Cargando…

Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center

Objective: Flow diverter (FD) stents have become one of the most common tools for treating intracranial aneurysms; however, their role in treating posterior circulation aneurysms is still discussed with controversy. In this study, we evaluated the safety and effectiveness of p64 FD for the treatment...

Descripción completa

Detalles Bibliográficos
Autores principales: Hellstern, Victoria, Aguilar-Pérez, Marta, Henkes, Elina, Serna-Candel, Carmen, Wendl, Christina, Bäzner, Hansjörg, Ganslandt, Oliver, Henkes, Hans
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8322946/
https://www.ncbi.nlm.nih.gov/pubmed/34335461
http://dx.doi.org/10.3389/fneur.2021.711863
_version_ 1783731148795412480
author Hellstern, Victoria
Aguilar-Pérez, Marta
Henkes, Elina
Serna-Candel, Carmen
Wendl, Christina
Bäzner, Hansjörg
Ganslandt, Oliver
Henkes, Hans
author_facet Hellstern, Victoria
Aguilar-Pérez, Marta
Henkes, Elina
Serna-Candel, Carmen
Wendl, Christina
Bäzner, Hansjörg
Ganslandt, Oliver
Henkes, Hans
author_sort Hellstern, Victoria
collection PubMed
description Objective: Flow diverter (FD) stents have become one of the most common tools for treating intracranial aneurysms; however, their role in treating posterior circulation aneurysms is still discussed with controversy. In this study, we evaluated the safety and effectiveness of p64 FD for the treatment of saccular, unruptured aneurysms in the posterior circulation over a long-term follow-up period in a single center. Methods: From our prospectively maintained database, we retrospectively identified patients who underwent treatment of an intracranial saccular aneurysm arising from the posterior circulation with ≥1 p64 FD implanted or attempted between October 2012 and December 2019. Aneurysms could have been treated with prior or concomitant saccular treatment (e.g., coiling, intra-aneurysmal flow diversion). Aneurysms with parent vessel implants other than p64, fusiform aneurysms, and dissections were excluded. Peri- and postprocedural complications, clinical outcome, and clinical and angiographic follow-up results were evaluated. Results: In total, 54 patients (45 female, 9 male; mean age 55.1 years) with 54 intracranial aneurysms met the inclusion criteria. In 51 cases (94.4%), one p64 was implanted; in 2 cases (3.7 %), two p64s were implanted; in one case, deployment of the p64 was not feasible. Procedural complications occurred in 3.7% and postprocedural complications in 9.3 %, respectively. Hemorrhagic complications occurred in 2/54 patients (3.7%), thereof one fatal parenchymal hemorrhage. Ischemic complications were observed in 5/54 patients (9.3%). Early, mid-term, and long-term angiographic follow-up examinations showed complete or near-complete aneurysm occlusion, defined according to the O'Kelly –Marotta (OKM) scale as OKM C + D in 56, 75.6, and 82.9 %, respectively. Asymptomatic side vessel occlusions occurred in 3.8%, each during the first follow-up. Conclusions: The implantation of a p64 FD is a safe and effective device for endovascular treatment of posterior circulation saccular aneurysms with a high success rate and low morbi-mortality.
format Online
Article
Text
id pubmed-8322946
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-83229462021-07-31 Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center Hellstern, Victoria Aguilar-Pérez, Marta Henkes, Elina Serna-Candel, Carmen Wendl, Christina Bäzner, Hansjörg Ganslandt, Oliver Henkes, Hans Front Neurol Neurology Objective: Flow diverter (FD) stents have become one of the most common tools for treating intracranial aneurysms; however, their role in treating posterior circulation aneurysms is still discussed with controversy. In this study, we evaluated the safety and effectiveness of p64 FD for the treatment of saccular, unruptured aneurysms in the posterior circulation over a long-term follow-up period in a single center. Methods: From our prospectively maintained database, we retrospectively identified patients who underwent treatment of an intracranial saccular aneurysm arising from the posterior circulation with ≥1 p64 FD implanted or attempted between October 2012 and December 2019. Aneurysms could have been treated with prior or concomitant saccular treatment (e.g., coiling, intra-aneurysmal flow diversion). Aneurysms with parent vessel implants other than p64, fusiform aneurysms, and dissections were excluded. Peri- and postprocedural complications, clinical outcome, and clinical and angiographic follow-up results were evaluated. Results: In total, 54 patients (45 female, 9 male; mean age 55.1 years) with 54 intracranial aneurysms met the inclusion criteria. In 51 cases (94.4%), one p64 was implanted; in 2 cases (3.7 %), two p64s were implanted; in one case, deployment of the p64 was not feasible. Procedural complications occurred in 3.7% and postprocedural complications in 9.3 %, respectively. Hemorrhagic complications occurred in 2/54 patients (3.7%), thereof one fatal parenchymal hemorrhage. Ischemic complications were observed in 5/54 patients (9.3%). Early, mid-term, and long-term angiographic follow-up examinations showed complete or near-complete aneurysm occlusion, defined according to the O'Kelly –Marotta (OKM) scale as OKM C + D in 56, 75.6, and 82.9 %, respectively. Asymptomatic side vessel occlusions occurred in 3.8%, each during the first follow-up. Conclusions: The implantation of a p64 FD is a safe and effective device for endovascular treatment of posterior circulation saccular aneurysms with a high success rate and low morbi-mortality. Frontiers Media S.A. 2021-07-16 /pmc/articles/PMC8322946/ /pubmed/34335461 http://dx.doi.org/10.3389/fneur.2021.711863 Text en Copyright © 2021 Hellstern, Aguilar-Pérez, Henkes, Serna-Candel, Wendl, Bäzner, Ganslandt and Henkes. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Hellstern, Victoria
Aguilar-Pérez, Marta
Henkes, Elina
Serna-Candel, Carmen
Wendl, Christina
Bäzner, Hansjörg
Ganslandt, Oliver
Henkes, Hans
Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center
title Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center
title_full Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center
title_fullStr Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center
title_full_unstemmed Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center
title_short Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center
title_sort endovascular treatment of posterior circulation saccular aneurysms with the p64 flow modulation device: mid-and long-term results in 54 aneurysms from a single center
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8322946/
https://www.ncbi.nlm.nih.gov/pubmed/34335461
http://dx.doi.org/10.3389/fneur.2021.711863
work_keys_str_mv AT hellsternvictoria endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter
AT aguilarperezmarta endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter
AT henkeselina endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter
AT sernacandelcarmen endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter
AT wendlchristina endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter
AT baznerhansjorg endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter
AT ganslandtoliver endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter
AT henkeshans endovasculartreatmentofposteriorcirculationsaccularaneurysmswiththep64flowmodulationdevicemidandlongtermresultsin54aneurysmsfromasinglecenter