Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation

BACKGROUND: Accurate implant impression is an essential requirement for the fabrication of implant prosthesis. This in vitro study evaluated the accuracy of digital impressions by intraoral scanner (IOS) systems in comparison to conventional impressions for recording the position of 2 parallel impla...

Descripción completa

Detalles Bibliográficos
Autores principales: Abduo, Jaafar, Palamara, Joseph E. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8322372/
https://www.ncbi.nlm.nih.gov/pubmed/34327601
http://dx.doi.org/10.1186/s40729-021-00355-6
_version_ 1783731035171717120
author Abduo, Jaafar
Palamara, Joseph E. A.
author_facet Abduo, Jaafar
Palamara, Joseph E. A.
author_sort Abduo, Jaafar
collection PubMed
description BACKGROUND: Accurate implant impression is an essential requirement for the fabrication of implant prosthesis. This in vitro study evaluated the accuracy of digital impressions by intraoral scanner (IOS) systems in comparison to conventional impressions for recording the position of 2 parallel implants and 2 divergent implants. MATERIALS AND METHODS: In vitro 3-unit prosthesis master models with 2 tissue level implants were fabricated; one model had parallel implants, and the other model had one 15° tilted implant. The conventional open-tray impressions were obtained with non-splinted (NSP) and splinted (SP) impression copings. Trios 4 (TS), Medit i500 (MT), and True Definition (TD) were used to make digital impressions with scan bodies. A total of 10 impressions were obtained with every technique. The virtual test images of the conventional and digital impressions were converted to 2 virtual implant images. For each group, trueness, precision, inter-implant distance deviation, and angle deviation were measured. RESULTS: There was a general tendency for digital impressions to provide a more accurate outcome for trueness, precision, and angle deviation. The 2 conventional impressions showed similar accuracy, except for the angle deviation, where the NSP was significantly inferior than SP (p < 0.01) for the divergent implants model. The TD was generally the least accurate among all the IOS systems, especially for the inter-implant distance deviation (p < 0.05). CONCLUSIONS: Within the limitations of the laboratory set-up of the present study and the limited clinical resemblance, the digital impressions appeared to have sufficient accuracy for 2 implants and were least affected by the presence of angle between implants. The most inferior outcome was observed for the NSP technique.
format Online
Article
Text
id pubmed-8322372
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-83223722021-08-19 Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation Abduo, Jaafar Palamara, Joseph E. A. Int J Implant Dent Research BACKGROUND: Accurate implant impression is an essential requirement for the fabrication of implant prosthesis. This in vitro study evaluated the accuracy of digital impressions by intraoral scanner (IOS) systems in comparison to conventional impressions for recording the position of 2 parallel implants and 2 divergent implants. MATERIALS AND METHODS: In vitro 3-unit prosthesis master models with 2 tissue level implants were fabricated; one model had parallel implants, and the other model had one 15° tilted implant. The conventional open-tray impressions were obtained with non-splinted (NSP) and splinted (SP) impression copings. Trios 4 (TS), Medit i500 (MT), and True Definition (TD) were used to make digital impressions with scan bodies. A total of 10 impressions were obtained with every technique. The virtual test images of the conventional and digital impressions were converted to 2 virtual implant images. For each group, trueness, precision, inter-implant distance deviation, and angle deviation were measured. RESULTS: There was a general tendency for digital impressions to provide a more accurate outcome for trueness, precision, and angle deviation. The 2 conventional impressions showed similar accuracy, except for the angle deviation, where the NSP was significantly inferior than SP (p < 0.01) for the divergent implants model. The TD was generally the least accurate among all the IOS systems, especially for the inter-implant distance deviation (p < 0.05). CONCLUSIONS: Within the limitations of the laboratory set-up of the present study and the limited clinical resemblance, the digital impressions appeared to have sufficient accuracy for 2 implants and were least affected by the presence of angle between implants. The most inferior outcome was observed for the NSP technique. Springer Berlin Heidelberg 2021-07-30 /pmc/articles/PMC8322372/ /pubmed/34327601 http://dx.doi.org/10.1186/s40729-021-00355-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Abduo, Jaafar
Palamara, Joseph E. A.
Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
title Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
title_full Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
title_fullStr Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
title_full_unstemmed Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
title_short Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
title_sort accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8322372/
https://www.ncbi.nlm.nih.gov/pubmed/34327601
http://dx.doi.org/10.1186/s40729-021-00355-6
work_keys_str_mv AT abduojaafar accuracyofdigitalimpressionsversusconventionalimpressionsfor2implantsaninvitrostudyevaluatingtheeffectofimplantangulation
AT palamarajosephea accuracyofdigitalimpressionsversusconventionalimpressionsfor2implantsaninvitrostudyevaluatingtheeffectofimplantangulation