Cargando…
Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights
OBJECTIVE: To study and analyze the changes of intervertebral foramen height and area of the degenerative L4-5 intervertebral disc under different pushing heights by the finite element method. METHODS: CT and MRI images of T12-S1 segments were obtained from a healthy volunteer who met the inclusion...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321728/ https://www.ncbi.nlm.nih.gov/pubmed/34336148 http://dx.doi.org/10.1155/2021/1322397 |
_version_ | 1783730913740324864 |
---|---|
author | Ding, Huaili Liao, Lijun Yan, Peichun Zhao, Xiaolin Li, Min |
author_facet | Ding, Huaili Liao, Lijun Yan, Peichun Zhao, Xiaolin Li, Min |
author_sort | Ding, Huaili |
collection | PubMed |
description | OBJECTIVE: To study and analyze the changes of intervertebral foramen height and area of the degenerative L4-5 intervertebral disc under different pushing heights by the finite element method. METHODS: CT and MRI images of T12-S1 segments were obtained from a healthy volunteer who met the inclusion criteria. A DR machine was used to capture images of the lumbar lateral section before and after simultaneous pushing of the L4 and L5 spinous processes by manipulation called Daogaijinbei, and the measurement showed that the displacement changes of L4 and L5 were both approximately 10 cm, so the pushing height was set at 0–10 cm. A three-dimensional finite element model of the entire normal lumbar spine was established using Mimics 16.0, Geomagic Studio 2014, Hypermesh 13.0, MSC.Patran 2012, and so on. The disc height and nucleus area of the lumbar disc of the normal entire lumbar disc model were adjusted to establish models of the L4-5 disc with mild, moderate, and severe degeneration. Changes of disc height and area of the L4-5 degenerative intervertebral disc under different pushing heights were calculated. RESULTS: The size of the L4-5 intervertebral foramen was analyzed from the height and area of the intervertebral foramen, and the results showed the following: (1) as for the normal lumbar disc and a lumbar of the L4-5 disc with mild and moderate degeneration, the height of the L4-5 intervertebral foramen and its area both increased during pushing between 0 and 8 cm. After the pushing height reached 8 cm, the height and area of the L4-5 intervertebral foramen gradually became stable; (2) as for the L4-5 disc with severe degeneration, during the process of pushing, the height and area of the L4-5 intervertebral foramen increased slightly, but this change was not obvious. CONCLUSIONS: After the spinal manipulation, the sizes of the L4-5 intervertebral foramen of the L4-5 disc with mild and moderate degeneration were significantly larger than those before pushing; in contrast, the size of L4-5 intervertebral foramen of the L4-5 disc with severe lumbar degeneration was not significantly changed. |
format | Online Article Text |
id | pubmed-8321728 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-83217282021-07-31 Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights Ding, Huaili Liao, Lijun Yan, Peichun Zhao, Xiaolin Li, Min J Healthc Eng Research Article OBJECTIVE: To study and analyze the changes of intervertebral foramen height and area of the degenerative L4-5 intervertebral disc under different pushing heights by the finite element method. METHODS: CT and MRI images of T12-S1 segments were obtained from a healthy volunteer who met the inclusion criteria. A DR machine was used to capture images of the lumbar lateral section before and after simultaneous pushing of the L4 and L5 spinous processes by manipulation called Daogaijinbei, and the measurement showed that the displacement changes of L4 and L5 were both approximately 10 cm, so the pushing height was set at 0–10 cm. A three-dimensional finite element model of the entire normal lumbar spine was established using Mimics 16.0, Geomagic Studio 2014, Hypermesh 13.0, MSC.Patran 2012, and so on. The disc height and nucleus area of the lumbar disc of the normal entire lumbar disc model were adjusted to establish models of the L4-5 disc with mild, moderate, and severe degeneration. Changes of disc height and area of the L4-5 degenerative intervertebral disc under different pushing heights were calculated. RESULTS: The size of the L4-5 intervertebral foramen was analyzed from the height and area of the intervertebral foramen, and the results showed the following: (1) as for the normal lumbar disc and a lumbar of the L4-5 disc with mild and moderate degeneration, the height of the L4-5 intervertebral foramen and its area both increased during pushing between 0 and 8 cm. After the pushing height reached 8 cm, the height and area of the L4-5 intervertebral foramen gradually became stable; (2) as for the L4-5 disc with severe degeneration, during the process of pushing, the height and area of the L4-5 intervertebral foramen increased slightly, but this change was not obvious. CONCLUSIONS: After the spinal manipulation, the sizes of the L4-5 intervertebral foramen of the L4-5 disc with mild and moderate degeneration were significantly larger than those before pushing; in contrast, the size of L4-5 intervertebral foramen of the L4-5 disc with severe lumbar degeneration was not significantly changed. Hindawi 2021-07-19 /pmc/articles/PMC8321728/ /pubmed/34336148 http://dx.doi.org/10.1155/2021/1322397 Text en Copyright © 2021 Huaili Ding et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ding, Huaili Liao, Lijun Yan, Peichun Zhao, Xiaolin Li, Min Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights |
title | Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights |
title_full | Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights |
title_fullStr | Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights |
title_full_unstemmed | Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights |
title_short | Three-Dimensional Finite Element Analysis of L4-5 Degenerative Lumbar Disc Traction under Different Pushing Heights |
title_sort | three-dimensional finite element analysis of l4-5 degenerative lumbar disc traction under different pushing heights |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8321728/ https://www.ncbi.nlm.nih.gov/pubmed/34336148 http://dx.doi.org/10.1155/2021/1322397 |
work_keys_str_mv | AT dinghuaili threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights AT liaolijun threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights AT yanpeichun threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights AT zhaoxiaolin threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights AT limin threedimensionalfiniteelementanalysisofl45degenerativelumbardisctractionunderdifferentpushingheights |