Cargando…

Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup

Graphical visualization systems are a common clinical tool for displaying digital images and three-dimensional volumetric data. These systems provide a broad spectrum of information to support physicians in their clinical routine. For example, the field of radiology enjoys unrestricted options for i...

Descripción completa

Detalles Bibliográficos
Autores principales: Wachter, Andreas, Kost, Jan, Nahm, Werner
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321353/
https://www.ncbi.nlm.nih.gov/pubmed/34460683
http://dx.doi.org/10.3390/jimaging7050087
_version_ 1783730832477782016
author Wachter, Andreas
Kost, Jan
Nahm, Werner
author_facet Wachter, Andreas
Kost, Jan
Nahm, Werner
author_sort Wachter, Andreas
collection PubMed
description Graphical visualization systems are a common clinical tool for displaying digital images and three-dimensional volumetric data. These systems provide a broad spectrum of information to support physicians in their clinical routine. For example, the field of radiology enjoys unrestricted options for interaction with the data, since information is pre-recorded and available entirely in digital form. However, some fields, such as microsurgery, do not benefit from this yet. Microscopes, endoscopes, and laparoscopes show the surgical site as it is. To allow free data manipulation and information fusion, 3D digitization of surgical sites is required. We aimed to find the number of cameras needed to add this functionality to surgical microscopes. For this, we performed in silico simulations of the 3D reconstruction of representative models of microsurgical sites with different numbers of cameras in narrow-baseline setups. Our results show that eight independent camera views are preferable, while at least four are necessary for a digital surgical site. In most cases, eight cameras allow the reconstruction of over 99% of the visible part. With four cameras, still over 95% can be achieved. This answers one of the key questions for the development of a prototype microscope. In future, such a system can provide functionality which is unattainable today.
format Online
Article
Text
id pubmed-8321353
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83213532021-08-26 Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup Wachter, Andreas Kost, Jan Nahm, Werner J Imaging Article Graphical visualization systems are a common clinical tool for displaying digital images and three-dimensional volumetric data. These systems provide a broad spectrum of information to support physicians in their clinical routine. For example, the field of radiology enjoys unrestricted options for interaction with the data, since information is pre-recorded and available entirely in digital form. However, some fields, such as microsurgery, do not benefit from this yet. Microscopes, endoscopes, and laparoscopes show the surgical site as it is. To allow free data manipulation and information fusion, 3D digitization of surgical sites is required. We aimed to find the number of cameras needed to add this functionality to surgical microscopes. For this, we performed in silico simulations of the 3D reconstruction of representative models of microsurgical sites with different numbers of cameras in narrow-baseline setups. Our results show that eight independent camera views are preferable, while at least four are necessary for a digital surgical site. In most cases, eight cameras allow the reconstruction of over 99% of the visible part. With four cameras, still over 95% can be achieved. This answers one of the key questions for the development of a prototype microscope. In future, such a system can provide functionality which is unattainable today. MDPI 2021-05-13 /pmc/articles/PMC8321353/ /pubmed/34460683 http://dx.doi.org/10.3390/jimaging7050087 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wachter, Andreas
Kost, Jan
Nahm, Werner
Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup
title Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup
title_full Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup
title_fullStr Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup
title_full_unstemmed Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup
title_short Simulation-Based Estimation of the Number of Cameras Required for 3D Reconstruction in a Narrow-Baseline Multi-Camera Setup
title_sort simulation-based estimation of the number of cameras required for 3d reconstruction in a narrow-baseline multi-camera setup
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321353/
https://www.ncbi.nlm.nih.gov/pubmed/34460683
http://dx.doi.org/10.3390/jimaging7050087
work_keys_str_mv AT wachterandreas simulationbasedestimationofthenumberofcamerasrequiredfor3dreconstructioninanarrowbaselinemulticamerasetup
AT kostjan simulationbasedestimationofthenumberofcamerasrequiredfor3dreconstructioninanarrowbaselinemulticamerasetup
AT nahmwerner simulationbasedestimationofthenumberofcamerasrequiredfor3dreconstructioninanarrowbaselinemulticamerasetup