Cargando…
Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure
There are numerous arthroscopic techniques available to address anterior shoulder instability. Complications are various, and in pursuit of new treatment options, an alternative arthroscopic technique with less potential for complications has been developed. The novel subscapular sling with a semite...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8322630/ https://www.ncbi.nlm.nih.gov/pubmed/34336575 http://dx.doi.org/10.1016/j.eats.2021.03.027 |
_version_ | 1783731092414529536 |
---|---|
author | Klungsøyr, Jan Arild Vagstad, Terje Klungsøyr, Peter Johannes Hellevik, Alf Inge Drogset, Jon Olav |
author_facet | Klungsøyr, Jan Arild Vagstad, Terje Klungsøyr, Peter Johannes Hellevik, Alf Inge Drogset, Jon Olav |
author_sort | Klungsøyr, Jan Arild |
collection | PubMed |
description | There are numerous arthroscopic techniques available to address anterior shoulder instability. Complications are various, and in pursuit of new treatment options, an alternative arthroscopic technique with less potential for complications has been developed. The novel subscapular sling with a semitendinosus graft provides both dynamic and static stability. This procedure uses a semitendinosus graft as a sling around the upper two-thirds of the subscapular tendon, attached to the anterior glenoid rim. The sling phenomenon present in the Latarjet procedure was the basis of the development. The efficacy of the subscapular sling procedure has been verified in biomechanical studies and further investigated in a clinical pilot study. The procedure can be performed without altering the anatomy of nearby structures such as the coracoid process, the conjoined tendon, and the axillary and musculocutaneous nerves. The authors propose the arthroscopic subscapular sling procedure as an alternative to existing surgical treatment options for recurrent anterior shoulder instability. |
format | Online Article Text |
id | pubmed-8322630 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-83226302021-07-31 Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure Klungsøyr, Jan Arild Vagstad, Terje Klungsøyr, Peter Johannes Hellevik, Alf Inge Drogset, Jon Olav Arthrosc Tech Technical Note There are numerous arthroscopic techniques available to address anterior shoulder instability. Complications are various, and in pursuit of new treatment options, an alternative arthroscopic technique with less potential for complications has been developed. The novel subscapular sling with a semitendinosus graft provides both dynamic and static stability. This procedure uses a semitendinosus graft as a sling around the upper two-thirds of the subscapular tendon, attached to the anterior glenoid rim. The sling phenomenon present in the Latarjet procedure was the basis of the development. The efficacy of the subscapular sling procedure has been verified in biomechanical studies and further investigated in a clinical pilot study. The procedure can be performed without altering the anatomy of nearby structures such as the coracoid process, the conjoined tendon, and the axillary and musculocutaneous nerves. The authors propose the arthroscopic subscapular sling procedure as an alternative to existing surgical treatment options for recurrent anterior shoulder instability. Elsevier 2021-06-20 /pmc/articles/PMC8322630/ /pubmed/34336575 http://dx.doi.org/10.1016/j.eats.2021.03.027 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Technical Note Klungsøyr, Jan Arild Vagstad, Terje Klungsøyr, Peter Johannes Hellevik, Alf Inge Drogset, Jon Olav Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure |
title | Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure |
title_full | Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure |
title_fullStr | Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure |
title_full_unstemmed | Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure |
title_short | Dynamic and Static Stabilization of Anterior Shoulder Instability With the Subscapular Sling Procedure |
title_sort | dynamic and static stabilization of anterior shoulder instability with the subscapular sling procedure |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8322630/ https://www.ncbi.nlm.nih.gov/pubmed/34336575 http://dx.doi.org/10.1016/j.eats.2021.03.027 |
work_keys_str_mv | AT klungsøyrjanarild dynamicandstaticstabilizationofanteriorshoulderinstabilitywiththesubscapularslingprocedure AT vagstadterje dynamicandstaticstabilizationofanteriorshoulderinstabilitywiththesubscapularslingprocedure AT klungsøyrpeterjohannes dynamicandstaticstabilizationofanteriorshoulderinstabilitywiththesubscapularslingprocedure AT hellevikalfinge dynamicandstaticstabilizationofanteriorshoulderinstabilitywiththesubscapularslingprocedure AT drogsetjonolav dynamicandstaticstabilizationofanteriorshoulderinstabilitywiththesubscapularslingprocedure |