In this work, novel denoising and super resolution (SR) approaches for magnetic resonance (MR) images are addressed, and are integrated in a unified framework, which do not require example low resolution (LR)/high resolution (HR)/cross-modality/noise-free images and prior information of noise–noise...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaur, Prabhjot, Sao, Anil Kumar, Ahuja, Chirag Kamal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321357/
http://dx.doi.org/10.3390/jimaging7060101
_version_ 1783730833419403264
author Kaur, Prabhjot
Sao, Anil Kumar
Ahuja, Chirag Kamal
author_facet Kaur, Prabhjot
Sao, Anil Kumar
Ahuja, Chirag Kamal
author_sort Kaur, Prabhjot
collection PubMed
description In this work, novel denoising and super resolution (SR) approaches for magnetic resonance (MR) images are addressed, and are integrated in a unified framework, which do not require example low resolution (LR)/high resolution (HR)/cross-modality/noise-free images and prior information of noise–noise variance. The proposed method categorizes the patches as either smooth or textured and then denoises them by deploying different denoising strategies for efficient denoising. The denoising algorithm is integrated into the SR approach, which uses a gradient profile-based constraint in a sparse representation-based framework to improve the resolution of MR images with reduced smearing of image details. This constraint regularizes the estimation of HR images such that the estimated HR image has gradient profiles similar to the gradient profiles of the original HR image. For this, the gradient profile sharpness (GPS) values of an unknown HR image are estimated using an approximated piece-wise linear relation among GPS values of LR and upsampled LR images. The experiments are performed on three different publicly available datasets. The proposed SR approach outperforms the existing unsupervised SR approach addressed for real MR images that exploits low rank and total variation (LRTV) regularization, by an average peak signal to noise ratio (PSNR) of 0.73 dB and 0.38 dB for upsampling factors 2 and 3, respectively. For the super resolution of noisy real MR images (degraded with 2% noise), the proposed approach outperforms the LRTV approach by an average PSNR of 0.54 dB and 0.46 dB for upsampling factors 2 and 3, respectively. The qualitative analysis is shown for real MR images from healthy subjects and subjects with Alzheimer’s disease and structural deformity, i.e., cavernoma.
format Online
Article
Text
id pubmed-8321357
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83213572021-08-26 Super Resolution of Magnetic Resonance Images Kaur, Prabhjot Sao, Anil Kumar Ahuja, Chirag Kamal J Imaging Article In this work, novel denoising and super resolution (SR) approaches for magnetic resonance (MR) images are addressed, and are integrated in a unified framework, which do not require example low resolution (LR)/high resolution (HR)/cross-modality/noise-free images and prior information of noise–noise variance. The proposed method categorizes the patches as either smooth or textured and then denoises them by deploying different denoising strategies for efficient denoising. The denoising algorithm is integrated into the SR approach, which uses a gradient profile-based constraint in a sparse representation-based framework to improve the resolution of MR images with reduced smearing of image details. This constraint regularizes the estimation of HR images such that the estimated HR image has gradient profiles similar to the gradient profiles of the original HR image. For this, the gradient profile sharpness (GPS) values of an unknown HR image are estimated using an approximated piece-wise linear relation among GPS values of LR and upsampled LR images. The experiments are performed on three different publicly available datasets. The proposed SR approach outperforms the existing unsupervised SR approach addressed for real MR images that exploits low rank and total variation (LRTV) regularization, by an average peak signal to noise ratio (PSNR) of 0.73 dB and 0.38 dB for upsampling factors 2 and 3, respectively. For the super resolution of noisy real MR images (degraded with 2% noise), the proposed approach outperforms the LRTV approach by an average PSNR of 0.54 dB and 0.46 dB for upsampling factors 2 and 3, respectively. The qualitative analysis is shown for real MR images from healthy subjects and subjects with Alzheimer’s disease and structural deformity, i.e., cavernoma. MDPI 2021-06-21 /pmc/articles/PMC8321357/ http://dx.doi.org/10.3390/jimaging7060101 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kaur, Prabhjot
Sao, Anil Kumar
Ahuja, Chirag Kamal
Super Resolution of Magnetic Resonance Images
title Super Resolution of Magnetic Resonance Images
title_full Super Resolution of Magnetic Resonance Images
title_fullStr Super Resolution of Magnetic Resonance Images
title_full_unstemmed Super Resolution of Magnetic Resonance Images
title_short Super Resolution of Magnetic Resonance Images
title_sort super resolution of magnetic resonance images
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321357/
http://dx.doi.org/10.3390/jimaging7060101
work_keys_str_mv AT kaurprabhjot superresolutionofmagneticresonanceimages
AT saoanilkumar superresolutionofmagneticresonanceimages
AT ahujachiragkamal superresolutionofmagneticresonanceimages