When Titans become weak: penile prosthesis cylinder aneurysm, a case report
During the first 5 years after penile prosthesis implantation, complications such as malfunction requiring revision or replacement occur in only 7% of cases. We present a case of a 62-year-old patient who had a Coloplast Titan(®) prosthesis implanted while also undergoing girth enhancement corporopl...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Polish Urological Association
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8318022/ https://www.ncbi.nlm.nih.gov/pubmed/34336247 http://dx.doi.org/10.5173/ceju.2021.0098 |
_version_ | 1783730169320570880 |
---|---|
author | Tavares, Catarina Djinovic, Rados Spiridonescu, Bogdan Guerra, Carlos Calleja Hermosa, Paola Sekulovic, Sasha |
author_facet | Tavares, Catarina Djinovic, Rados Spiridonescu, Bogdan Guerra, Carlos Calleja Hermosa, Paola Sekulovic, Sasha |
author_sort | Tavares, Catarina |
collection | PubMed |
description | During the first 5 years after penile prosthesis implantation, complications such as malfunction requiring revision or replacement occur in only 7% of cases. We present a case of a 62-year-old patient who had a Coloplast Titan(®) prosthesis implanted while also undergoing girth enhancement corporoplasty. Shortly after, the patient noticed an increasing bulge on the side of his penis, which prevented total deflation. An aneurysm of the right cylinder was identified during reoperation; cylinders were replaced and the redundant tunica albuginea and septal defect were corrected by plication from inside the corpora cavernosa. |
format | Online Article Text |
id | pubmed-8318022 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Polish Urological Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-83180222021-07-30 When Titans become weak: penile prosthesis cylinder aneurysm, a case report Tavares, Catarina Djinovic, Rados Spiridonescu, Bogdan Guerra, Carlos Calleja Hermosa, Paola Sekulovic, Sasha Cent European J Urol Case Report During the first 5 years after penile prosthesis implantation, complications such as malfunction requiring revision or replacement occur in only 7% of cases. We present a case of a 62-year-old patient who had a Coloplast Titan(®) prosthesis implanted while also undergoing girth enhancement corporoplasty. Shortly after, the patient noticed an increasing bulge on the side of his penis, which prevented total deflation. An aneurysm of the right cylinder was identified during reoperation; cylinders were replaced and the redundant tunica albuginea and septal defect were corrected by plication from inside the corpora cavernosa. Polish Urological Association 2021-05-10 2021 /pmc/articles/PMC8318022/ /pubmed/34336247 http://dx.doi.org/10.5173/ceju.2021.0098 Text en Copyright by Polish Urological Association https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Case Report Tavares, Catarina Djinovic, Rados Spiridonescu, Bogdan Guerra, Carlos Calleja Hermosa, Paola Sekulovic, Sasha When Titans become weak: penile prosthesis cylinder aneurysm, a case report |
title | When Titans become weak: penile prosthesis cylinder aneurysm, a case report |
title_full | When Titans become weak: penile prosthesis cylinder aneurysm, a case report |
title_fullStr | When Titans become weak: penile prosthesis cylinder aneurysm, a case report |
title_full_unstemmed | When Titans become weak: penile prosthesis cylinder aneurysm, a case report |
title_short | When Titans become weak: penile prosthesis cylinder aneurysm, a case report |
title_sort | when titans become weak: penile prosthesis cylinder aneurysm, a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8318022/ https://www.ncbi.nlm.nih.gov/pubmed/34336247 http://dx.doi.org/10.5173/ceju.2021.0098 |
work_keys_str_mv | AT tavarescatarina whentitansbecomeweakpenileprosthesiscylinderaneurysmacasereport AT djinovicrados whentitansbecomeweakpenileprosthesiscylinderaneurysmacasereport AT spiridonescubogdan whentitansbecomeweakpenileprosthesiscylinderaneurysmacasereport AT guerracarlos whentitansbecomeweakpenileprosthesiscylinderaneurysmacasereport AT callejahermosapaola whentitansbecomeweakpenileprosthesiscylinderaneurysmacasereport AT sekulovicsasha whentitansbecomeweakpenileprosthesiscylinderaneurysmacasereport |