Cargando…

Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering

3D volume rendering may represent a complementary option in the visualization of Digital Breast Tomosynthesis (DBT) examinations by providing an understanding of the underlying data at once. Rendering parameters directly influence the quality of rendered images. The purpose of this work is to study...

Descripción completa

Detalles Bibliográficos
Autores principales: Mota, Ana M., Clarkson, Matthew J., Almeida, Pedro, Matela, Nuno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321085/
https://www.ncbi.nlm.nih.gov/pubmed/34460657
http://dx.doi.org/10.3390/jimaging6070064
_version_ 1783730767813148672
author Mota, Ana M.
Clarkson, Matthew J.
Almeida, Pedro
Matela, Nuno
author_facet Mota, Ana M.
Clarkson, Matthew J.
Almeida, Pedro
Matela, Nuno
author_sort Mota, Ana M.
collection PubMed
description 3D volume rendering may represent a complementary option in the visualization of Digital Breast Tomosynthesis (DBT) examinations by providing an understanding of the underlying data at once. Rendering parameters directly influence the quality of rendered images. The purpose of this work is to study the influence of two of these parameters (voxel dimension in z direction and sampling distance) on DBT rendered data. Both parameters were studied with a real phantom and one clinical DBT data set. The voxel size was changed from 0.085 × 0.085 × 1.0 mm(3) to 0.085 × 0.085 × 0.085 mm(3) using ten interpolation functions available in the Visualization Toolkit library (VTK) and several sampling distance values were evaluated. The results were investigated at 90º using volume rendering visualization with composite technique. For phantom quantitative analysis, degree of smoothness, contrast-to-noise ratio, and full width at half maximum of a Gaussian curve fitted to the profile of one disk were used. Additionally, the time required for each visualization was also recorded. Hamming interpolation function presented the best compromise in image quality. The sampling distance values that showed a better balance between time and image quality were 0.025 mm and 0.05 mm. With the appropriate rendering parameters, a significant improvement in rendered images was achieved.
format Online
Article
Text
id pubmed-8321085
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83210852021-08-26 Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering Mota, Ana M. Clarkson, Matthew J. Almeida, Pedro Matela, Nuno J Imaging Article 3D volume rendering may represent a complementary option in the visualization of Digital Breast Tomosynthesis (DBT) examinations by providing an understanding of the underlying data at once. Rendering parameters directly influence the quality of rendered images. The purpose of this work is to study the influence of two of these parameters (voxel dimension in z direction and sampling distance) on DBT rendered data. Both parameters were studied with a real phantom and one clinical DBT data set. The voxel size was changed from 0.085 × 0.085 × 1.0 mm(3) to 0.085 × 0.085 × 0.085 mm(3) using ten interpolation functions available in the Visualization Toolkit library (VTK) and several sampling distance values were evaluated. The results were investigated at 90º using volume rendering visualization with composite technique. For phantom quantitative analysis, degree of smoothness, contrast-to-noise ratio, and full width at half maximum of a Gaussian curve fitted to the profile of one disk were used. Additionally, the time required for each visualization was also recorded. Hamming interpolation function presented the best compromise in image quality. The sampling distance values that showed a better balance between time and image quality were 0.025 mm and 0.05 mm. With the appropriate rendering parameters, a significant improvement in rendered images was achieved. MDPI 2020-07-04 /pmc/articles/PMC8321085/ /pubmed/34460657 http://dx.doi.org/10.3390/jimaging6070064 Text en © 2020 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Mota, Ana M.
Clarkson, Matthew J.
Almeida, Pedro
Matela, Nuno
Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering
title Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering
title_full Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering
title_fullStr Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering
title_full_unstemmed Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering
title_short Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering
title_sort optimization of breast tomosynthesis visualization through 3d volume rendering
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321085/
https://www.ncbi.nlm.nih.gov/pubmed/34460657
http://dx.doi.org/10.3390/jimaging6070064
work_keys_str_mv AT motaanam optimizationofbreasttomosynthesisvisualizationthrough3dvolumerendering
AT clarksonmatthewj optimizationofbreasttomosynthesisvisualizationthrough3dvolumerendering
AT almeidapedro optimizationofbreasttomosynthesisvisualizationthrough3dvolumerendering
AT matelanuno optimizationofbreasttomosynthesisvisualizationthrough3dvolumerendering