar marginal gap formation to each other. Conclusion: The ormocer-based bulk-fill RC showed a higher DC than the methacrylate-based bulk-fill RC but similar marginal adaptation. The LCU, MW or PW, had no significant influence on the DC, and no relevance on the marginal adaptation.
format Online
Article
Text
id pubmed-8317947
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-83179472021-08-06 Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging Contreras, Sheila Celia Mondragón Jurema, Ana Luiza Barbosa Claudino, Evaniele Santos Bresciani, Eduardo Caneppele, Taciana Marco Ferraz Biomater Investig Dent Research Article Aim: This study aimed to evaluate the effect of polymerization with either a monowave (MW) or a polywave (PW) light-curing unit (LCU) on the degree of conversion (DC) and marginal adaptation following thermomechanical aging of an ormocer bulk-fill resin composite (RC) (Admira fusion X-tra Bulk Fill – AB), a methacrylate-based bulk-fill RC (Tetric N-Ceram Bulk Fill – TB) and a conventional RC (Tetric N-Ceram – TC). Methods: DC was assessed in five samples of each RC using Fourier transform infrared spectroscopy. For determination of marginal adaptation, standard preparations were made in 60 bovine incisors, divided into three groups, according to the RC. The bulk-fill RC was inserted in a single increment of 4 mm. In contrast, the conventional RC was inserted in three increments. Marginal gap was evaluated after thermomechanical aging. Data were analyzed using a two-way analysis of variance (ANOVA) and Tukey’s tests for multiple comparisons (α = 0.05). Results: The two-way ANOVA showed a significant effect (p<.05) of the RC factor but not of the LCU factor. The Tukey test showed that TB had the significantly lowest DC followed by TC, and with AB having the significantly highest DC. For the marginal adaptation, a significant effect was found for the LCU factor and the for the interaction RC × LCU (p<.05). Groups light-cured with PW showed significantly wider marginal gaps than MW. TC presented wider marginal gaps (17.36 µm) when cured with PW than when cured with MW (13.05 µm). The two bulk-fill RC resulted in similar marginal gap formation to each other. Conclusion: The ormocer-based bulk-fill RC showed a higher DC than the methacrylate-based bulk-fill RC but similar marginal adaptation. The LCU, MW or PW, had no significant influence on the DC, and no relevance on the marginal adaptation. Taylor & Francis 2021-07-26 /pmc/articles/PMC8317947/ /pubmed/34368776 http://dx.doi.org/10.1080/26415275.2021.1937181 Text en © 2021 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Contreras, Sheila Celia Mondragón
Jurema, Ana Luiza Barbosa
Claudino, Evaniele Santos
Bresciani, Eduardo
Caneppele, Taciana Marco Ferraz
Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging
title Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging
title_full Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging
title_fullStr Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging
title_full_unstemmed Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging
title_short Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging
title_sort monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8317947/
https://www.ncbi.nlm.nih.gov/pubmed/34368776
http://dx.doi.org/10.1080/26415275.2021.1937181
work_keys_str_mv AT contrerassheilaceliamondragon monowaveandpolywavelightcuringofbulkfillresincompositesdegreeofconversionandmarginaladaptationfollowingthermomechanicalaging
AT juremaanaluizabarbosa monowaveandpolywavelightcuringofbulkfillresincompositesdegreeofconversionandmarginaladaptationfollowingthermomechanicalaging
AT claudinoevanielesantos monowaveandpolywavelightcuringofbulkfillresincompositesdegreeofconversionandmarginaladaptationfollowingthermomechanicalaging
AT brescianieduardo monowaveandpolywavelightcuringofbulkfillresincompositesdegreeofconversionandmarginaladaptationfollowingthermomechanicalaging
AT caneppeletacianamarcoferraz monowaveandpolywavelightcuringofbulkfillresincompositesdegreeofconversionandmarginaladaptationfollowingthermomechanicalaging