Cargando…

Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization

Over the last decade, the combination of compressed sensing (CS) with acquisition over multiple receiver coils in magnetic resonance imaging (MRI) has allowed the emergence of faster scans while maintaining a good signal-to-noise ratio (SNR). Self-calibrating techniques, such as ESPiRIT, have become...

Descripción completa

Detalles Bibliográficos
Autores principales: El Gueddari, Loubna, Giliyar Radhakrishna, Chaithya, Chouzenoux, Emilie, Ciuciu, Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321316/
https://www.ncbi.nlm.nih.gov/pubmed/34460714
http://dx.doi.org/10.3390/jimaging7030058
_version_ 1783730822572933120
author El Gueddari, Loubna
Giliyar Radhakrishna, Chaithya
Chouzenoux, Emilie
Ciuciu, Philippe
author_facet El Gueddari, Loubna
Giliyar Radhakrishna, Chaithya
Chouzenoux, Emilie
Ciuciu, Philippe
author_sort El Gueddari, Loubna
collection PubMed
description Over the last decade, the combination of compressed sensing (CS) with acquisition over multiple receiver coils in magnetic resonance imaging (MRI) has allowed the emergence of faster scans while maintaining a good signal-to-noise ratio (SNR). Self-calibrating techniques, such as ESPiRIT, have become the standard approach to estimating the coil sensitivity maps prior to the reconstruction stage. In this work, we proceed differently and introduce a new calibration-less multi-coil CS reconstruction method. Calibration-less techniques no longer require the prior extraction of sensitivity maps to perform multi-coil image reconstruction but usually alternate estimation sensitivity map estimation and image reconstruction. Here, to get rid of the nonconvexity of the latter approach we reconstruct as many MR images as the number of coils. To compensate for the ill-posedness of this inverse problem, we leverage structured sparsity of the multi-coil images in a wavelet transform domain while adapting to variations in SNR across coils owing to the OSCAR (octagonal shrinkage and clustering algorithm for regression) regularization. Coil-specific complex-valued MR images are thus obtained by minimizing a convex but nonsmooth objective function using the proximal primal-dual Condat-Vù algorithm. Comparison and validation on retrospective Cartesian and non-Cartesian studies based on the Brain fastMRI data set demonstrate that the proposed reconstruction method outperforms the state-of-the-art ([Formula: see text]-ESPIRiT, calibration-less AC-LORAKS and CaLM methods) significantly on magnitude images for the T1 and FLAIR contrasts. Additionally, further validation operated on 8 to 20-fold prospectively accelerated high-resolution ex vivo human brain MRI data collected at 7 Tesla confirms the retrospective results. Overall, OSCAR-based regularization preserves phase information more accurately (both visually and quantitatively) compared to other approaches, an asset that can only be assessed on real prospective experiments.
format Online
Article
Text
id pubmed-8321316
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83213162021-08-26 Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization El Gueddari, Loubna Giliyar Radhakrishna, Chaithya Chouzenoux, Emilie Ciuciu, Philippe J Imaging Article Over the last decade, the combination of compressed sensing (CS) with acquisition over multiple receiver coils in magnetic resonance imaging (MRI) has allowed the emergence of faster scans while maintaining a good signal-to-noise ratio (SNR). Self-calibrating techniques, such as ESPiRIT, have become the standard approach to estimating the coil sensitivity maps prior to the reconstruction stage. In this work, we proceed differently and introduce a new calibration-less multi-coil CS reconstruction method. Calibration-less techniques no longer require the prior extraction of sensitivity maps to perform multi-coil image reconstruction but usually alternate estimation sensitivity map estimation and image reconstruction. Here, to get rid of the nonconvexity of the latter approach we reconstruct as many MR images as the number of coils. To compensate for the ill-posedness of this inverse problem, we leverage structured sparsity of the multi-coil images in a wavelet transform domain while adapting to variations in SNR across coils owing to the OSCAR (octagonal shrinkage and clustering algorithm for regression) regularization. Coil-specific complex-valued MR images are thus obtained by minimizing a convex but nonsmooth objective function using the proximal primal-dual Condat-Vù algorithm. Comparison and validation on retrospective Cartesian and non-Cartesian studies based on the Brain fastMRI data set demonstrate that the proposed reconstruction method outperforms the state-of-the-art ([Formula: see text]-ESPIRiT, calibration-less AC-LORAKS and CaLM methods) significantly on magnitude images for the T1 and FLAIR contrasts. Additionally, further validation operated on 8 to 20-fold prospectively accelerated high-resolution ex vivo human brain MRI data collected at 7 Tesla confirms the retrospective results. Overall, OSCAR-based regularization preserves phase information more accurately (both visually and quantitatively) compared to other approaches, an asset that can only be assessed on real prospective experiments. MDPI 2021-03-19 /pmc/articles/PMC8321316/ /pubmed/34460714 http://dx.doi.org/10.3390/jimaging7030058 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
El Gueddari, Loubna
Giliyar Radhakrishna, Chaithya
Chouzenoux, Emilie
Ciuciu, Philippe
Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization
title Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization
title_full Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization
title_fullStr Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization
title_full_unstemmed Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization
title_short Calibration-Less Multi-Coil Compressed Sensing Magnetic Resonance Image Reconstruction Based on OSCAR Regularization
title_sort calibration-less multi-coil compressed sensing magnetic resonance image reconstruction based on oscar regularization
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321316/
https://www.ncbi.nlm.nih.gov/pubmed/34460714
http://dx.doi.org/10.3390/jimaging7030058
work_keys_str_mv AT elgueddariloubna calibrationlessmulticoilcompressedsensingmagneticresonanceimagereconstructionbasedonoscarregularization
AT giliyarradhakrishnachaithya calibrationlessmulticoilcompressedsensingmagneticresonanceimagereconstructionbasedonoscarregularization
AT chouzenouxemilie calibrationlessmulticoilcompressedsensingmagneticresonanceimagereconstructionbasedonoscarregularization
AT ciuciuphilippe calibrationlessmulticoilcompressedsensingmagneticresonanceimagereconstructionbasedonoscarregularization